Search PubMed⌕ Search

PubMed · 8992208

Frequency resolved single-shot MR imaging using stochastic k-space trajectories.

Abstract

A new single-shot stochastic imaging technique with a random k-space path that provides very selective filtering with respect to chemical shift or off-resonance signals of the investigated tissue is proposed. It is demonstrated that in stochastic imaging only on-resonance compartments are visible whereas frequency shifted compartments cancel to noise that is distributed over the whole image. This method can be used as a single-shot chemical shift selective imaging technique and allows to calculate frequency resolved spectra for each spatial position of the image based on a single signal acquisition. The single-shot stochastic imaging sequence makes high demands on the gradient system and the theoretical k-space trajectory is distorted by imperfect gradient performance. Therefore an additional k-space guided imaging technique that uses the true, measured k-space trajectory to correct artifacts generated by eddy currents and delay times of the rapid switched gradients is presented. In vitro and in vivo measurements demonstrate the successful implementation of single-shot stochastic imaging on a conventional MR scanner with unshielded gradient systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Scheffler, J Hennig. 1996. Frequency resolved single-shot MR imaging using stochastic k-space trajectories.. https://doi.org/10.1002/mrm.1910350417

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