Search PubMed⌕ Search

Biomedical subjects

J F Matthias Bechtel

Publications and source records attributed to J F Matthias Bechtel.

16 recordsLinked to original sources

[Reconstructive surgery of the aortic valve: the Ross, David, and Yacoub procedures].

The aortic valve consists of three cusps attached to the wall of the aortic root. During the cardiac cycle, the aortic root undergoes complex movements that precede and aid opening and closing of the aortic valve. The aortic valve cusps themselves form thin-walled pocket-like structures, made from specialized tissue with fibrous, elastic, nervous, and muscular properties. The complex interactions of this tissue with the aortic root and within the cardiac cycle are only incompletely understood yet. In summary, the aortic valve is a complex structure which shows a perfect function in systole and diastole and under a wide range of hemodynamic conditions. No valve prosthesis (so far) can keep up with the function of the native aortic valve. Therefore, surgical techniques have been invented that aim at sparing the aortic valve or replacing it with very similar autologous tissue. Besides the resulting (near) normal valve function, one appealing advantage of these techniques is that oral anticoagulation can be abandoned completely. If the valve cusps themselves are normal, but the aortic root is aneurysmatic or dissected (with or without resulting secondary aortic insufficiency), the aortic valve can be spared by resecting the aortic root tissue and replacing it by a vascular graft. The aortic valve can then be implanted into the vascular graft in a way described by David, or can be remodeled into it (Yacoub technique) - in this case, the graft first needs to be incised at its base so that the three commissures of the valve can be sewn into the three incisions. This way pseudosinuses within the vascular graft are created. The sinuses within the aortic root are considered important for aortic valve function and coronary perfusion. On the other hand, incisions at the base of the vascular graft harbor the potential for redilatation of the aortic root because of a missing circular fixation. Such a fixation is achieved by the David technique. Therefore, there is a great debate in the surgical community which valve-sparing technique is the best and numerous modifications of the original techniques exist. A clear clinical advantage of one technique over the other could not be demonstrated so far, but many authorities advise that the David technique is to be used preferentially in patients with Marfan's syndrome (or other connective tissue disorders) and those with a very wide basal aortic root. If the aortic valve cusps themselves are diseased and cannot be reconstructed, the autologous pulmonary valve is the most physiological substitute. Replacing the aortic valve with the autologous pulmonary valve is named Ross procedure. The defect in the right ventricular outflow tract that is created while harvesting the autograft must be reconstructed during the same procedure; usually, a pulmonary valve allograft is used for this purpose. With all reconstructive surgical techniques and with all autologous replacements there is a risk of reoperation, mainly (besides technical issues) because it is feared that leaving autologous tissue in place leads to recurrence of the original illness. The published results, however, with aortic valve-sparing surgery and with the Ross procedure show that the risk of reoperation appears to be very acceptable. This statement is especially true for the Ross procedure for which more and longer experience exists worldwide. Echocardiographic studies show that the aortic valve function after valve-sparing techniques and - especially - after the Ross procedure is indeed excellent. Therefore, patients with aortic root pathologies or aortic valve diseases should be informed about valve-sparing aortic root reconstructive techniques or the Ross procedure. The choice of technique should be made in close contact between patient, cardiologist, and cardiac surgeon. However, the described techniques require extensive experience within the surgical team.

Aortic Aneurysm↗

Optimal size of a monocusp patch for reconstruction of a hypoplastic pulmonary root: an experimental study in pigs.

