Search PubMed⌕ Search

PubMed · 9535523

A programmable sound processor for advanced hearing aid research.

Abstract

A portable sound processor has been developed to facilitate research on advanced hearing aids. Because it is based on a digital signal processing integrated circuit (Motorola DSP56001), it can readily be programmed to execute novel algorithms. Furthermore, the parameters of these algorithms can be adjusted quickly and easily to suit the specific hearing characteristics of users. In the processor, microphone signals are digitized to a precision of 12 bits at a sampling rate of approximately 12 kHz for input to the DSP device. Subsequently, processed samples are delivered to the earphone by a novel, fully-digital class-D driver. This driver provides the advantages of a conventional class-D amplifier (high maximum output, low power consumption, low distortion) without some of the disadvantages (such as the need for precise analog circuitry). In addition, a cochlear implant driver is provided so that the processor is suitable for hearing-impaired people who use an implant and an acoustic hearing aid together. To reduce the computational demands on the DSP device, and therefore the power consumption, a running spectral analysis of incoming signals is provided by a custom-designed switched-capacitor integrated circuit incorporating 20 bandpass filters. The complete processor is pocket-sized and powered by batteries. An example is described of its use in providing frequency-shaped amplification for aid users with severe hearing impairment. Speech perception tests confirmed that the processor performed significantly better than the subjects' own hearing aids, probably because the digital filter provided a frequency response generally closer to the optimum for each user than the simpler analog aids.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H McDermott. 1998. A programmable sound processor for advanced hearing aid research.. https://doi.org/10.1109/86.662620

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal design of non-Newtonian, micro-scale viscous pumps for biomedical devices.

The present paper addresses the numerical optimization of geometrical parameters of non-Newtonian micro-scale viscous pumps for biomedical devices. The objective is to maximize the mass flow rate per unit of shaft power consumed by the rotor when an external pressure load is applied along the channel that houses the rotor. Two geometric parameters are considered in the optimization process: (i) the height of the channel that houses the rotor (H) and (ii), the eccentricity (epsilon) of the rotor. Three different micro-scale viscous pump configurations were tested: a straight-housed pump (I-shaped housing) and two curved housed pumps (L- and U-shaped housings). The stress-strain constitutive law is modeled by a power-law relation. The results show that the geometric optimization of micro-scale viscous pumps is critical since the mass flow rate propelled by the rotor is highly dependent on epsilon and H. Numerical simulations indicate that mass flow rate is maximized when epsilon approximately 0, namely when the rotor is placed at a distance of 0.05 radii from the lower wall. The results also show that micro-scale viscous pumps with curved housing provide higher mass flow rate per unit of shaft power consumed when compared with straight-housed pumps. The results are presented in terms optimized dimensions of all three configurations (i.e., H(opt) and epsilon(opt)) and for values of the power-law index varying between 0.5 (shear thinning fluids) and 1.5 (shear-thickening fluids).

Biomedical Engineering↗