Search PubMed⌕ Search

PubMed · 9161187

Technical note. Modulation transfer function analysis of a newly revised rotational panoramic machine.

Abstract

OBJECTIVES: To determine the modulation transfer function (MTF) and noise equivalent passband (NE) values for a newly revised rotational panoramic X-ray machine, the PC-1000 (Panoramic Corp., Fort Wayne, Indiana, USA). METHODS: Images of a 10 microns test slit were taken at various locations along the X-ray beam projection path using a Lanex Regular/T-Mat G image receptor. Line spread functions were obtained at specific beam paths by scanning slit images with a microdensitometer. RESULTS: MTF values were highest around the central plane of the image layer, with a maximum near the centre of 0.25 at 4 cycles/mm. The NE values near the central plane of image layer were 1.4 cycles/mm. MTF and NE values in the anterior region were low, 0.2 and 1.2, respectively. The width of the image layer was narrower in the anterior and wider in the posterior segments. Rapid decreases in MTF and NE values were found on the X-ray tube side compared with the receptor side of the central plane. Using a spatial frequency of 0.25 MTF the shape of the image layer was coincident with that determined visually. CONCLUSION: On the basis of the MTF and NE values the image resolution produced by this machine is considered acceptable for panoramic dental radiography.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y Hayakawa, F E Eraso, W C Scarfe, A G Farman, K Nishikawa, K Kuroyanagi, M Smith. 1996. Technical note. Modulation transfer function analysis of a newly revised rotational panoramic machine.. https://doi.org/10.1259/dmfr.25.5.9161187

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Content uniformity and assay requirements in current regulations.

The acceptance of a tablet batch is based both on the content uniformity test and on the assay. It is shown that these two characteristics are not independent, and the acceptance criteria for them are not even consistent. For content uniformity range three methods of calculation are compared: the present European Pharmacopoeia method, a tolerance range method with improved k tolerance factor and a one-way random effects analysis of variance model. To resolve the inconsistency several options are discussed: applying the holistic content uniformity range alone; using content uniformity standard deviation and assay mean simultaneously or applying a criterion based on Taguchi's quadratic loss function.

Mathematics↗

Stable time filtering of strongly unstable spatially extended systems.

Many contemporary problems in science involve making predictions based on partial observation of extremely complicated spatially extended systems with many degrees of freedom and with physical instabilities on both large and small scale. Various new ensemble filtering strategies have been developed recently for these applications, and new mathematical issues arise. Because ensembles are extremely expensive to generate, one such issue is whether it is possible under appropriate circumstances to take long time steps in an explicit difference scheme and violate the classical Courant-Friedrichs-Lewy (CFL)-stability condition yet obtain stable accurate filtering by using the observations. These issues are explored here both through elementary mathematical theory, which provides simple guidelines, and the detailed study of a prototype model. The prototype model involves an unstable finite difference scheme for a convection-diffusion equation, and it is demonstrated below that appropriate observations can result in stable accurate filtering of this strongly unstable spatially extended system.

Mathematics↗