Search PubMed⌕ Search

Biomedical subjects

K Scheffler

Publications and source records attributed to K Scheffler.

At least 19 recordsLinked to original sources

Effect of diffusion in inhomogeneous magnetic fields on balanced steady-state free precession.

In this work, the effects of susceptibility variation from dilute, micron-sized spherical field perturbers and diffusion on balanced steady-state free precession (bSSFP) are analyzed. Predictions from Monte Carlo simulations are in good agreement with experiments and reveal that, for diffusing protons, susceptibility variation becomes apparent as a reduction in the overall bSSFP signal intensity. This reduction depends on microsphere parameters (radius and susceptibility difference), as well as on sequence-related parameters (repetition time and flip angle) and on relaxation times. Specific Monte Carlo results from one set of parameter values can be extrapolated to another set of values by means of a scaling law and a substitution model. The scaling law, derived from the Bloch-Torrey equation, captures the dependencies of bSSFP signal reduction on susceptibility and diffusion-related changes and on repetition time, whereas the substitution model describes those on flip angle and relaxation times.

Algorithms↗

Alternating repetition time balanced steady state free precession.

A novel balanced SSFP technique for the separation or suppression of different resonance frequencies (e.g., fat suppression) is presented. The method is based on applying two alternating and different repetition times, TR(1) and TR(2). This RF scheme manipulates the sensitivity of balanced SSFP to off-resonance effects by a modification of the frequency response profile. Starting from a general approach, an optimally broadened stopband within the frequency response function is designed. This is achieved with a TR(2) being one third of TR(1) and an RF-pulse phase increment of 90 degrees . With this approach TR(2) is too short ( approximately 1 ms) to switch imaging gradients and is only used to change the frequency sensitivity. Without a significant change of the spectral position of the stopband, TR(1) can be varied over a range of values ( approximately 2.5-4.5 ms) while TR(2) and phase cycling is kept constant. On-resonance spins show a magnetization behavior similar to balanced SSFP, but with maximal magnetization at flip angles about 10 degrees lower than in balanced SSFP. The total scan time is increased by about 30% compared to conventional balanced SSFP. The new technique was applied on phantoms and volunteers to produce rapid, fat suppressed images.

Humans↗

Balanced alternating steady-state elastography.

A conventional balanced steady-state free precession (b-SSFP) sequence scheme was modified such that the dynamic equilibrium becomes very sensitive to small cyclic displacements, generating two distinct and alternating steady states. This novel technique is proposed for the visualization of propagating transverse acoustic shear waves, as used in MR elastography (MRE) to determine the mechanical properties of materials or in vivo soft tissue. Experiments with tissue-like agarose gel phantoms and simulations demonstrate that the novel sequence offers an increase in phase sensitivity by about one order in magnitude compared to standard motion-encoding methods. In addition, the new method benefits from the very short acquisition times achieved by b-SSFP protocols.

Artifacts↗

On the origin of apparent low tissue signals in balanced SSFP.

Balanced steady-state free precession (bSSFP) has become increasingly important in clinical applications. Its signal properties have been investigated over several years by many groups, and various critical factors for bSSFP signal intensity and stability, such as off-resonances, flow, and eddy currents, have been identified. It is generally accepted that bSSFP signal intensity is a function of relaxation times, excitation angles, and spin densities only. While this is true for simple phantoms, it appears that signals from tissues are significantly less intense than predicted by theory. This work demonstrates that the molecular origin of this apparent signal reduction is due to on-resonance magnetization transfer (MT). High flip angles in combination with very short repetition times (TRs), as commonly used for bSSFP, lead to a considerable saturation in the fraction of macromolecular (MM) pool protons. As a result, bSSFP signal is strongly attenuated by up to a factor of 2 in the human brain compared to the signal expected from theory.

Algorithms↗

A Bayesian model comparison approach to inferring positive selection.

A popular approach to detecting positive selection is to estimate the parameters of a probabilistic model of codon evolution and perform inference based on its maximum likelihood parameter values. This approach has been evaluated intensively in a number of simulation studies and found to be robust when the available data set is large. However, uncertainties in the estimated parameter values can lead to errors in the inference, especially when the data set is small or there is insufficient divergence between the sequences. We introduce a Bayesian model comparison approach to infer whether the sequence as a whole contains sites at which the rate of nonsynonymous substitution is greater than the rate of synonymous substitution. We incorporated this probabilistic model comparison into a Bayesian approach to site-specific inference of positive selection. Using simulated sequences, we compared this approach to the commonly used empirical Bayes approach and investigated the effect of tree length on the performance of both methods. We found that the Bayesian approach outperforms the empirical Bayes method when the amount of sequence divergence is small and is less prone to false-positive inference when the sequences are saturated, while the results are indistinguishable for intermediate levels of sequence divergence.