BACKGROUND: Transannular patching is often performed to relieve congenital pulmonary stenosis, especially in tetralogy of Fallot. Theoretically, a monocusp patch can reduce patch-related pulmonary regurgitation, but the optimal size relation between the implant and the native hypoplastic pulmonary root is not well defined. METHODS: In 11 pigs, peak pressure gradient and regurgitation fraction across the pulmonary root were measured. During cardiopulmonary bypass, two cusps including the pulmonary artery wall were resected and the midpoint of the free margin of the remaining cusp was sutured to the sinus wall to imitate a hypoplastic pulmonary root. Transannular patching was performed using a noncoronary segment of a porcine aortic root. After discontinuation of cardiopulmonary bypass, all measurements were repeated. Thereafter, the cusp of the patch was resected, and all measurements again repeated. Anatomic dimensions were determined after the pigs had been sacrificed. RESULTS: Regurgitation fraction increased from 0.2% +/- 3.4% at baseline to 15.5% +/- 6.2% after reconstruction with a monocusp patch and to 60.0 +/- 18.6% after the cusp of the monocusp patch had been resected (p < 0.001). The median peak pressure gradient increased from 0 to 1 to 6 mm Hg (p = 0.013), respectively. The regurgitation fraction negatively correlated with the ratio of the length of the monocusp patch to that of the hypoplastic pulmonary root (r = -0.63, p = 0.037). CONCLUSIONS: A monocusp patch for reconstruction of a hypoplastic pulmonary root results in significantly less regurgitation than a nonvalved patch of the same size, while the peak pressure gradient remains normal. The lowest regurgitation fraction was observed with a monocusp patch two-times the length of the circumference of the hypoplastic pulmonary root.

Animals↗

Mid-term findings on echocardiography and computed tomography after RVOT-reconstruction: comparison of decellularized (SynerGraft) and conventional allografts.

OBJECTIVE: The immune response against human-leucocyte-antigens on donor-cells may be an important factor contributing to the degeneration of allograft-valves. We have previously reported that the use of the decellularized allograft SynerGraft (CryoLife) reduces the immunologic response of the allograft-recipient. In this study we compare the echocardiographic and computed tomography angiographic (CTA) findings of SynerGrafts with conventional cryopreserved allografts. METHODS: 22 patients who received a pulmonary SynerGraft (SG-group) (21 during a Ross-procedure) underwent CTA and resting echocardiography (median: 10 months postoperatively). 47 randomly chosen patients who underwent a Ross-procedure served as controls (C-group) (median: 32 months postoperatively). RESULTS: Neither the pressure gradients (mean: SG=9+/-4 vs C=10+/-4mmHg; P=0.64) across the allograft, nor the effective orifice area (EOAI) (SG=0.93+/-0.80 vs C=0.93+/-0.42cm(2)/m(2); P=0.96) differed between the groups. The EOAI showed a significant correlation with the smallest allograft-conduit-area measured on CTA (r=0.81; P<0.001) which was most frequently (n=34) found in the proximal postvalvular tubular part of the conduit. Calcifications (n=11) or a fibroproliferative reaction (n=15) were rarely observed. Overall, there were no radiologic differences between the groups. On CTA, the smallest diameter of the allograft-conduits was significantly smaller than the diameter given on the cryopreservation protocol (SG=16+/-3 and C=17+/-3mm vs 25mm in both groups; P<0.001 each) whereas the diameter of the distal part of the allograft was not (SG=24+/-2, P=0.066, and C=25+/-3mm, P=0.82). CONCLUSIONS: Despite a significant shorter follow-up in the SynerGraft-group, no functional or radiologic differences were observed as compared to control-patients. The smallest diameter is located almost exclusively at the proximal level of allograft-conduits.

Adult↗

Diseased vein grafts express elevated inflammatory cytokine levels compared with atherosclerotic coronary arteries.

BACKGROUND: The pathologic modifications characterizing vein graft disease resemble those observed in native arteriosclerosis, but in accelerated form. Although both disorders are considered to be inflammatory diseases, it remains to be determined whether diseased vein grafts and atherosclerotic coronary arteries differentially express inflammatory mediators. Therefore, we examined whether differences in the expression of proinflammatory cytokines by these two distinct vascular pathologies favor the accelerated inflammation within diseased vein grafts. METHODS: The messengerRNA expression of various cytokines (interleukin-1 beta [IL-1 beta], IL-6, IL-8, tumor necrosis factor-alpha [TNF-alpha], interferon-gamma [IFN-gamma]) was quantified using real-time reverse transcriptase-polymerase chain reaction (RT-PCR) in tissue samples of native saphenous veins (NSV, n = 5), diseased coronary arteries (CAD, n = 25), and diseased vein grafts (VG, n = 13). RESULTS: Native saphenous veins did not contain any detectable transcripts except for IFN-gamma. As expected, CAD was characterized by the expression of IL-1 beta, IL-6, IL-8, IFN-gamma, and TNF-alpha mRNA. Interestingly VG also expressed these mediators, but at markedly higher levels. Quantification by RT-PCR revealed that, compared with specimens from the CAD group, VG specimens contained 5.8 +/- 1.2 times, 286 +/- 22 times, and 29 +/- 7.3 times as many transcripts for the cytokines IL-1 beta, IL-6 and TNF-alpha, respectively, as well as 25 +/- 8.3 times more transcripts for the chemokine IL-8. In contrast, the expression of IFN-gamma transcripts did not differ among the groups. CONCLUSIONS: The elevated expression of proinflammatory cytokine transcripts supports the hypothesis that diseased vein grafts, compared with atherosclerotic coronary arteries, are characterized by enhanced inflammatory activity that might accelerate atherosclerotic modifications. This may implicate new therapeutic strategies for the prevention of vein graft disease.

