Search PubMed⌕ Search

PubMed · 9206707

[New developments in parameter-oriented roentgen densitometry perfusion analysis within the scope of heart catheter studies].

Abstract

X-ray densitometric evaluation of digital subtraction coronary arteriograms allows a qualitative and quantitative detection of contrast medium propagation through the epicardial coronary arteries, the capillary system and the coronary venous system. So-called "time-density-curves" (TDCs) can be generated following Lambert-Beer's law similar to indicator dilution curves by using contrast medium as the indicator. Several time and density parameters can be derived from these TDCs, which are related to local myocardial perfusion. Different animal validation studies have shown the applicability of this concept for in-vivo evaluation of coronary blood flow and myocardial perfusion. Nevertheless, absolute measurement of volumetric coronary blood flow or myocardial perfusion failed. Therefore, relative changes in coronary blood flow or myocardial perfusion in response to pharmacologically induced maximum hyperemia were measured and coronary or myocardial perfusion reserve was calculated as the ratio of hyperemic flow or perfusion divided by baseline values. Despite theoretical attractions for an application during routine cardiac catheterization, this densitometric approach did not get a wide acceptance. Primary reason for this limited use in specialized centers was the time consuming process of densitometric evaluation of the subtraction coronary arteriograms, which require digital cine angiography and necessitates enormous computer hard ware. This main limitation has been overcome since more powerful computer hard ware (processor speed, hard disk space, digitization boards) has become rapidly available during the last years at more moderate pricing and digital techniques today are state of the art in cardiac catheterization laboratories. In addition, soft ware program packages allowed an automatization of the digitization and densitometric evaluation process. These programs include ECG triggered cine image digitization with improved temporal resolution, semiautomatic definition of regions-of-interest including definition of reference regions-of-interest for the detection of background density changes and quality-controlled densitometric parameter analysis. This progress made an application during routine cardiac catheterization feasible. In animal validation studies this improved X-ray densitometric approach for evaluation of local myocardial perfusion was validated versus colour-coded microsphere techniques. The time parameter "rise time", defined as the time from the start of local contrast medium induced density change to its maximum revealed a close correlation (r2 = 0.965) to the results of the microsphere technique over a wide range of perfusion. We have applied this technique before and after coronary interventions such as balloon angioplasty and stenting. Results documented an improvement of poststenotic myocardial perfusion reserve immediately after coronary balloon angioplasty and an additional improvement after adjunct coronary stenting. Only after stenting but usually not after coronary balloon angioplasty alone poststenotic myocardial perfusion reserve gained the intraindividual reference level, measured in a perfusion bed supplied by an epicardial coronary artery without stenoses. These results documented the functional benefit of coronary stenting on poststenotic myocardial perfusion in addition to the well known morphologic benefit with the creation of a larger and more circular conduit.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Haude, G Caspari, D Baumgart, P Spiller, G Heusch, R Erbel. 1997. [New developments in parameter-oriented roentgen densitometry perfusion analysis within the scope of heart catheter studies].. https://doi.org/10.1007/bf03044306

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