Search PubMed⌕ Search

Biomedical subjects

F J Pinto

Publications and source records attributed to F J Pinto.

At least 19 recordsLinked to original sources

[Endovascular treatment of aneurysms of the descending thoracic aorta--a new therapeutic perspective].

Endovascular treatment of aneurysmal disease of descending thoracic aorta and infra-renal abdominal aorta, has become an accepted technique, in selected cases due to the reduction of neurological morbidity, paraparesis or paraplegic and renal ischemia, associated with conventional surgery. The authors describe the first case performed in Portugal of a 75-year-old female with an expanding thoracic aneurysm managed by endovascular exclusion of the aneurysm with an EXCLUDER endoprosthesis, without any complications or evidence of endoleak, achieving complete exclusion of the aneurysm.

Aged↗

Dynamic three-dimensional reconstruction of the heart by transesophageal echocardiography.

OBJECTIVE: To evaluate echocardiography accuracy in performing and obtaining images for dynamical three-dimensional (3D) reconstruction. METHODS: Three-dimensional (3D) image reconstruction was obtained in 20 consecutive patients who underwent transesophageal echocardiography. A multiplanar 5 MHz transducer was used for 3D reconstruction. RESULTS: Twenty patients were studied consecutively. The following cardiac diseases were present: valvar prostheses--6 (2 mitral, 2 aortic and 2 mitral and aortic); mitral valve prolapse--3; mitral and aortic disease--2; aortic valve disease--5; congenital heart disease--3 (2 atrial septal defect--ASD- and 1 transposition of the great arteries-TGA); arteriovenous fistula--1. In 7 patients, color Doppler was also obtained and used for 3D flow reconstruction. Twenty five cardiac structures were acquired and 60 reconstructions generated (28 of mitral valves, 14 of aortic valves, 4 of mitral prostheses, 7 of aortic prostheses and 7 of the ASD). Fifty five of 60 (91.6%) reconstructions were considered of good quality by 2 independent observers. The 11 reconstructed mitral valves/prostheses and the 2 reconstructed ASDs provided more anatomical information than two dimensional echocardiography (2DE) alone. CONCLUSION: 3D echocardiography using a transesophageal transducer is a feasible technique, which improves detection of anatomical details of cardiac structures, particularly of the mitral valve and atrial septum.

Adult↗

The value of intravascular ultrasound in interventional cardiology.

Intracoronary ultrasound (ICUS) is a new imaging technique with the unique ability to study vessel wall morphology in vivo, accurately displaying the details of vessel structure. The coronary angiogram represents only a projectional image of the vessel lumen without providing any information concerning vascular wall architecture. Interventional cardiology has developed over the last years with the appearance of new devices and consequently new challenges. The selection of an appropriate device and the assessment of any intervention, as well as the understanding of its mechanisms is essential to perform a better intervention. The use of a tool, such as ICUS, able to identify vessel wall anomalies, complementing coronary angiography, seems to be an appropriate method in the regard. The last years have witnessed an array of studies demonstrating the advantages and disadvantages of ICUS in the setting of interventional cardiology. Despite some contradictions in the literature, the result of a new technology still under scrutiny, it is possible to summarise some of the major achievements: Lesion assessment before coronary interventions for selection of treatment, including calcium detection, plaque eccentricity, diffuse atherosclerotic disease, type of vessel remodelling; ICUS during balloon angioplasty has helped in balloon diameter selection, identification of pseudo successful results and presence/severity of wall dissections, as well as the search of predictors of restenosis; during rotational and directional atherectomy, ICUS can help in the definition of the lesion most suitable for rotational atherectomy, showing if there is a diffuse sub endothelial calcification, excluding unsuitable lesions, selecting cut direction and directly assessing the adequacy of plaque removal; during stent implantation it helps to determine if there was a complete apposition, detect residual narrowing or proximal/distal stenoses or dissections requiring further treatment. Some new concepts have been introduced by ICUS, such as the negative remodelling as one of the mechanisms of restenosis. New developments are under way, including combined devices, looking forward ultrasound, high frequency probes, imaging wires, tissue characterisation and three dimensional technology. Therefore, ICUS has reached enough maturity to be considered an important tool in the catheterization laboratory, complementing the information provided by coronary angiography. However, some more research needs to be done to answer some important questions regarding the whole array of potential applications in an environment of cost containment as the one we live in today.

Angioplasty, Balloon, Coronary↗

[The Internet as a solution facilitating the identification of patients with a suspected acute myocardial infarct].