Bayes Theorem↗

Analysis and compensation of eddy currents in balanced SSFP.

Balanced steady-state free precession (SSFP) completely compensates for all gradients within each repetition time (TR), and is thus very sensitive to any magnetic field imperfection that disturbs the perfectly balanced acquisition scheme. It is demonstrated that balanced SSFP is especially sensitive to changing eddy currents that are induced by stepwise changing phase-encoding (PE) gradients. In contrast to the linear k-space trajectory, which has small variations between consecutive encoding steps, other encoding schemes (e.g., centric, random, or segmented orderings) exhibit significant jumps in k-space between adjacent PE steps, and consequently induce rapidly changing eddy currents. The resulting disturbances induce significant image artifacts, such that compensation strategies are essential when nonlinear PE schemes are applied. Although direct annihilation of the induced eddy currents by additional, opposing magnetic fields has been investigated, it is limited by uncertainty regarding the time evolution of induced eddy currents. A generic (and thus system-unrelated) compensation strategy is proposed that consists of "pairing" of consecutive PE steps. Another approach is based on partial dephasing along the slice direction that annihilates eddy-current-induced signal oscillations. Both pairing of the PE steps and "through-slice equilibration" are easy to implement and allow the use of arbitrary k-space trajectories for balanced SSFP.

Algorithms↗

Double average parallel steady-state free precession imaging: optimized eddy current and transient oscillation compensation.

Balanced steady-state free precession (SSFP) imaging is sensitive to off-resonance effects, which can lead to considerable artifacts during a transient phase following magnetization preparation or steady-state interruption. In addition, nonlinear k-space encoding is required if contrast-relevant k-space regions need to be acquired at specific delays following magnetization preparation or for transient artifact reduction in cardiac-gated k-space segmented CINE imaging. Such trajectories are problematic for balanced SSFP imaging due to nonconstant eddy current effects and resulting disruption of the steady state. In this work, a novel acquisition strategy for balanced SSFP imaging is presented that utilizes scan time reduction by parallel imaging for optimized "double average" eddy current compensation and artifact reduction during the transient phase following steady-state storage and magnetization preparation. Double average parallel SSFP imaging was applied to k-space segmented CINE SSFP tagging as well as nongated centrically encoded SSFP imaging. Phantom and human studies exhibit substantial reduction in steady-state storage and eddy current artifacts while maintaining spatial resolution, signal-to-noise ratio, and similar total scan time of a standard SSFP acquisition. The proposed technique can easily be extended to other acquisition schemes that would benefit from nonlinear reordering schemes and/or rely on interruption of the balanced SSFP steady state.

Algorithms↗

Flow compensation in balanced SSFP sequences.

In balanced steady-state free precession (b-SSFP) sequences, uncompensated first-order moments of encoding gradients induce a nonconstant phase evolution for moving spins within the excitation train, resulting in signal loss and image artifacts. To restore these flow-related phase perturbations, "pairing" of consecutive phase-encoding (PE) steps is compared with a fully flow-compensated sequence using compensating gradient waveforms along all three encoding directions. In volunteer studies, the quality of images acquired with the "pairing" technique was comparable to that of images obtained with the fully flow-compensated technique, regardless of the selected view-ordering scheme used for data acquisition. Nevertheless, the results of phantom experiments indicate that the pairing technique becomes ineffective at flow velocities exceeding roughly 0.5-1 m/s. Consequently, the additional scan time required to null the first gradient moments in a flow-compensated b-SSFP sequence makes the "pairing" technique preferable for applications in which slow to moderate flow velocities can be expected.

Algorithms↗

Frontocortical N-acetylaspartate reduction associated with long-term i.v. heroin use.

