Publications and source records attributed to N M Djordjevic.

8 recordsLinked to original sources

Evaluation of ODS-AQ stationary phase for use in capillary electrochromatography.

The aim of this study was to evaluate the applicability of ODS-AQ packing material as a stationary phase in capillary electrochromatography (CEC). The electroosmotic flow created on an ODS-AQ stationary phase was measured at different mobile phase compositions and at different column temperatures. It was observed that the electroosmotic flow generated in the column increased by 50% when the temperature of the system was raised from 20 degrees C to 60 degrees C, while all other conditions were kept constant. The electroosmotic flow produced by the ODS-AQ stationary phase was found to be comparable to the flow generated in a column packed with Nucleosil bare-silica material. In addition, a set of polar compounds (D-lysergic acid diethylamide derivatives) was utilized to determine the influence of temperature and mobile phase composition on their chromatographic behavior on an ODS-AQ stationary phase in a CEC mode. A linear relationship between the solute retention factor and column temperatures was seen over the temperature range studied (20 degrees C to 60 degrees C). A quadratic function was used to describe the changes in the solute retention factors with variation of acetonitrile concentration in the mobile phase.

Chromatography, High Pressure Liquid↗

Separation of peptides utilizing ultrahigh-temperature micellar electrokinetic chromatography.

The use of ultrahigh column temperatures, up to 110 degrees C, in micellar electrokinetic capillary chromatography was investigated. The number of plates generated per unit time increased from 0.22 to 12.8 plates/s for separations at 15 degrees C and 110 degrees C, respectively. Ultrahigh-temperature micellar electrokinetic capillary chromatography was used for the separation of cyclic undecapeptides (cyclosporins). A minimum resolution of 1.39 was calculated for a critical peak pair at 110 degrees C, which is more than a 50% increase over resolution generated at 40 degrees C. During a run time of more than 90 min at 110 degrees C and at pH 9.3, no sample degradation or solvent boiling was observed.

Acetonitriles↗

High temperature and temperature programming in capillary electrochromatography.

In electrochromatography, solvent electrophoretic mobility and solute partitioning are temperature dependent processes. If temperature variations are controlled, solute selectivity and analysis times can be tailored. In this study the feasibility of temperature programming in capillary electrochromatography (CEC) was demonstrated using a reversed-phase CEC mode. The outcome of programmed separations was compared with isothermal, isocratic and isorheic (constant flow) separations. The combined effects of column temperature and mobile phase flow-rate changes during the separation run, resulted in up to a 50% reduction in the separation run time, without adversely affecting the quality of separation. For capillary electrochromatography, temperature programming may be a valuable alternative to solvent programming modes because of the great technical difficulties associated with carrying out solvent gradient elution.

Electrophoresis, Capillary↗

Reversed-phase liquid chromatographic separation of complex samples by optimizing temperature and gradient time I. Peak capacity limitations.

The separation of samples that contain more than 15 to 20 analytes (n > 15-20) is typically difficult and usually requires gradient elution. We have examined the reversed-phase liquid chromatographic separation of 24 samples with 8 < or = n < or = 48 as a function of temperature T and gradient time tG. The required peak capacity was determined for each sample, after selecting T and tG for optimum selectivity and maximum sample resolution. Comparison of these results with estimates of the maximum possible peak capacity in reversed-phase gradient elution was used to quantify the maximum value of n for some required sample resolution (when T and tG have been optimized). These results were also compared with literature studies of similar isocratic separations as a function of ternary-solvent mobile phase composition, where the proportions of methanol (MeOH), tetrahydrofuran (THF) and water were varied simultaneously. This in turn provides information on the relative effectiveness of these two different method development procedures (optimization of T and tG vs. % MeOH and % THF) for changing selectivity and achieving maximum resolution.

Chromatography, Liquid↗

Reversed-phase liquid chromatographic separation of complex samples by optimizing temperature and gradient time II. Two-run assay procedures.

By optimizing column temperature T and gradient time tG, complex samples can often be separated by means of reversed-phase high-performance liquid chromatography (RP-LC). Conclusions reached in Part I suggest that the complete separation of such samples will be difficult, however, when more than 15-20 components are present in the sample. An alternative approach is to carry out two separations with different conditions (T, tG) in each run. The combination of results from these two runs then allows the total analysis of the sample, providing that every sample component is adequately resolved in one run or the other. Examples of this approach, carried out by means of computer simulation, are shown here for several samples of varying complexity. Also considered is the ability of a single separation where T and tG are optimized to enable the separation and analysis of one or more individual sample components from complex mixtures (e.g., drugs in animal plasma), including the resolution of isomeric compounds from each other.

Chromatography, Liquid↗

Simultaneous variation of temperature and gradient steepness for reversed-phase high-performance liquid chromatography method development. I. Application to 14 different samples using computer simulation.

The optimized reversed-phase HPLC separation of 14 different samples is reported, based on simultaneous changes in temperature and gradient steepness. Four experimental runs are required for each sample, following which preferred conditions can be predicted using computer simulation software (DryLab). The overall accuracy and effectiveness of this method development approach is discussed, with particular attention to the use of resolution maps provided by the software. These maps are useful for maximizing resolution for the total sample, for optimizing the separation of a smaller number of selected sample compounds, and as an initial step in the separation of more demanding samples.

Adrenal Cortex Hormones↗

Combined use of temperature and solvent strength in reversed-phase gradient elution. I. Predicting separation as a function of temperature and gradient conditions.

It has been shown previously that computer simulation based on two initial experiments can predict separation in reversed-phase gradient elution as a function of gradient conditions (gradient steepness, gradient range and gradient shape) and column conditions (column length, flow-rate and particle size). The present study extends this capability for changes in temperature. Four initial experiments (two different gradient times, two different temperatures) provide input data that allow predictions of separation as a function of temperature as well as gradient and column conditions. A semi-empirical relationship, tR = a + bT, is able to relate gradient retention time tR to column temperature T (other conditions constant). The accuracy of this approach has been evaluated for 102 solutes and a variety of experimental conditions, including the use of five different HPLC instruments (four different models).

Chromatography, High Pressure Liquid↗