Search PubMed⌕ Search

PubMed · 9646921

High temperature and temperature programming in capillary HPLC.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N M Djordjevic, F Houdiere, P Fowler. High temperature and temperature programming in capillary HPLC.. https://doi.org/10.1002/(sici)1099-0801(199805%2F06)12%3A3%3C153%3A%3Aaid-bmc792%3E3.0.co%3B2-%23

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Kinetics of oxidation of chlorobenzenes and phenyl-ureas by Fe(II)/H2O2 and Fe(III)/H2O2. Evidence of reduction and oxidation reactions of intermediates by Fe(II) or Fe(III).

The rates of degradation of 1,2,4-trichlorobenzene (TCB), 2,5-dichloronitrobenzene (DCNB), diuron and isoproturon by Fe(II)/H2O2 and Fe(III)/H2O2 have been investigated in dilute aqueous solution ([Organic compound]0 approximately 1 microM, at 25.0 +/- 0.2 degrees C and pH < or = 3). Using the relative rate method with atrazine as the reference compound, and the Fe(II)/H2O2 (with an excess of Fe(II)) and Fe(III)/H2O2 systems as sources of OH radicals, the rate constants for the reaction of OH* with TCB and DCNB were determined as (6.0 +/- 0.3)10(9) and (1.1 +/- 0.2)10(9) M(-1) s(-1). Relative rates of degradation of diuron and isoproturon by Fe(II)/H2O2 were about two times smaller in the absence of dissolved oxygen than in the presence of oxygen. These data indicate that radical intermediates are reduced back to the parent compound by Fe(II) in the absence of oxygen. Oxidation experiments with Fe(III)/H2O2 showed that the rate of decomposition of atrazine markedly increased in the presence of TCB and this increase has been attributed to a regeneration of Fe(II) by oxidation reactions of intermediates (radical species and dihydroxybenzenes) by Fe(III).

Chlorobenzenes↗

Trace analysis of ten chlorinated benzenes in water by headspace solid-phase microextraction.

Headspace solid-phase microextraction (SPME), as a simple, solvent-free method, has been applied to the analysis of 10 chlorinated benzenes (CBs) present at trace levels in water samples. An SPME fibre coated with 100-microm thick poly(dimethylsiloxane) was used for extraction. The analytical data exhibited a relative standard deviation (RSD) range of 1.19% (for pentachlorobenzene) to 8.19% (for hexachlorobenzene) for the 10 CBs; the RSD of most compounds was under 6%. The sensitivity of the method was enhanced with agitation and with addition of salt to the sample solutions. With mass spectrometric detection, the limit of detection was below 0.006 microg/l for all 10 CBs after a 30-min sampling time. The linearity range was 0.02-20 microg/l for the compounds studied. Water samples collected from a reservoir, and from the tap in a laboratory were analysed using the optimised conditions.

Chlorobenzenes↗

Analysis of volatile organic compounds, using the purge and trap injector coupled to a gas chromatograph/ion-trap mass spectrometer: review of the results in Dutch surface water of the Rhine, Meuse, Northern Delta Area and Westerscheldt, over the period 1992-1997.

Volatile organic compounds are widely introduced into the Dutch aquatic environment. Liquid-liquid extraction and isolation by means of resins give poor recoveries for volatiles. In this study, a method has been developed to analyse these compounds with a purge and trap injection (PTI) coupled to a chromatograph/ion trap mass spectrometer. Volatile compounds are "purged" from the sample by carrier gas flow and transported through a condenser to a cooled trap. The bulk of liquid matrix is condensed in the condenser, while volatile compounds are left unaffected. The compounds of interest are trapped at a low temperature, by liquid nitrogen in the cooled trap of fused silica. Injection takes place by flash heating of the trap. The detection limits of the volatile compounds are in the range of 0.001-0.04 microgram l-1, in full spectrum mode. In this paper a review of the results in Dutch surface water of the Rhine, Meuse, Northern Delta Area and Westerscheldt, over the period 1992-1997, is presented. For calamities causing high levels of volatiles, the method is very useful. The compounds can be monitored over a certain period. In the Meuse, high levels of volatile organic compounds are observed. Diisopropyl ether at a maximum of 592 micrograms l-1.

Chlorobenzenes↗