Search PubMed⌕ Search

Biomedical subjects

M Haude

Publications and source records attributed to M Haude.

At least 19 recordsLinked to original sources

Genetic variation of the platelet- surface integrin GPIIb-IIIa (PIA1/A2-SNP) shows a high association with Type 2 diabetes mellitus.

AIMS/HYPOTHESIS: The gene encoding the beta(3)-subunit (GPIIIa) of the platelet alpha(2)beta(3)-integrin (fibrinogen receptor) shows a polymorphism PlA1/A2 with the A2 allele putatively associated with an increased risk of acute ischaemic events. This study investigated whether Type 2 diabetes as a particular macrovascular risk factor associates with the thrombogenic PIA2 genotype. METHODS: The PlA genotype was determined in 112 consecutive Type 2 diabetic patients additionally classified according to the presence of macrovascular disease. Forty-four non-diabetic patients with angiografically documented cardiovascular disease (CAD/ AMI) and a further 59 non-diabetic subjects with no angiografical signs of CAD were investigated as genomic background control (n=103). PIA-genotyping was carried out by standard restriction fragment length analysis (RFLA) of PCR amplified lymphocyte template DNA. RESULTS: The overall allelic PlA2- prevalence accounted to 34.8% (39/112) in diabetic patients as compared to 14.6% (15/103) in non-diabetic patients [OR 3.1 (1.6-6.1), p<0.01]. This odds ratio increased to 7.0 (2.5-19.7), (p<0.01) in subjects free of criteria of macrovascular disease. In non-diabetic control subjects without CAD there was an allelic PIA2 frequency of 10.2% (6/59) as compared to 20.5% (9/44) in patients with CAD and a history of AMI being less than either diabetes subgroup. The PIA2 prevalence in the subgroup of diabetes patients with macrovascular complications did not differ from the respective value in patients without macrovascular disease. [29.0% (20/69) vs. 44.2% (19/43)]. CONCLUSION/INTERPRETATION: This study confirms a trendwise association of PlA2 with severe coronary artery disease, but rather suggests an even stronger, highly significant association with the metabolic condition of Type 2 diabetes mellitus. This justifies the speculation that pathways dependent on the platelet alpha(2)beta(3) integrin physiology could be implicated in the pathogenesis of Type 2 diabetes which lends further support to the "common soil" hypothesis of diabetes and vascular disease.

Amino Acid Substitution↗

[Brachytherapy after coronary interventions: current state and future perspectives].

Intracoronary brachytherapy is a novel, meanwhile established therapy. It is currently the only interventional procedure which has proven to effectively reduce the restenosis rates after intervention of long and diffuse in-stent restenosis. For this indication, brachytherapy can be regarded as the current treatment of choice. Randomized studies yield promising results for bypass interventions or interventions in small vessels or diabetic patients. These findings may encourage the decision to perform a percutaneous, transluminal intervention in such high-risk patients. In clinical practice, implantation of new stents in combination with brachytherapy procedures should be avoided as far as possible. In any case, the combined antiaggregatory therapy should be conducted sufficiently long to minimize the danger of late stent thrombosis. Under this treatment, the expected thrombosis rates ar within the range of placebo-treated patients. The length of the radiation source should be sufficient to cover the entire interventional injury length to avoid recurrent edge stenosis. De novo lesions are currently not a routine indication for intracoronary brachytherapy. Although intracoronary brachytherapy may effectively reduce restenosis rates in sufficiently irradiated de novo lesion segments, de novo lesions should be treated only within the set-up of controlled studies. The current available data with a follow-up period of up to 5 years show that intracoronary brachytherapy is also in the mid-term a safe and effective therapy for the reduction of restenosis after coronary interventions.

Angioplasty, Balloon, Coronary↗

Evaluation of metal allergies in patients with coronary stents.

