Search PubMed⌕ Search

PubMed · 9470633

Occlusion maintainer.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G Trigylidas. 1997. Occlusion maintainer.. https://pubmed.ncbi.nlm.nih.gov/9470633/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Marginal adaptation of partial crowns cast in pure titanium and in a gold alloy - an in vivo study.

The aim of the present study was to assess in vivo the marginal integrity of partial crowns cast in pure titanium and in a gold alloy. For this purpose, two groups of 25 molars were prepared for partial crowns and then restored with partial crowns cast in Degulor M gold alloy and in pure titanium. At a subsequent session, replicas were produced using a special impression-taking technique. The scanning electron microscope (SEM) technique was used to perform quantitative margin analysis (Tiffmess 1.8 program). The gold alloy partial crowns displayed significantly (P < 0.05) more continuous margin (marginal quality A, <50 microm), and the titanium partial crowns significantly more marginal quality B (50-100 microm) and C (>100 microm). The results show that better marginal integrity can be achieved with gold alloy than with titanium partial crowns. However, in practical terms the difference in marginal quality is only slight, so that the use of pure titanium for single-tooth restorations is justified.

Cementation↗

Effect of length and diameter of tapered posts on the retention.

The force transmission of tapered unthreaded posts along the root has been reported to be homogenous but their retentive strength was found to be lower compared with those of parallel unthreaded or other kinds of threaded posts. The purpose of this in vitro study was to investigate the effect of length and diameter on the retentive strength of sandblasted tapered prefabricated titanium posts (Erlangen post system). Posts with constant taper angle but with three different lengths (9, 12, 15 mm) and apical diameters (0.5, 0.9, 1.1 mm) were cemented using zinc phosphate cement into the prepared and roughened post spaces of 90 intact anterior teeth. The post retention concerning length and diameter, being independent from each other, was measured by a tensile force test. The retentive strength was found to be proportional to the length as well as to the diameter of the posts. The mean minimum strength (181 +/- 14 N) recorded for the thinnest and shortest post was significantly lower than that of mean maximum strength (612 +/- 85 N) obtained from those of the thickest and longest post. Proportional bond strengths of the posts comprising their surface areas ranged between 6.8 and 7.9 N mm(-2) which were not significantly different between any group. The retention was effected strongly with the increase in the length (approximately 100%) than with the increase in the diameter (approximately 60%). Concerning the posts tested in this study, it is concluded that some caution should be exercised in the choice of post with appropriate length rather than diameter for the tooth concerned.

Cementation↗