Aged↗

High incidence of sudden death late after anterior LV-aneurysm repair.

OBJECTIVES: Sudden death due to ventricular arrhythmias occurs frequently among patients with dilated cardiomyopathy and congestive heart failure (CHF). In patients with left ventricular (LV) aneurysms, LV-aneurysm repair (LVAR) reduces LV-size and ameliorates symptoms of CHF, but the incidence of late sudden death is unknown, especially after LVAR without concomitant anti-arrhythmic therapy. METHODS: Between June 1993 and June 1999, 147 patients (70% males; 62+/-9 years) with CHF (median: NYHA III) due to anterior LV-aneurysms underwent LVAR. None of the patients underwent anti-arrhythmic surgical procedures concomitant to LVAR. Ninety percent of the patients had additional myocardial revascularization. Hospital records and laevocardiograms were reviewed, and follow-up information was obtained. RESULTS: In-hospital mortality was 4.1% (n=6). The median follow-up was 3.7 years (0.1-73.4 months; overall 462 patient-years). At follow-up, the patients had significantly less symptoms than preoperatively (median: NYHA II, P<0.001). Nineteen patients had died (5-year survival rate 78%). Of these late deaths, 84% (n=16) were cardiac-related, among which sudden death was most frequent (n=7). Predictors of sudden death were a bypass graft to the right coronary artery (P=0.0100), ventricular tachyarrhythmias early postoperatively (P=0.0315), and cross-clamp time (P=0.0496). CONCLUSIONS: Although the survival and functional state of most patients were good after LVAR without concomitant anti-arrhythmic surgery, we observed a high incidence of late sudden death, which was-among others-significantly associated with postoperative ventricular tachyarrhythmias. To further improve outcomes, intra- and postoperative anti-arrhythmic therapy is advisable in patients undergoing LVAR.

Aged↗

Significant damage of the conduction system during cardioplegic arrest is due to necrosis not apoptosis.

OBJECTIVES: Ventricular conduction disturbances following cardioplegic arrest remains a serious, yet unsolved problem. In the present study we examined whether myocardial conduction cells (MCC, Purkinje fibers) are more vulnerable to ischemia/reperfusion injury than working myocardial cells and whether the damage is due to necrosis or apoptosis. METHODS: Mini-pigs were subjected to 60 min of crystalloid (St Thomas; n = 15 group I) or blood (Buckberg; n = 6 group II) cardioplegic arrest followed by 3 h of reperfusion. Animals not subjected to either procedures served as controls (n = 5). Ventricular myocardial specimens were investigated by hematoxylin and eosin (HE) and periodic acid Schiff (PAS) staining and immunohistochemical labeling of apoptosis-associated proteins (Bax, Bcl-2, Caspase-3). DNA-breaks were visualized by in situ end labeling (terminal deoxynucleotidyl transferase dUTP-biotin nick-end labeling, TUNEL). Electron microscopy confirmed apoptosis or necrosis. RESULTS: MCC of control hearts intrinsically expressed Bax, Bcl-2, and Caspase-3 without signs of either apoptotic or necrotic damage. Subendocardial Purkinje fibers of groups I and II hearts exhibited focal damage, with reduced labeling of apoptosis-associated proteins, glycogen loss, karyopycnosis and increased eosinophilia (15/21 hearts). The majority of damaged MCC displayed nuclear TUNEL-positivity (2.8+/-2.5% of MCC), whereas the average TUNEL-rate of the adjacent working myocardium was low (<0.1%). Electron microscopy demonstrated ischemic changes in MCC consistent with cellular necrosis. CONCLUSIONS: Ischemia/reperfusion injury due to cardioplegic arrest inflicts significant damage on subendocardial MCC, but not on working myocardium. Ultrastructural and light-microscopic findings are consistent with coagulation necrosis, rather than apoptosis.

