Radial echo-planar imaging.

Abstract

A new ultrafast magnetic resonance imaging pulse sequence named radial echo-planar imaging (rEPI) is introduced. The sequence is based on a modification of the echo-planar imaging (EPI) sequence to scan k-space radially, in an attempt to combine the speed of EPI with the benefits of radial sampling. Like in EPI, all the desired lines in k-space are scanned consecutively in opposite directions. The unique feature of this new sequence, however, is that the orientation of the readout gradient is incrementally rotated, so that all the echoes are refocused through the center of k-space. Therefore, rEPI data are acquired in a polar grid, and image reconstruction can be done either by means of filtered back-projection or by regridding the data to a Cartesian matrix followed by 2D Fourier transform. First results show that rEPI images can be acquired with the same speed and signal-to-noise ratio of EPI images. rEPI images are also shown to be less sensitive to off-resonance effects than EPI images. Further studies are underway to investigate the usefulness of rEPI for spectroscopic imaging and applications affected by motion.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A C Silva, E L Barbier, I J Lowe, A P Koretsky. 1998. Radial echo-planar imaging.. https://doi.org/10.1006/jmre.1998.1547

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimization of fast cardiac imaging using an echo-train readout.

Fast gradient-echo sequences that use an echo-train readout are becoming more widely used, particularly for imaging the heart. An important issue for these sequences involves determining the optimal duration for the echo-train readout. In normal volunteer scans and theoretically the echo-train readout duration was varied from 2.4 to 32.8 msec. Myocardial signal-to-noise ratio (SNR), myocardium-tag signal difference-to-noise ratio (SDNR), flow artifact-to-noise ratio (FNR), and geometric distortion were measured and/or calculated. Our results showed that to obtain high SNR, SDNR, and data acquisition efficiency while minimizing FNR and geometric distortion, the readout duration should be 10-15 msec at 1.5 T.

Echo-Planar Imaging↗

Magnetic resonance imaging of ultrasound fields: gradient characteristics.

Phase-contrast magnetic resonance imaging (MRI) is used to image particle displacements arising from a 0.515-MHZ focused ultrasound (US) field. The technique used a phase-locked, self-resonant gradient matched to the US frequency in conjunction with a spin-echo sequence to generate phase images of US-induced displacement parallel to the US propagation direction. The gradient design was numerically optimized to provide maximum linearity and magnitude while minimizing gradient inductance. The windings were fabricated of Litz wire to minimize resistive losses and mounted in an oil-cooled imaging chamber. When driven by a resonance power supply, a peak magnetic field gradient of 0.40 T/m was attained with a peak current of 20 amp in a volume of 53 cm(3), achieving stable oscillation at the required US frequency. Clear detection of the nanometer scale particle motions of the US field was achieved and allowed quantitative, noninvasive visualization of the entire US field. While the required gradient slew rate for US detection is beyond that recommended for in vivo application, this imaging method opens new possibilities for in vitro or ex vivo research in the study of the interaction of US with tissue.

Echo-Planar Imaging↗

Field mapping without reference scan using asymmetric echo-planar techniques.

Improvements in Bo mapping and shimming were achieved by measuring the static field information in multiple subsequent echoes generated by an asymmetric echo-planar readout gradient train. With careful compensation, eddy current effects were shown to affect the adjustment of the shim coils minimally. In addition to reducing the time required for field mapping by two-fold, the sensitivity was simultaneously optimized irrespective of the prevalent T2* present, thereby minimizing the error of the static field measurement to below 0.1 Hz. With adiabatic low flip-angle excitation, the time required for field mapping was below 1 second.

Echo-Planar Imaging↗