The current steps for diagnosing heart disease are very time consuming, delaying the correct identification of the problem, therefore, delaying the right treatment. In this study we have developed an experimental method using e-mail in order to identify patients with "rule out myocardial" condition and reduce the time lag for thrombolysis or coronary angioplasty in this clinical setting. Three different locations linked to the Internet by ISDN lines were used. Each line was connected with a computer. A pager and a dedicated phone line were also used. The following steps were performed for each situation: filling out of a questionnaire, ECG recording, questionnaire mailing and ECG by e-mail as attachment, pager warning that an urgent cardiology consultation was requested, including the doctor and patient's phone number, time to open the message and reply by e-mail, phone call for additional comments. A total of 24 attempts of interactive communication were performed. In 22 of those, an answer was obtained in less than 30 minutes. Two failures were recorded. One was due to a delay in the pager message, which did not arrive within the first hour; the second was due to a computer break down. This report shows that it is possible to establish a fast communication between the out patient clinic and the hospital (less than 30 minutes in most cases) at a very low cost and in a simple manner.

Costs and Cost Analysis↗

Experimental design approach for the optimization of supercritical fluid extraction of chlorophenols from polluted soils.

Supercritical fluid extraction and liquid chromatography-electrochemical detection (LC-ECD) were used to the determination of chlorophenols in contaminated soil samples. Full factorial design experiments were used in order to optimize the extraction parameters: pressure, extraction cell temperature and percentage of modifier. Pressure and percentage of modifier (methanol) had statistically significant effects on the recovery of the chlorophenols. Good repeatability (4.9-11.8%) and reproducibility (4.9-12.5%) were achieved and low detection limits (3-150 ng g-1) were obtained. The method was validated by comparing the results with those obtained in a European intercomparison exercise.

Chlorophenols↗

Dynamic three-dimensional echocardiography: a new era in ultrasound technology.

The use of noninvasive methods to visualise the heart has had an extraordinary development over the last decade, with echocardiography demonstrating a particularly fast growth. Despite its unquestionable role in the diagnosis of heart disease and in the management of cardiac patients, it does have some limitations, both in the morphological visualisation, as well as in the functional assessment of the heart, such as blood flow, quantification of intracardiac volumes, etc. The recent development of dynamic three-dimensional (3D) echocardiography from two dimensional images has opened new perspectives in the study of cardiac pathophysiology. There are basically two methods of displaying three dimensional data sets: (1) a two-dimensional display from individual selected cut planes (any-plane echocardiography) or from parallel short axis cuts; (2) a volume rendered technique: from any defined cut plane, different algorithms are applied to represent the information in space. There are several potential clinical applications of 3D such as the measurement and serial follow-up of left ventricular volumes; in valvular heart disease (the abnormalities can be delineated more precisely and in greater detail than conventional imaging, including a detailed definition of mitral apparatus in mitral stenosis), in mitral valve prolapse both leaflets can be seen from the left atrial view and in endocarditis it can aid in deciding when and how to intervene; in complex congenital heart disease, such as reconstruction of double outlet right ventricle, left-sided obstructive and regurgitant lesions and subaortic obstructive cases, in atrial and ventricular septal defects, displaying size, geometry and relationships to other structures; another expression of cardiac disorders are blood flow disturbances (visualisation of flows in 3D could allow a better qualitative and quantitative assessment of their size and severity; the pictures so far generated allow a good perception of the size and shape of mitral, aortic and tricuspid regurgitation jets, by examining them from a new perspective, it also has the potential to display the flow convergence zone and quantify the regurgitant volume). Recent studies have clearly demonstrated the feasibility of performing three-dimensional imaging in a variety of cardiac diseases, but continued development of ultrasound technology must be made to improve better image resolution. The prolonged acquisition time is the most important limiting factor that currently restricts the routine use of 3D echocardiography. The development of faster computers will shorten the time needed for image acquisition, postprocessing, and data analysis, contributing to the goal of easy access and wide use. With improvements in computer technology and production of interactive software, 3D echocardiography will provide a dynamic view of the surgical anatomy of the heart. Thus, the three-dimensional reconstruction concept has the potential to and diagnostic assessment of cardiac pathology in every facet.

Cardiovascular Diseases↗

Coronary artery intimal thickening in the transplanted heart. An in vivo intracoronary untrasound study of immunologic and metabolic risk factors.