Animals↗

Hemodynamic performance following the Ross operation: comparison of two different techniques.

BACKGROUND AND AIM OF THE STUDY: The Ross operation as aortic valve replacement has undergone technical evolution. Originally described as a subcoronary implant, the full-root replacement technique is now more common worldwide. It remains unclear which of the two techniques has the better results. Hence, the hemodynamic performances of the two implantation methods, as applied by two experienced centers, were compared as part of the German Ross Registry. METHODS: In total, 132 (Group 1, root replacement, mean age 40 +/- 14 years) and 249 (Group 2, subcoronary implant, mean age 48 +/- 14 years) consecutively operated patients were compared clinically and echocardiographically. Data were analyzed focusing on pulmonary autograft and homograft function at mid-term (2.78 +/- 1.89 versus 2.26 +/- 2.11 years). RESULTS: Echocardiography revealed autograft peak systolic gradients of 5.0 +/- 2.7 mmHg for Group 1 and 6.7 +/- 3.7 mmHg for Group 2 (p < 0.05), and an indexed effective orifice area (EOA) of 1.98 +/- 0.57 cm2/m2 and 1.64 +/- 0.43 cm2/m2 (p < 0.05), respectively. Homograft peak systolic gradients were 15.6 +/- 9.0 mmHg and 11.7 +/- 6.8 mmHg for Groups 1 and 2 (p < 0.05) respectively, and the indexed EOA with regard to the homograft was 1.08 +/- 0.49 cm2/m2 and 1.26 +/- 0.50 cm2/m2 (p < 0.05). Autograft insufficiency grade > I was present in 1.5% (2/132) of Group 1 and 2.8% (7/249) of Group 2 patients. Pulmonary insufficiency grade > I was 17.4% (23/132) for Group 1 and 4.8% (12/249) for Group 2 (p < 0.05). CONCLUSION: Although both groups enjoyed excellent hemodynamics in the mid-term, the root replacement technique had the advantage of larger annulus diameters and greater aortic EOA. Clinically relevant autograft regurgitation in both groups was gratifyingly rare, and seemed to be independent of surgical technique. Long-term durability of the more demanding subcoronary technique versus the problems of larger dimensions of the sinus of Valsalva and sinotubular junction in the free-root technique, remains to be proven. Apparent differences in pulmonary homograft hemodynamics can most likely be explained by surgical differences, younger patients in Group 1, and by homograft variation.

Adult↗

Local generation of C-reactive protein in diseased coronary artery venous bypass grafts and normal vascular tissue.

BACKGROUND: Venous coronary artery bypass grafts (CABGs) are prone to accelerated atherosclerosis. In atherosclerotic diseases, serum C-reactive protein (CRP) levels have become an important diagnostic and prognostic marker. The origin of CRP in this setting remains to be elucidated. METHODS AND RESULTS: Monoclonal anti-CRP identified CRP expression in medial and intimal alpha-actin-positive smooth muscle cells (SMCs) of diseased CABGs with type V and VI lesions and also of native saphenous veins of atherosclerotic individuals. In addition, patent coronary arteries with type IV and V but not with type I through III lesions exhibited intense SMC staining for CRP. Calcified desobliterates of occluded coronary arteries with end-stage disease did not show SMC staining for CRP and were consistently negative for CRP mRNA, as detected by means of real-time polymerase chain reaction. However, CRP mRNA was expressed in 11 of 15 diseased CABGs and also in 10 of 15 native veins. By contrast, only 3 of 18 internal mammary and 4 of 12 radial arteries with virtually no atherosclerosis were positive for CRP mRNA. CONCLUSIONS: CRP is produced by SMCs of atherosclerotic lesions with active disease but not in end-stage plaques. The role of CRP constitutively expressed by normal vascular tissue in vein graft disease has yet to be elucidated.

