Search PubMedSearch

PubMed · 9686027

[Rotatory impulse test does not replace caloric tests].

Abstract

We sought to determine whether the rotatory impulsional test was capable of exploring the canalar function with sufficient precision to replace the caloric test, as it has been recently affirmed. We first compared the observed preponderance from this test with that measured during a sinusoidal (20 and 4 s) test. We observed that, in the case of a significant preponderance for a given test, there was complete redondance with the preponderance observed with any other test. The rotatory impulsional test does not present any specific advantage compared to other kinetic test as far as the observation of the preponderance phenomenon. We then compared the preponderance with the results of the caloric tests and came to the following conclusions i) the absence of preponderance does not allow us to predict the absence of vestibular deficit, due to the fact that 37% of the deficits were compensated for including acoustic neuroma; ii) the presence of a preponderance does not allow a priori to say whether it is of vestibular, cervical, or central origin and systematic caloric tests shows that almost one fourth of preponderance observed is not associated with unilateral weakness iii) supposing that a clinical argument allow us to conclude as to the probable vestibular origin of a vestibular preponderance, the direction of this preponderance does not allow us to determine which side is involved. In fact, if the undercompensated deficits are 3 times more frequent than overcompensated deficits, the proportion of preponderance not linked to a significant deficit indicates that the probability of encountering a preponderance related to a specific undercompensated deficit is approximately 50%. We thus did not find in the rotatory impulsional test any specific advantage allowing us to predict the laterality of a vestibular lesion.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E Ulmer, P Herman, M Toupet, A Gentine, M Negrevergne, J Boussens, R Duclaux, R Biboulet, M J Estève-Fraysse, G Dumas, S Tronche, P T Huy. 1997. [Rotatory impulse test does not replace caloric tests].. https://pubmed.ncbi.nlm.nih.gov/9686027/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Electronystagmographic changes in patients with unilateral vestibular schwannomas in relation to tumor progression and central compensation.

Vestibular function was studied in a group of 121 patients with unilateral vestibular schwannomas who were referred to University Hospital Utrecht between 1986 and 1996. Testing included the caloric test, torsion test, saccade test, smooth pursuit test and the registration of spontaneous nystagmus. Each patient's symptoms were taken from a chart review. The size of the tumor was expressed as the maximum extrameatal diameter in the axial plane parallel to the petrous ridge as seen in magnetic resonance imaging or computed tomography. Large tumors were significantly more often accompanied by a more severe paresis on caloric testing, a smaller gain on torsion testing, spontaneous nystagmus, an abnormal saccade test and an abnormal smooth pursuit test. The presence of spontaneous nystagmus was significantly more frequently combined with an abnormal smooth pursuit and saccade test. There was a significant correlation between the slow component's velocity of the spontaneous nystagmus and the size and progression of tumor. However, a specific relation between tumor size and central vestibular compensation could not be demonstrated.

Caloric Tests

Caloric value of inulin and oligofructose.

Dietary carbohydrates, which are absorbed as hexose, (glucose, fructose) have a caloric value of 3.9 kcal/g (16.3 kJ/g), and their cellular metabolism produces approximately 38 mol ATP/mol. However, chicory inulin and oligofructose resist digestion and they are not absorbed in the upper part of the gastrointestinal tract. After oral ingestion, they reach the colon intact where they become hydrolyzed and extensively fermented by saccharolytic bacteria, which produce short-chain carboxylic and lactic acids as electron sinks. Depending on both the degree of their colonic fermentation and the assumptions of the model used, the caloric value of such nondigested but fermented carbohydrates varies between 0 and 2.5 kcal/g. Through the catabolism of the absorbed short-chain carboxylic and lactic acids, they may produce up to 17 mol ATP/mol of fermented sugar moiety. Because the daily intake of these dietary carbohydrates is likely to remain relatively small (<10% and probably often not >5% of total daily calorie intake), it is of low relevance nutritionally to give them a precise caloric value. On the basis of biochemical balance charts for carbon atoms, metabolic pathways and energy yields to the host, the caloric value of a fructosyl residue in chicory inulin and oligofructose has been calculated to be approximately 25-35% that of a fully digested and absorbed fructose molecule. For the purpose of food labeling, it is recommended that chicory inulin and oligofructose, like all the other carbohydrates that are more or less completely fermented in the human colon, should be given a caloric value of 1.5 kcal/g (6.3 kJ/g).

Caloric Tests