In-stent restenosis is a complication which impairs the success of coronary stenting. Recently, it was supposed that a delayed hypersensitivity reaction to nickel and molybdenum might be one of the triggering factors in in-stent restenosis. We have analyzed the data collected in our centre with respect to this hypothesis. Altogether, 34 patients were investigated (24 male, 10 female). Patch tests were performed with the standard series of the German Contact Dermatitis Research Group and a metal series containing the metal components of 316 L stainless steel. A positive patch test reaction to nickel was observed in 4 (11.8%) patients. None of the patients showed sensitization to the other metals. Retrospective analysis was performed in 20 patients: 2 of these patients had a positive patch test reaction to nickel, one of whom had an in-stent restenosis, and the other not. Restenoses were predominantly observed in patients with negative patch test reactions to nickel (6/18 patients). Out of the patients who were investigated prospectively only one showed sensitization to nickel. Restenosis was observed in 2 patients: neither patient had nickel allergy. Although it still cannot be excluded that metal allergy may play a role in the restenosis process in coronary stenting, there is at present little evidence for it.

Coronary Angiography↗

How big is small?

Explore the source record for details and available documents.

Arteries↗

Prognostic implication of cardiac troponin T increase following stent implantation.

OBJECTIVE: To identify the incidence and clinical significance of myocardial injury following elective stent implantation. DESIGN: Prospective clinical study with 278 consecutive patients undergoing stenting of de novo coronary or saphenous vein graft lesions. Incidence of periprocedural myocardial injury was assessed by analysis of 12 lead ECG, creatine kinase (CK; upper limit of normal (ULN) 70 IU/l for women, 80 IU/l for men), and cardiac troponin T (cTnT; point of care test; threshold 0.1 ng/ml) before and 6, 12, and 24 hours after the intervention. Major adverse cardiac events (MACE: acute myocardial infarction, bypass surgery, and cardiac death) were recorded during clinical follow up (mean (SD) 7.8 (5.3) months). RESULTS: Following elective stenting, the rate of a positive cTnT status was 17.3%, the rate of CK increase of 1-3x ULN 14.7%, the rate of CK increase of > 3x ULN 1.4%, and the rate of Q wave myocardial infarction 0.4%. Cardiac mortality during follow up was higher in patients with postprocedurally increased CK (7.1% v 1.3%, p = 0.01, log rank) and cTnT (9.1% v 0.9%, p < 0.001, log rank). In addition, postprocedurally increased cTnT was associated with a higher overall incidence of MACE (13.1% v 4.0%, p < 0.01, log rank) and was identified as an independent factor for MACE during follow up (hazard ratio 3.27, 95% confidence interval 1.14 to 9.41, p = 0.028). CONCLUSIONS: Following elective stent implantation, a positive cTnT status identified patients at risk of a worse long term outcome. Treatment strategies have to be developed that lead to prognostic improvement by reducing periprocedural myocardial injury.

Biomarkers↗

Plaque distribution and vascular remodeling of ruptured and nonruptured coronary plaques in the same vessel: an intravascular ultrasound study in vivo.

OBJECTIVES: This study was designed to identify potential differences between the intravascular ultrasound (IVUS) characteristics of spontaneously ruptured and nonruptured coronary plaques. BACKGROUND: The identification of vulnerable plaques in vivo may allow targeted prevention of acute coronary events and more effective evaluation of novel therapeutic approaches. METHODS: Intravascular ultrasound was used to identify 29 ruptured plaques in arteries containing another nonruptured plaque in an adjacent segment. Intravascular ultrasound characteristics of these plaques were compared with plaques of computer-matched controls without evidence of plaque rupture. Plaque distribution was assessed by measuring the eccentricity of lumen location (inside the total vessel). Lumen cross-sectional area narrowing was calculated as [1 - (target/reference lumen area)] x 100%. A remodeling index was calculated as lesion/reference arterial area (>1.05 = compensatory enlargement, <0.95 = shrinkage). RESULTS: Among the three groups of plaques, there was no significant difference in quantitative angiographic parameters, IVUS reference dimensions and IVUS lumen cross-sectional area narrowing. There was a difference in plaque distribution; lumen location by IVUS was significantly more eccentric in ruptured than in nonruptured (p = 0.002) and control plaques (p < 0.0001). The arc of disease-free vessel wall was larger in ruptured than in control plaques (p < 0.0001). The remodeling pattern of ruptured and nonruptured plaques differed significantly from that of the control plaques (p = 0.0001 and 0.003); compensatory enlargement was found in 66%, 48%, and 17%, whereas shrinkage was found in 7%, 10% and 48%, respectively. CONCLUSIONS: Intravascular ultrasound assessment of plaque distribution and vascular remodeling may help to classify plaques with the highest probability of spontaneous rupture.