Arteriosclerosis↗

Low-energy cardioversion versus medical treatment for the termination of atrial fibrillation after CABG.

BACKGROUND: Atrial fibrillation (AF) is the most frequent complication after cardiac surgery and can cause considerable morbidity. Low-energy cardioversion (LEC) using biatrial epicardial wires implanted during surgery has been shown to be effective and safe in conscious patients, but has not been directly compared with medical treatment so far. We therefore prospectively studied the efficacy of LEC in men 60 years of age and older. METHODS: Sixteen patients (mean +/- SD, 66.4 +/- 5.4 years) were randomized to LEC and 32 patients (66.3 +/- 5.0 years) to standarized medical treatment in the event of postoperative AF. Age, comorbidity, and surgical variables did not differ significantly between the groups. RESULTS: After cardiac surgery, AF occurred in 6 patients (38%) assigned to LEC and in 11 patients assigned to medical treatment (34%; p = NS). Low-energy cardioversion restored sinus rhythm in all but 1 patient, and 1 patient in the LEC group had early recurrence of AF. All other patients in the LEC group had prompt and stable restoration of sinus rhythm. Medical treatment was associated with the restoration of sinus rhythm in all patients. Although the total time in AF was decreased significantly by LEC (median 5 minutes versus 22 hours; p = 0.037), the length of postoperative hospitalization was not (5.1 +/- 1.4 days for the LEC group compared with 5.3 +/- 1.6 days for controls). CONCLUSIONS: Low-energy cardioversion significantly decreased the amount of time cardiac surgery patients spent in AF after the operation. Larger studies are needed to determine whether this new treatment modality has the ability to decrease morbidity associated with postoperative AF and is cost-effective.

Aged↗

Up to 7 years' experience with valve-sparing aortic root remodeling/reimplantation for acute type A dissection.

BACKGROUND: Aortic valve-sparing operations for acute type A dissection are appealing and innovative but less well defined surgical techniques requiring further evaluation. METHODS: We reviewed all consecutive patients with acute type A dissection who underwent either the remodeling (group 1, n = 21) or the reimplantation valve-sparing technique (group 2, n = 15) since October 1994. Patients were followed up clinically and echocardiographically for as long as 41.3 months (group 1) and 87 months (group 2). RESULTS: Hospital mortality was 19% (n = 4) for group 1 and 20% (n = 3) for group 2. Permanent new neurologic symptomatology occurred in 1 patient (3.6%). Three patients in group 1 required reoperation owing to redissection. No patient had an aortic insufficiency of more than grade 1. No late neurologic or thrombembolic events occurred. There was no statistically significant difference between both groups with respect to clinical and hemodynamic data. CONCLUSIONS: Remodeling and reimplantation aortic valve-preserving operations in acute type A dissection can be performed with adequate perioperative risk and excellent midterm aortic valve function. We found no evidence of one technique being superior to the other, however durability of the remodeling technique needs critical consideration especially in Marfan syndrome and when glue is used.

Acute Disease↗

A rise of MMP-2 and MMP-9 in bronchoalveolar lavage fluid is associated with acute lung injury after cardiopulmonary bypass in a swine model.

Postoperative acute lung injury (ALI) contributes to the morbidity and mortality following cardiopulmonary bypass (CPB). To determine whether the presence of matrix metalloproteinases (MMPs) is associated with ALI after CPB, MMP-2 and MMP-9 activities in bronchoalveolar lavage fluid (BALF) were compared with parameters indicating impaired gas exchange. In a prospective study, 17 minipigs were subjected to CPB for 60 min. Before and at five and 180 min after CPB, MMP-2 and MMP-9 were assayed in BALF and the arterial-alveolar gradient of oxygen tension (AaDO2), the pulmonary capillary wedge pressure (PCWP) and the water content of lung tissue samples (Wt) were evaluated and compared with baseline values. MMP-2 and MMP-9 increased significantly 5 minutes (2.1- and 6.2-fold, respectively) and 180 minutes (3.4- and 14.3-fold, respectively) post-CPB. AaDO2 and Wt, but not PCWP, increased significantly 180 minutes after CPB and only AaDO2, but not PCWP or Wt, was significantly correlated with MMP-2 (r = 0.66, p = 0.006) and MMP-9 (r = 0.62, p = 0.01). In conclusion, high levels of MMP-2 and MMP-9 in the pulmonary compartment are associated with ALI after CPB.

