Search PubMed⌕ Search

PubMed · 9534712

X-ray tubes--continuous innovative technology.

Abstract

The X-ray tube is one of the most important components in any X-ray system. In the beginning, physicists and physicians used gas ion tubes. The so-called Coolidge tube applied a high vacuum and is still used today. Medical examinations have required continuously improved designs of X-ray tubes (smaller focal spots at a higher output). The principle of the Goetze line focus is still applied in any diagnostic X-ray tube. Different anode materials and the rotating anode contributed to an increased output and reduced exposure time. Bearings needed special attention. Spiral groove bearings are the most advanced design today. The heat storage capacity of the anode and the tube housing assembly influences examination time and patient throughput. Cardiac imaging required less motion blurring in cine film images and increasing radiation exposure in interventional procedures called for measures to reduce dose. Protection against radiation and electric shock has always been a concern of design engineers. Focal spot sizes dedicated to specific applications and heat management within the total tube housing assembly will be future issues. Even with the event of ultrasound and MR technology, X-ray procedures will still be applied for diagnostic and interventional purposes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E Ammann, W Kutschera. 1997. X-ray tubes--continuous innovative technology.. https://doi.org/10.1259/bjr.1997.0002

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Repeat right transradial percutaneous coronary intervention in a patient with dextrocardia: the right approach to the right-sided heart.

Dextrocardia (DC) is a rare cardiac condition in which the cardiac location, as well as apex, is rightwardly displaced. As the incidence of atherosclerotic disease is similar to that of the general population, there have been few reports of percutaneous coronary interventions (PCIs) in these patients. Proposed technical strategies for successful angiography and PCI in DC include counter-directional torquing of the catheter, as well as right-left mirror-image inversion angiographic views. All previous reports of DC PCIs have been via transfemoral access.We present a case of successful repeat transradial PCI in a patient with DC. This is first report of transradial coronary angiography, PCI, or repeat PCI in a DC patient. A literature review of technical considerations, including our own recommendations for guide catheter selection, are discussed. We also review the anatomic variations and epidemiology of DC. Although access complications for transradial PCI is known to be lower than that of the transfemoral approach, challenges in technique and concern of repeat access have limited the popularity of the former. Our report demonstrates the safety and feasibility of transradial angiography, PCI, and even repeat PCI, in the rare patient with DC.

Coronary Angiography↗