Coronary Artery Disease↗

Abnormal coronary flow velocity reserve after coronary intervention is associated with cardiac marker elevation.

BACKGROUND: Residual reduction of relative coronary flow velocity reserve (rCVR) after successful coronary intervention has been related to microvascular impairment. However, the incidence of cardiac enzyme elevation as a surrogate marker of an underlying embolic myocardial injury in these cases has not been studied. METHODS AND RESULTS: A series of 55 consecutive patients with successful coronary stenting, periprocedural intracoronary Doppler analysis, and determination of creatine kinase (CK; upper limit of normal [ULN] for women 70 IU/L, for men 80 IU/L) and cardiac troponin T (cTnT; bedside test, threshold 0.1 ng/mL) before and 6, 12, and 24 hours after intervention were studied. Postprocedural rCVR was the only intracoronary Doppler parameter that independently correlated with cTnT (r=-0.498, P<0.001) and CK outcome (r=-0.406, P=0.002). Receiver operating characteristic analysis identified a postprocedural rCVR of 0.78 as the best discriminating value, with a sensitivity of 83.3% and 69.2% and a specificity of 79.1% and 76.2% for detection of cTnT and CK elevation, respectively. Stratified according to this cutoff value, the incidence of cTnT elevation was 52.6% in patients with (n=19) and 5.6% in patients without (n=36) a postprocedural rCVR <0.78 (P<0.001), associated with a CK elevation >1 times the ULN in 36.8% and 5.6% (P=0.005) of patients, respectively. CONCLUSIONS: Cardiac marker elevation can frequently be found after coronary procedures that are associated with a persistent reduction of rCVR, indicating procedural embolization of atherothrombotic debris with microvascular impairment and myocardial injury as a potential underlying mechanism.

Aged↗

[Biochemical markers of ischemic and non-ischemic myocardial damage].

BACKGROUND: Biochemical markers have been an integrative part of non-invasive diagnostic strategies in cardiology for nearly 50 years, experiencing a renascence by the recently acknowledged prognostic potential of cardiac troponins in acute coronary syndromes. DIAGNOSIS: According to the guidelines of the National Academy of Clinical Biochemistry and the International Federation of Clinical Chemistry cardiac troponin T and cardiac troponin I should be considered as the new "gold markers" of ischemic myocardial injury. One characteristic feature of these new markers is the improved diagnostic potential, reflected by the choice of two cut-off values to distinguish minor myocardial injury from acute myocardial infarction. In addition, cardiac troponins allow risk stratification in the clinical setting of acute coronary syndromes: approximately threefold higher mortality rate for patients with rest angina or ST segment elevation and cardiac troponin elevation on admission. Other indications for cardiac marker analysis are monitoring of therapeutic success in case of invasive and non-invasive reperfusion strategies and non-invasive diagnosis of non-ischemic myocardial injury (myocarditis, cardiac contusion and chemotherapy). CONCLUSION: Biochemical cardiac markers are a useful tool in the diagnosis of both ischemic and non-ischemic myocardial injury. Among these, cardiac troponins seem to become the gold markers for the new millennium.

Angina, Unstable↗

Intracoronary Doppler- and quantitative coronary angiography-derived predictors of major adverse cardiac events after stent implantation.

BACKGROUND: Distal coronary flow velocity reserve (CVR) is significantly improved after a successful balloon angioplasty (PTCA). Furthermore, a postinterventional CVR >2.5 and a percent diameter stenosis (%DS) </=35% are predictive for a low incidence of major adverse cardiac events (MACE) at 6 months of 16%. Similar results are lacking for coronary stenting. METHODS AND RESULTS: In 150 patients, baseline and hyperemic coronary flow velocities were recorded with a Doppler guidewire distal to the target lesion and in an unobstructed reference artery before and after PTCA, after stenting, and at 6 months. Distal CVR and relative CVR (CVR(rel)) were calculated. Logistic regression and receiver operating characteristic analyses were applied to determine prognostic cutoff values of CVR, CVR(rel), %DS, and minimal lumen diameter separately and in combination to predict MACE at 6 months. After stenting, CVR (2.96+/-0.87 versus 2.40+/-0.7; P:=0.001), CVR(rel) (1.02+/-0.24 versus 0.81+/-0.24; P:=0.001), and minimal lumen diameter (2.98+/-0.56 versus 2.11+/-0.74 mm; P:=0.001) were significantly higher than after PTCA. Thirty-three patients developed MACE. A postinterventional CVR(rel)>0.88 was the best single predictor of MACE, with an incidence of 6.8%, whereas the combination of a CVR(rel)>0.88 and a %DS </=11.2% predicted an incidence of MACE of 1.5%. CONCLUSIONS: Measurement of CVR(rel) and %DS after stent implantation are best suitable to predict MACE at 6 months.