Animals↗

Histopathological grading of ascending aortic aneurysm: comparison of patients with bicuspid versus tricuspid aortic valve.

BACKGROUND AND AIMS OF THE STUDY: Bicuspid aortic valve (BAV) is a common inherited condition that is often accompanied by ascending aortic aneurysm. A high level of histological wall abnormalities was reported to be present in non-dilated aortas of patients with BAV. In patients with tricuspid aortic valve, there appears to exist a direct relationship between the diameter of the ascending aorta and degree of histopathological aortic wall abnormalities. Whether this situation exists in patients with BAV has not yet been investigated. METHODS: Surgical and medical records of all patients undergoing surgery of the ascending aorta were reviewed. A total of 65 patients was identified in whom an aortic wall specimen was obtained intraoperatively. These specimens were systematically re-evaluated, and graded according to the severity of seven histopathological conditions: fibrosis, atherosclerosis, medionecrosis, cystic medial necrosis, smooth muscle cell orientation, elastic fiber fragmentation, and inflammation. RESULTS: BAVs were present in 26 patients (40%). Patients with BAV had significantly less aortic wall alterations than patients with tricuspid aortic valves (p < 0.001) in all variables examined. The severity of aortic wall abnormalities was significantly dependent on aortic diameter in patients with BAV as well as tricuspid aortic valve (p = 0.036 and 0.019), but dependent on age (p = 0.009) only in patients with tricuspid aortic valve. CONCLUSION: The study results provide evidence that ascending aortic aneurysm in patients with BAV differs clinically and histologically from that in patients with tricuspid aortic valve. Further studies are needed to elucidate the impact of inherited and acquired aortic wall abnormalities on the development of aneurysms.

Adult↗

Evaluation of the decellularized pulmonary valve homograft (SynerGraft).

BACKGROUND AND AIM OF THE STUDY: Rejection is thought to contribute to the degeneration of valved homografts. A novel cryopreserved decellularized homograft valve (SynerGraft; CryoLife, Inc.) offers the unique opportunity to gain new insight into the immunology of homograft implantation and its significance for valve function. METHODS: Twenty-four patients (group I; mean age 37 +/- 11 years) underwent implantation of a pulmonary SynerGraft and were examined at one and six months postoperatively; 22 patients (group II; mean age 41 +/- 17 years) with conventional homografts served as controls. Temperature, C-reactive protein (CRP) levels and white blood cell count (WBC) were studied perioperatively. Follow up included echocardiography and anti-human leukocyte antigen (HLA) class I antibody determination. RESULTS: Significantly lower temperatures were measured in group I (p = 0.019). CRP level and WBC each increased postoperatively, but did not differ between groups. During follow up, none of the SynerGraft patients became positive for anti-HLA antibodies, compared with 66% of controls (p = 0.011). Homograft diameter and valve orifice area were decreased significantly at one month after surgery in groups I and II (25 +/- 1 versus 18 +/- 3 mm; 25 +/- 1 versus 19 +/- 2 mm, respectively; p <0.001 both groups). Transvalvular pressure gradients significantly increased during follow up. CONCLUSION: Implantation of the SynerGraft pulmonary homograft appeared safe, and though evidence was found of a reduced immunologic response after SynerGraft implantation this (unexpectedly) did not translate into any hemodynamic advantage. Hence, factors other than rejection appear as the main contributions to the observed functional changes.

Adult↗

Is the kaolin or celite activated clotting time affected by tranexamic acid?

