Search PubMed⌕ Search

PubMed · 9857745

Three dimensional echocardiography.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F J Pinto, F Veiga, M G Lopes, F de Pádua. 1998. Three dimensional echocardiography.. https://pubmed.ncbi.nlm.nih.gov/9857745/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Left ventricular endocardial surface detection based on real-time 3D echocardiographic data.

OBJECTIVE: A new computerized semi-automatic method for left ventricular (LV) chamber segmentation is presented. METHODS: The LV is imaged by real-time three-dimensional echocardiography (RT3DE). The surface detection model, based on level set techniques, is applied to RT3DE data for image analysis. The modified level set partial differential equation we use is solved by applying numerical methods for conservation laws. The initial conditions are manually established on some slices of the entire volume. The solution obtained for each slice is a contour line corresponding with the boundary between LV cavity and LV endocardium. RESULTS: The mathematical model has been applied to sequences of frames of human hearts (volume range: 34-109 ml) imaged by 2D and reconstructed off-line and RT3DE data. Volume estimation obtained by this new semi-automatic method shows an excellent correlation with those obtained by manual tracing (r = 0.992). Dynamic change of LV volume during the cardiac cycle is also obtained. CONCLUSION: The volume estimation method is accurate; edge based segmentation, image completion and volume reconstruction can be accomplished. The visualization technique also allows to navigate into the reconstructed volume and to display any section of the volume.

Echocardiography, Three-Dimensional↗

Real-time three-dimensional echocardiography in assessment of heart disease.

Echocardiography has progressed at an impressive pace in the last decade. A plethora of new techniques, including tissue-Doppler imaging, harmonic imaging, contrast echocardiography, digital-stress echocardiography, and three-dimensional (3-D) echocardiography, have altered our diagnostic strategies for managing patients with heart disease. Until recently, 3-D echocardiography was looked upon as a time-consuming and tedious procedure, making it more a research interest than a diagnostic tool. The introduction of real-time three-dimensional (RT-3-D) echocardiography has made possible dynamic diagnostic/therapeutic assessments while the procedure is performed. At The University of Texas Medical Branch in Galveston, Texas, our more than 2 years of experience with RT-3-D suggests that this technique will play an important role in diagnosing and managing patients with heart disease.

Echocardiography, Three-Dimensional↗

In vitro measurement accuracy of three-dimensional ultrasound.

OBJECTIVES: We sought to validate distance and volume measurements in three-dimensional (3-D) ultrasound images. BACKGROUND: Even with the latest equipment, it is not known how accurate 3-D echocardiographic measurements are. METHODS: Six models were imaged in ethanol solution and two within a tissue phantom using a mechanical rotation device rotating in 1 degrees intervals and a real-time 3-D scanner. Distance and volume measurements (n = 60) were performed in two-dimensional (2-D) and 3-D images using TomTec and InViVo software. RESULTS: Distance measurements had a mean total error between 1.12% and 2.31% for Acuson (2.5 MHZ, 3 MHZ, and 4 MHZ) and Hewlett Parkard (HP) fusion frequencies h and m, HP fusion harmonic B in the axial, and between 3.5% and 4.9% in the lateral dimension. HP Harmonic A and B, Volumetrics (2.5 MHZ), and HP fusion Harmonic A exhibited significantly higher differences to reality with a mean difference between 5.1% and 8.9% in the axial and between 6.2% and 7.9% in the lateral direction. Axial 2-D measurements were not different from real dimensions except Volumetrics model 1. In the lateral axis, all imaging modalities were different from reality except the fusion harmonic modus B. Using the HP fusion frequency h and HP fusion Harmonic B-mode, volume measurements in 3-D images significantly underestimated reality, while Acuson's fundamental frequency 3.5 MHZ was not different from real volumes. CONCLUSION: Three-dimensional visualization using different ultrasound settings results in different accuracy.

Echocardiography, Three-Dimensional↗