This study examined the hypothesis that immunologic factors are the major correlates of coronary artery intimal thickening and luminal stenosis. The study population included 116 adult heart transplant recipients with a mean age of 44.7 +/- 12.0 years (89 men and 27 women) undergoing annual coronary angiography and intracoronary ultrasound 3.4 +/- 2.7 (range, 1.0-14.6) years after transplantation. Mean intimal thickness was obtained from several distinct sites along the left anterior descending and/or left circumflex coronary artery by intracoronary ultrasound. Coronary artery stenosis defined by angiography was classified as mild (< 30% luminal stenosis), moderate (> or = 30-70% luminal stenosis), or severe (> 70% luminal stenosis or diffuse pruning of distal vessels). Prevalence of any transplant coronary artery disease (TxCAD) was 85% by intracoronary ultrasound and 15% by angiography. By multiple regression analysis, only average fasting plasma triglyceride level (P < 0.006) and average weight (P < 0.007) were significantly correlated with severity of intimal thickening (R = 0.54, P < 0.0001). Donor age (P < 0.006) and average fasting plasma triglyceride level (P < 0.009) were significantly correlated with stenosis by angiography. Correlation of multiple immunologic and metabolic factors with intimal thickness by univariate analysis suggests a multifactorial etiology for TxCAD. Among the multiple univariate correlates of TxCAD, higher fasting plasma triglyceride levels and body weight are the only independent correlates of TxCAD. The absence of acute rejection as an independent predictor of intimal thickening suggests that mechanisms beyond those mediating typical cellular rejection should be targeted for advancing our understanding of Tx-CAD.

Adult↗

Prediction of angiographic disease by intracoronary ultrasonographic findings in heart transplant recipients.

BACKGROUND: Intracoronary ultrasonography has proven to be a more sensitive test than angiography for the detection of intimal thickening in transplant recipients. However, the prognostic significance of the intimal thickening detected by intracoronary ultrasonography has not been proven. METHOD: During a 1-year period, 70 transplant recipients without angiographically apparent coronary artery disease underwent intracoronary ultrasonography examination. For each intracoronary ultrasonography study an intimal index, defined as the ratio of the plaque area to the area within the media, was measured for the most diseased segment imaged. The subsequent annual follow-up angiograms of these 70 patients were reviewed for the development of visually apparent coronary artery disease. The time since transplantation for the 70 patients without angiographically apparent coronary artery disease ranged from 1 to 15 years, with a mean of 4.2 years an median of 3.9 years. Mean duration of angiographic follow-up was 2.0 years (range 1 to 3 years). RESULTS: Angiographically apparent coronary artery disease developed on follow-up angiograms in 13 of the 70 patients, with a mean time to development of 1.5 years. Four of 46 patients (9%) with an intimal index < 0.3 subsequently had angiographically apparent coronary artery disease, whereas of 25 patients (36%) with an intimal index > or = 0.3 subsequently had angiographically apparent coronary artery disease. Odds ratio for future angiographically apparent coronary artery disease between patients with an intimal index > or = and intimal index < 0.3 was 5.9 (p < 0.01 by Fisher's Exact test). In a subgroup of 22 patients more than 5 years after transplantation at the time of intracoronary ultrasonography, 12 had an intimal index < 0.3 and 10 had an intimal index > or = 0.3. In this subgroup none of the 12 patients with an intimal index < 0.3 had angiographically apparent coronary artery disease and only 1 of the 10 with an intimal index > or = 0.3 had angiographically apparent coronary artery disease (difference not significant). CONCLUSIONS: The presence of moderate to severe intimal thickening by intracoronary ultrasonography is predictive of the future development of angiographically apparent coronary artery disease among patients more than 1 year and less than 5 years after transplantation. This same degree of intimal thickening may not carry the same prognostic significance among patients greater than 5 years after transplantation without the development of angiographically apparent coronary artery disease.

Adult↗

Prognostic importance of intimal thickness as measured by intracoronary ultrasound after cardiac transplantation.