Aged↗

Early clinical experience with the 6 French Angio-Seal device: immediate closure of femoral puncture sites after diagnostic and interventional coronary procedures.

The objective of this study was to assess the early safety and efficacy of the novel 6 Fr Angio-Seal device for routine clinical use after diagnostic cardiac catheterization and coronary angioplasty. In a prospective study, we used the 6 Fr Angio-Seal device in 180 consecutive patients (131 male, 49 female, mean age 60.7 years) for closure of femoral arterial puncture sites immediately after diagnostic (n = 108) or interventional (n = 72) coronary procedures independent of the coagulation status. All patients were monitored for 24 hr after the procedure and followed for 30 days. The closure device was successfully deployed in 95.4% after diagnostic catheterization versus 98.6% after coronary angioplasty (P = 0.963). Immediate hemostasis was achieved in 91.5% versus 90.1% of the patients (P = 0.993). Major complications were observed 1.9% versus 2.8% of the patients (P = 0.885). During 30-day follow-up, no late events or complications were reported. The 6 Fr Angio-Seal device is a safe and effective device that allows for immediate closure of femoral puncture sites after both diagnostic and interventional procedures with a low rate of major complications.

Adult↗

Assessment of coronary morphology and flow in a patient with Guillain-Barré syndrome and ST-segment elevation.

Patients with Guillain-Barré syndrome often have cardiac disturbances as a manifestation of autonomic dysfunction. Such abnormalities consist of arrhythmias and disturbances of heart rate and blood pressure. We report a case of a patient with Guillain-Barré syndrome who developed ST-segment elevation in the inferolateral leads, suggestive of an acute coronary syndrome. Cardiac catheterization revealed angiographically normal coronary arteries. Intracoronary ultrasound was also normal. Intracoronary Doppler flow measurements revealed an elevated baseline coronary flow velocity of up to 41 cm/s and decreased coronary flow reserve, particularly in the left circumflex artery. Myopericarditis as cause of the electrocardiographic changes could be ruled out by echocardiography and endomyocardial biopsy. We postulate that the intracoronary Doppler findings are caused by autonomic dysfunction with decrease of coronary resistance and redistribution of the transmural myocardial blood flow.

Autonomic Nervous System Diseases↗

[Late stent thrombosis after intracoronary brachytherapy. A case report and review of the literature].

Intracoronary irradiation is currently the most promising approach to reduce restenosis after percutaneous transluminal coronary angioplasty. Meanwhile numerous data are available concerning efficacy and safety of this novel method. These data confirm the results of preclinical studies that reported a dramatic reduction of neo-intima proliferation and negative remodeling. However, the number of reports on an elevated incidence of late stent thrombosis (> 30 days post intervention) are increasing. It is commonly suggested that the delayed neo-intima formation within vascular stents is responsible for this new phenomenon. We report the case of a 48-year-old man who underwent coronary irradiation therapy after stent placement in a de-novo/restenotic lesion. Despite an explicit recommendation of a combined anti-aggregatory therapy consisting of ticlopidine and acetysalicylic acid for at least 6 months, ticlopidine was withdrawn after 4 weeks. Two weeks later, the patient was readmitted to an external hospital with an acute myocardial infarction and successfully treated with thrombolysis. The angiographic and intravascular control, which was conducted after another two weeks, showed absolutely no neointima formation within the implanted stent. Thus, a late thrombotic occlusion of the implanted stent appears most likely to be the cause underlying the myocardial infarction. This case underlines, together with other existing reports, the importance of a prolonged, combined anti-aggregatory therapy after stent placement and subsequent intracoronary irradiation.

