Search PubMed⌕ Search

PubMed · 9019262

[Mechanical digestive system suturing devices].

Abstract

Between 1994 (December)-1996 (May) 150 patients have been operated on using one or many stapling devices. The staplers disposable to us were the "Linear Cutter" or GIA (Gastrointestinal Anastomosis), "Linear Stapler" (TA) and "Intraluminal Circular Stapler" or EEA (end-to-end anastomosis) types, produced by ETHICON (Johnson and Johnson Ltd. Company). The principles operations performed were various digestive resections, intervisceralis anastomosis and interventions of reconstructions (in oesophagus surgery, ileal pouch etc.). The advantages of staplers applications are: a) the reduction of the time of operation, of the anesthesia, of the blood loss; b) a soft manipulation of the tissues; c) a smaller inflammatory reaction and the prevention of intraoperative septic contamination and d) a better and faster take back of the functionality of the anastomosis. There were only 4 intraoperative haemorrhages easy controllable. Postoperative complications: a) 3 haemorrhages medically treated; b) immediate leakage 1 patient after colorectoanastomosis, treated by Hartman colostomy; precocious, 7 patients and after 4-6 month, 2 patients. Corrective iterative interventions were necessary only in 5 patients. The operative mortality-1 patient, the cause of death being a bronhopneumonia after a radical oesophagectomy with oesophagoplasty (oesophageal cancer). There was not postoperative mortality depending of stapling application. We don't observed late postoperative complications like stenosis of various anastomosis, quoted in the literature, because the time of following of our 150 patients is too short (maximum 18 months). The conclusions are that the stapling devices are a real surgical progress with the conditions of a correct indication and adequate tactics and operative technique. The economical effort is justified and entirely compensated by the major benefits obtained for the patients.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Popovici, I Popescu, M I Ionescu, C Vasilescu, G Mitulescu, C A Iliescu. [Mechanical digestive system suturing devices].. https://pubmed.ncbi.nlm.nih.gov/9019262/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Revival of the side-to-side approach for distal coronary anastomosis.

Side-to-side anastomosis was employed by just ten proportional stitches while performing distal anastomosis during coronary artery surgery. This technique is simple and quick. Here this simple technique is described in detail and the postoperative status of grafted conduits is reported.

Anastomosis, Surgical↗

Review article: Indeterminate colitis--definition, diagnosis and management.

BACKGROUND: The term indeterminate colitis is imprecise and without a generally accepted definition. Nevertheless, it is a term that is commonly used by gastroenterologists, pathologists and surgeons. AIM: To offer an opinion supported by published data, about the appropriate use of the term indeterminate colitis by addressing a series of questions. METHODS: A PubMed database search was performed using the keywords, 'colitis' and 'inflammatory bowel disease' each combined individually with the following adjectives: 'indeterminate', 'unclassified', 'undefined', 'undiagnosed' and 'non-specific'. RESULTS: There is no generally accepted definition of indeterminate colitis. All current applications of the term rely on exclusionary criteria and there is no confirmatory diagnostic test. Nevertheless, the diagnosis of indeterminate colitis appears to be durable in a subgroup of patients, suggesting that this group represents a unique phenotype. CONCLUSIONS: Indeterminate colitis has expanded from a strictly defined, postcolectomy pathological diagnosis to become, in addition, a clinical diagnosis without generally accepted criteria. A diagnosis of indeterminate colitis should be qualified with descriptors for the diagnostic criteria applied.

Anastomosis, Surgical↗

Acellular dermal matrix grafts for prevention of microarterial thrombophlebitis.

OBJECTIVE: To examine the role of acellular dermal matrix grafts for prevention of microarterial anastomotic thrombophlebitis. DESIGN: Bilateral femoral artery microvascular anastomoses were created in the field of established wounds infected with Staphylococcus aureus in 12 rats. In each animal, 1 femoral microarterial anastomosis was wrapped with an acellular dermal matrix graft, and the contralateral femoral anastomosis was left unprotected. The incidence of femoral artery thrombosis was determined after 4 days by wound reexploration. SETTING: David Geffen School of Medicine, University of California, Los Angeles. MAIN OUTCOME MEASURE: The patency of femoral artery anastomoses was determined after 4 days by wound reexploration. RESULTS: The incidence of femoral artery thrombosis in vessels wrapped with acellular dermal matrix grafts was 17%. The incidence of femoral artery thrombosis in unprotected vessels was 100%. This difference was statistically significant (P<.05). CONCLUSION: Acellular dermal matrix grafts seem to have a protective effect in the prevention of acute thrombophlebitis when arterial microvascular anastomoses are performed in infected surgical fields.

Anastomosis, Surgical↗