BACKGROUND: Although intracoronary ultrasound (ICUS) has been validated for the early detection of transplant coronary artery disease (TxCAD), the prognostic importance of findings detected by this new imaging technique is unknown. METHODS AND RESULTS: This study examined the relation of clinical outcome in 145 heart transplant recipients (mean age, 45.1 +/- 11.1 years) with the amount of intimal thickness measured by ICUS during routine annual coronary angiography 1 to 10 years (mean, 3.1 +/- 2.2 years) after transplantation. From published autopsy data, a mean intimal thickness of > 0.3 mm was considered significant. During a mean follow-up time of 48.2 +/- 10.2 months, 23 deaths (12 cardiac) occurred, and 6 patients required retransplantation. Angiographic TxCAD developed in 22 of 125 patients (17.6%) in the subgroup with normal angiograms at the time of ICUS and a follow-up annual angiographic study. In the total population and the subgroup, mean intimal thicknesses of > 0.3 and < or = 0.3 mm, respectively, were associated with significantly inferior 4-year actuarial overall survival (73% versus 96%, P = .005; 72% versus 92%, P = .05), cardiac survival (79% versus 96%, P = .005; 80% versus 98%, P = .04), and freedom from cardiac death and retransplantation (74% versus 98%, P < .0001; 70% versus 96%, P = .001). In addition, ICUS predicted freedom from development of subsequent angiographic TxCAD in the subgroup that was initially normal (26% versus 72%, P = .02). A mean intimal thickness by ICUS of > 0.3 mm was associated with inferior clinical outcome regardless of the presence of angiographic TxCAD and predicted the development of subsequent angiographic TxCAD. Despite significantly longer duration after transplantation, higher rejection incidence, and lower average daily cyclosporine dose, none of these covariates were independent risk factors for outcome. CONCLUSIONS: These findings confirm the prognostic importance of mean intimal thickening of > 0.3 mm in heart transplant recipients and suggest that these patients should be candidates for early interventional strategies.

Coronary Disease↗

Influence of preexistent donor coronary artery disease on the progression of transplant vasculopathy. An intravascular ultrasound study.

BACKGROUND: Transplant vasculopathy (TxCAD) limits longterm survival of allograft recipients. The possibility that preexistent donor coronary disease (PEDD) might accelerate this process is of concern. The serial progression of sites with and without PEDD as assessed by intravascular ultrasonic imaging is explored in this study. METHODS AND RESULTS: Thirty patients with baseline intravascular imaging within 3 weeks of cardiac transplantation who had at least one annual follow-up study were included in this study. Vessel luminal area (LA), total area (TA), intimal index (II = TA - LA/TA), mean intimal thickness (MIT), and Stanford classification were expressed for each image site and for each patient at each study. Progression of sites and of patients with and without PEDD on the baseline study was compared. Patients with PEDD (n = 9) still had significantly more intimal disease than those without PEDD (n = 21) at the first follow-up study (MIT = 0.35 +/- 0.13 versus 0.13 +/- 0.11 mm; II = 0.29 +/- 0.11 versus 0.11 +/- 0.1; class = 3.7 +/- 0.5 versus 2.2 +/- 0.94; P < .001 for all comparisons). However, the increase in intimal thickness during the 1- year interval was not significantly different between the two groups. In 4 patients in whom both types of sites were present, no difference in progression was found. Data were similar for patients and sites studied over > 1 year. CONCLUSIONS: PEDD does not accelerate the progression of TxCAD within the first few years after cardiac transplantation. The pathophysiology of TxCAD is most likely immune mediated and does not seem to be accelerated by native coronary artery disease.

Adult↗

Correlation of donor characteristics with transplant coronary artery disease as assessed by intracoronary ultrasound and coronary angiography.

The mechanisms responsible for transplant coronary artery disease (CAD) and its predisposing factors remain incompletely understood. The influence of donor characteristics as predisposing factors has not been studied systematically. We examined the correlation of donor demographic, clinical, and immunologic parameters with transplant CAD assessed by both intracoronary ultrasound (ICUS) and coronary angiography in 116 heart transplant recipients (age 44.7 +/- 12.0 years) studied 3.4 years (range 1.0 to 14.6) after transplantation. Quantitative ultrasound data were obtained by calculating mean intimal thickness from several distinct coronary sites. Coronary angiograms were categorized visually as normal or showing any transplant CAD. By multivariate regression analysis, donor undersize of > 20% of recipient weight (p < 0.02) and duration after transplantation (p < 0.005) were independently correlated with the amount of ICUS intimal thickness (r = 0.36, p = 0.0007), and older donor age with angiographic evidence for the disease (r = 0.34, p < 0.006). In a subgroup analysis of the 39 patients studied 1 year after transplantation, white donor race (p < 0.05), fewer human leukocyte antigen-DR mismatches (p < 0.002), shorter ischemic time (p < 0.04), and donor smoking history (p < 0.02) were independent predictors for severity of ICUS intimal thickening (r = 0.92, p = 0.0009); higher donor age (p < 0.006) and higher arterial partial pressure of oxygen (p < 0.003) were independent predictors for angiographic disease (r = 0.67, p < 0.002). In conclusion, donor characteristics may contribute to the probably multifactorial pathogenesis of transplant CAD.

Adult↗