Discrepancies between sizer and valve dimensions: implications for small aortic root.

Abstract

BACKGROUND: Precise labeling of sizer and valve diameters is crucial for optimal valve selection especially in the small aortic root. This study examines the accuracy of manufacturers' markings on small aortic prostheses and sizers. METHODS: Sizer and valve dimensions of 22 different mechanical aortic prostheses (19 to 23 mm) were evaluated by caliper micrometer measurements. RESULTS: Nearly all sizers exceeded their marked dimensions by up to 1.0 mm. Measured tissue annulus diameters for 19-mm-labeled valves varied between 18.3 and 19.6 mm, for 21-mm valves from 20.5 to 21.6 mm, and for 23-mm valves from 22.4 to 23.5 mm, respectively. The orifice areas ranged from 1.5 to 2.06 cm2 for 19-mm valves, from 2.0 to 2.55 cm2 for 21-mm valves, and from 2.4 to 3.09 cm2 for 23-mm valves, respectively. CONCLUSIONS: Actual sizer dimensions and tissue annulus diameters of various small mechanical aortic prostheses varied considerably from their marked diameters. These differences should be considered to ensure the optimal prosthesis selection for each patient.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Bartels, R G Leyh, J F Matthias Bechtel, E Joubert-Hübner, H H Sievers. 1998. Discrepancies between sizer and valve dimensions: implications for small aortic root.. https://doi.org/10.1016/s0003-4975(98)00225-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Right-sided vegetation unmasks aortic endocarditis.

Echocardiography is a key tool in the diagnosis of infective endocarditis. Although transthoracic echocardiography is the first step in the work-up, transoesophageal echocardiography is mandatory for the evaluation of the exact extent of the infectious process. Indeed, perivalvular abscess can fistulate towards different heart chambers, leading sometimes to critical clinical situations.

Aortic Valve↗

Aortic translocation for the management of transposition of the great arteries with a ventricular septal defect, pulmonary stenosis, and hypoplasia of the right ventricle.

A 2-month-old patient with transposition of the great arteries, a ventricular septal defect, pulmonary stenosis, and severe hypoplasia of the right ventricle successfully underwent a biventricular repair utilizing the aortic translocation technique. Advantages of this surgical repair over the Rastelli procedure in the management of this complex congenital heart lesion are discussed.

Aortic Valve↗

Evidence in favor of linkage to human chromosomal regions 18q, 5q and 13q for bicuspid aortic valve and associated cardiovascular malformations.

The aim of this study was to identify regions of the genome that harbor genes influencing inheritance of bicuspid aortic valve (BAV) and/or associated cardiovascular malformation (CVM). Aortic valve disease is an important clinical problem, which often results in valve replacement, the second most common cardiac surgery in the United States. In every age group, a majority of cases of valve disease involves a BAV. BAV is the most common CVM with a reported prevalence of 1-2%. Heritability studies indicate that BAV determination is almost entirely genetic. We used a family-based genome-wide linkage analysis with microsatellite markers. Parametric and nonparametric analyses were performed with the software GENEHUNTER and SOLAR (Sequential Oligogenic Linkage Analysis Routines). Thirty-eight families (353 subjects) with BAV and/or associated CVM were assessed. Each participant underwent a standardized echocardiographic examination. The highest LOD score, 3.8, occurred on chromosome 18q between markers D18S68 and D18S1161. Two other chromosomal regions, 5q15-21 (between D5S644 and D5S2027) and 13q33-qter (between D13S1265 and 13qter), exhibited suggestive evidence of linkage (LOD > 2.0). Further, two previously reported linkage peaks on 9q34 and 17q24 were replicated in family specific analyses. No significant X chromosome linkage peaks were identified. In this genome-wide scan we demonstrate for the first time, that BAV and/or associated CVM exhibit linkage to chromosomes 18q, 5q and 13q. These regions likely contain genes whose mutation results in BAV and/or associated CVM indicating their important role in valvulogenesis and cardiac development.

Aortic Valve↗