Angina Pectoris↗

Myocardial lactate release after intracoronary verapamil application in humans: acute effects of intracoronary verapamil on systemic and coronary hemodynamics, myocardial metabolism, and norepinephrine levels.

Coronary and systemic hemodynamic effects of verapamil have been investigated previously in detail. The acute impact of intracoronary verapamil on coronary hemodynamics has, however, not been correlated to simultaneously changes in myocardial metabolism or norepinephrine levels in humans. After bolus application of 1 mg verapamil into the left coronary artery of 52 patients scheduled for routine coronary angiography, heart rate (HR) remained unchanged, whereas mean arterial blood pressure (MAP) decreased (93.8 +/- 14.9 mmHg to 85.1 +/- 13.7 mmHg, p = 0.001). Coronary blood flow (CBF), calculated from intracoronary Doppler measurements and quantitative coronary angiography, increased after verapamil administration (28.5 +/- 16.7 ml/min to 66.2 +/- 41.8 ml/min, p < 0.001), whereas coronary vascular resistance index (CVRI) decreased (1.43 +/- 0.92 to 0.46 +/- 0.23, p < 0.001). Blood samples, taken simultaneously from the aorta (Ao) and coronary sinus (CS) at baseline and at maximal flow velocity, showed an increase in norepinephrine concentrations in Ao (209 +/- 151 ng/l to 283 +/- 195 ng/l, p < 0.001) and CS (233 +/- 162 ng/l to 323 +/- 248 ng/l, p = 0.004). Myocardial metabolism of pyruvate and free fatty acids were not affected. Glucose release was augmented and initial lactate consumption changed to a net lactate release into the CS (Ao to CS differences: glucose: -1.92 +/- 9.9 mg/dl to -12.8 +/- 22.8 mg/dl, p < 0.001; lactate: 0.07 +/- 0.2 mmol/l to -0.08 +/- 0.3 mmol/l, p = 0.001). Similar results were obtained for the extraction ratios and flux of these metabolites. There was a weak correlation between the increase in CBF and lactate release into the CS. This is the first report of unexpected myocardial lactate release following intracoronary verapamil administration in humans. This lactate release was paralleled by an increased glucose release into the CS at an unchanged metabolism of free fatty acids and pyruvate. One explanation for this unexplained lactate release during increased coronary blood flow might be a wash out phenomenon of lactate from previous ischemic areas, other explanations might be the induction of paradox myocardial ischemia and/or a steal effect. Further studies are necessary to explain these unexpected findings of increased coronary flow and myocardial lactate release. Until reliable explanations are pending, studies using only lactate release as a marker of myocardial ischemia, without taken coronary and systemic hemodynamic parameters into account, should be interpreted with caution.

Adult↗

The immediate and long-term effect of optimal balloon angioplasty on the absolute coronary blood flow velocity reserve. A subanalysis of the DEBATE study. Doppler Endpoints Balloon Angioplasty Trial Europe.

BACKGROUND: There are limited data regarding the immediate and long-term effect of balloon angioplasty on the coronary flow reserve evaluated in a multicentre setting. METHODS AND RESULTS: A total of 86 patients with one-vessel disease and normal left ventricular function were analysed before and after optimal balloon angioplasty (diameter stenosis <35%) and at 6-month follow-up. Coronary flow reserve was assessed with a Doppler guide wire. A low coronary flow reserve ( 2.5 (46% vs 23% and 36% vs 16%, respectively; P<0.05) due to a trend towards restenosis (29% vs 16%; P=0.15) or a low coronary flow reserve at follow-up due to persistent elevated baseline blood flow velocity. Patients without restenosis showed a decrease or increase of coronary flow reserve during follow-up, determined by alterations of hyperaemic blood flow velocity. CONCLUSIONS: Patients with an impaired coronary flow reserve directly after optimal balloon angioplasty showed a higher target lesion revascularization rate compared to patients with a coronary flow reserve >2.5. This patient group consists of patients prone to develop restenosis, while other patients are characterized by a persistently low coronary flow reserve, probably secondary to disturbed autoregulation and/or diffuse mild coronary atherosclerosis. Coronary flow reserve alterations in patients without restenosis were related to changes in hyperaemic blood flow velocity, suggesting that this phenomenon relates to epicardial remodelling.