BACKGROUND: During cardiopulmonary bypass, the activated clotting time is frequently used for determination of anticoagulation, and either Celite or kaolin are used as activators. If aprotinin is administered concomitantly, the Celite activated clotting time (C-ACT) becomes significantly higher than the kaolin activated clotting time (K-ACT). Therefore, insufficient anticoagulation using C-ACT in the presence of aprotinin is a major concern. Whether the application of tranexamic acid (TA), a pharmacologic alternative to aprotinin, has similar effects has not been studied before. METHODS: An in vitro study using the blood of healthy volunteers was performed. Both C-ACT and K-ACT were measured at baseline, after adding TA, and after adding TA and heparin. In addition, 30 patients undergoing primary cardiac operations had simultaneous measurements of C-ACT and K-ACT after skin-incision, 5 minutes after the application of heparin and TA, every 30 minutes during cardiopulmonary bypass, and 10 minutes after the application of protamine. RESULTS: In vitro, C-ACT and K-ACT correlated significantly at each measurement. Tranexamic acid had no influence on the activated clotting time. In vivo, C-ACT and K-ACT did not differ significantly, but at each time C-ACT tended to be greater than K-ACT (p = 0.086). The average difference between K-ACT and C-ACT was stable before and after the application of TA (p = 0.85) but the variability of the differences significantly increased during cardiopulmonary bypass (p < 0.001). CONCLUSIONS: Application of TA does not seem to differentially affect the mean C-ACT and K-ACT. No recommendation seems warranted to prefer one activator over the other in patients receiving TA.

Aged↗

Lung protection during total cardiopulmonary bypass by isolated lung perfusion: preliminary results of a novel perfusion strategy.

BACKGROUND: The present pilot study was conducted to evaluate the effect of isolated short-term lung perfusion during cardiopulmonary bypass (CPB) on inflammatory response and oxygenation. METHODS: A total of 24 patients undergoing elective cardiac surgery with routine CPB were prospectively assigned to three groups. Group I (n = 7), control subjects receiving neither lung perfusion nor ultrafiltration; group II (n = 9), patients undergoing lung perfusion; and group III (n = 8), patients undergoing lung perfusion plus ultrafiltration. Lung perfusion consisted of single-shot hypothermic pulmonary artery perfusion with oxygenated blood. Proteins indicative of leukocyte activation and lung injury were measured in plasma and bronchoalveolar lavage fluid (BALF). The alveolar-arterial oxygen gradient (A-aDO2) and the oxygenation index (PO2/FiO2) were also determined. RESULTS: Oxygenation values were best preserved in group III, followed by group II. After CPB, elastase-alpha1-proteinase inhibitor complex had increased in plasma in all groups; in BALF it increased in groups I and II, but not in group III. Alpha2-macroglobulin increased significantly in BALF in group I but not in groups II and III. CONCLUSIONS: These preliminary results provide some evidence that single-shot hypothermic lung perfusion with oxygenated blood at the beginning of CPB may have a protective effect on the lungs, especially when combined with ultrafiltration.

Adult↗

Discrepancies between sizer and valve dimensions: implications for small aortic root.

BACKGROUND: Precise labeling of sizer and valve diameters is crucial for optimal valve selection especially in the small aortic root. This study examines the accuracy of manufacturers' markings on small aortic prostheses and sizers. METHODS: Sizer and valve dimensions of 22 different mechanical aortic prostheses (19 to 23 mm) were evaluated by caliper micrometer measurements. RESULTS: Nearly all sizers exceeded their marked dimensions by up to 1.0 mm. Measured tissue annulus diameters for 19-mm-labeled valves varied between 18.3 and 19.6 mm, for 21-mm valves from 20.5 to 21.6 mm, and for 23-mm valves from 22.4 to 23.5 mm, respectively. The orifice areas ranged from 1.5 to 2.06 cm2 for 19-mm valves, from 2.0 to 2.55 cm2 for 21-mm valves, and from 2.4 to 3.09 cm2 for 23-mm valves, respectively. CONCLUSIONS: Actual sizer dimensions and tissue annulus diameters of various small mechanical aortic prostheses varied considerably from their marked diameters. These differences should be considered to ensure the optimal prosthesis selection for each patient.

Aortic Valve↗