Adult↗

Increased heterogeneity of coronary perfusion in patients with early coronary atherosclerosis.

BACKGROUND: In patients with typical angina but angiographically normal coronary arteries, abnormal vasomotor function is assumed to be a major underlying cause. However, data on this issue are conflicting, and recent studies suggest that fluid dynamic abnormalities exist in these patients. The aim of the study was to evaluate whether early stages of atherosclerosis are characterized by alterations of baseline coronary hemodynamics and endothelium-independent vasomotion. Besides established intracoronary Doppler parameters, heterogeneity of perfusion was assessed and related to early signs of atherosclerosis as determined by electron-beam computed tomography (EBCT). METHODS: In 59 patients with typical angina and angiographically normal or near-normal coronary arteries, intracoronary Doppler measurements were performed in all 3 major coronary arteries. Baseline average peak velocity (bAPV) and hyperemic average peak velocity (hAPV) in response to intracoronary injection of adenosine were measured, and coronary flow velocity reserve (CFVR) was calculated. Heterogeneity was assessed as variability of bAPV, hAPV, and CFVR and was calculated as (STD/MEAN). 100. Doppler data were analyzed according to tertiles of the EBCT-derived Agatston calcium score (ie, score 0-1 [lowest tertile], 2-28 [medium tertile], and >28 [highest tertile]). RESULTS: The mean EBCT-derived Agatston calcium score was 49 +/- 107. No coronary calcium was observed in 17 (29%) patients. The mean values of bAPV, hAPV, and CFVR were not different between the calcium score tertiles. However, patients in the highest tertile had a significantly increased variability index of bAPV (29.6% +/- 11.6%) compared with patients in the lowest tertile (13.4% +/- 7.3%, P <.0001). Variability of CFVR was also increased in these patients (15.5% +/- 11.7% vs 10.5% +/- 4.0%, P =.03). CONCLUSION: These results indicate that early stages of atherosclerosis are characterized by microvascular abnormalities that do not uniformly affect the myocardium but are heterogeneous. The high variability of baseline coronary flow velocity with increasing coronary calcium suggests that in patients with early stages of atherosclerosis fluid dynamic effects may play a crucial role even in the absence of angiographically appreciable epicardial stenoses.

Adenosine↗

Enhanced epinephrine-induced platelet aggregation in individuals carrying the G protein beta3 subunit 825T allele.

The 825T allele of a common C825T polymorphism in the gene encoding the beta3 subunit of heterotrimeric G proteins is associated with enhanced activation of pertussis toxin (PTX)-sensitive G proteins. We investigated responses of human platelets upon stimulation with epinephrine, which activates PTX-sensitive G proteins, and with agonists which activate additionally, or exclusively PTX-insensitive pathways. Slopes and maximum of the secondary aggregation were significantly enhanced in platelets from 825T allele carriers after epinephrine, and after combined epinephrine/ADP. This effect was more pronounced after inhibition of the cyclooxygenase-2 pathway by acetylsalicylic acid. This phenomenon appeared independent of platelet secretion, or inhibition of the adenylyl cyclase.

15-Hydroxy-11 alpha,9 alpha-(epoxymethano)prosta-5↗

Interventional therapy of vascular complications caused by the hemostatic puncture closure device angio-seal.

The hemostatic puncture closure device Angio-Seal is a quick, safe, and easy-to-use system, allowing rapid sealing of the vascular access site following coronary angiography and interventional procedures. It is advantageous for patients in whom early mobilization is desired and may therefore decrease hospital costs. Despite the documented low complication rate, there are some specific problems. Reporting on five cases, we describe problems in diagnosis and possible interventional therapy of Angio-Seal-associated complications such as stenosis, occlusion, or peripheral embolism. Our experience led to the concept of precise diagnosis in any patient with leg symptoms and early interventional treatment with the aim of complete removal of the intra-arterial parts of the Angio-Seal device. Any delay in diagnosis and treatment increases the risk of additional thrombotic occlusion. Spontaneous dissolution of the Angio-Seal sponge limits interventional possibilities of complete removal. Cathet. Cardiovasc. Intervent. 49:142-147, 2000.

Adult↗