To examine possible metabolic frontal lobe alterations in i.v. heroin-dependent patients with different histories of concomitant substance use, N-acetylaspartate (NAA), a putative marker of neuronal viability, was measured by (1)H-MRS. Compared with controls, NAA levels in patients were reduced by 7% in gray matter (p = 0.015) but not in white matter. To what extent comorbid conditions or substance use, including alcohol, contributed to these frontocortical metabolic changes remains to be elucidated.

Adult↗

Fast 31P chemical shift imaging using SSFP methods.

Steady-state free precession (SSFP) methods have been very successful due to their high signal and short imaging times. These properties make them good candidates for applications that intrinsically suffer from low signal such as low gamma nuclei imaging. A new chemical shift imaging (CSI) technique based on the SSFP signal formation has been implemented and applied to (31)P. The signal properties of the SSFP CSI method have been evaluated and the steady-state signal of (31)P has been measured in human muscles. Due to the T(2) and T(1) signal dependence of SSFP, the steady-state signal mainly consists of phosphocreatine (PCr). The technique allows fast CSI acquisitions with high SNR of the PCr signal. The SNR gain for PCr over a FLASH-based CSI method is approx. 4-5. Fast in vivo CSI of human muscle with subcentimeter resolution and high SNR is demonstrated at 2 T.

Magnetic Resonance Imaging↗

Dynamic time-resolved contrast-enhanced two-dimensional MR projection angiography of the pulmonary circulation: standard technique and clinical applications.

OBJECTIVE: Time-resolved pulmonary two-dimensional MR projection angiography is a fast acquisition technique that allows the generation of dynamic projection angiograms by a method similar to that used to generate digital subtraction angiograms. MR images are obtained after subtracting the mask defined at the beginning of the sequence from later images, thus generating time-resolved continuous projection angiograms that depict the passage of a bolus through the pulmonary circulation. This article describes the application of this novel technique in three patients with pathologic conditions not previously described with this modality and two control subjects. CONCLUSION: The analysis of the findings on dynamic time-resolved contrast-enhanced two-dimensional MR projection angiography shows that this technique is useful not only in revealing morphologic changes associated with pulmonary disorders but also in following the passage of the bolus through the cardiopulmonary circulation. The latter capability allows qualitative detection of normal or abnormal pathways and thus is potentially of value in the assessment of several pulmonary disorders.

Adolescent↗

Arterial first pass gadolinium-CM dynamics as a function of several intravenous saline flush and Gd volumes.

This study was performed to evaluate the dynamics of an arterial first pass gadolinium (Gd) contrast medium (CM) bolus at the descending aorta (DAo), depending on various saline flush and Gd volumes. Using an ultra-fast two- dimensional GE-sequence (Siemens Vision, 1.5-T), 200 sequential cross-sectional images of the addressed vessel (1 slice/s) were obtained. Several saline flush volumes (15 mL, 30 mL, and 60 mL) were applied following the administration of 10 mL Gd (single dose) to a group of 4 normal volunteers (body weight 50-55 kg) using a mechanical MR injector (injection rate = 3.0 mL/s). Additionally, when performing a second test series, the saline volume remained constant, while the Gd volumes were varied from half doses to triple doses (5, 10, 20, and 30 mL Gd were given to every volunteer of the group). The signal intensity versus time (SI/T) curve at a measured region of interest (ROI) within the DAo was calculated. The bolus arrival time (BAT), the maximal signal-to-noise ratio (SNR(max)), the bolus time length (BL; 75% and 80% maximum intensity duration), the slope of the SI/T curve, and the areas below the SI/T curve for both the 80% and 75% maximum intensity duration level (INT(80%) and INT(75%)) were calculated. The increase of saline flush volume from 30 to 60 mL caused significant bolus lengthening of approximately 50% (mean BL = 9.5 s, 10.3 s, and 15.4 s for 15 mL, 30 mL, and 60 mL saline flush volumes, respectively, measured as SI/T duration at the 75% SNR(max) level). Using saline flush volumes equal to or higher than 30 mL increased the slope of the SI/T curve. A continuous increase of INT(75%/80%) by using higher saline flush volumes was found. Different saline and Gd volumes did not affect the SNR(max) and the BAT. Only the low dose (0.05 mmol/kg Gd) showed a 17%-21.6% significantly lower SNR(max). The BL and the INT increased mainly by enlarging of applied Gd volume from single to double dose (BL(75%) and INT(75%) were 9.6 s and 1305, 12.3 s and 2121, 38.5 s and 6181, 37.8 s and 6613 for 5, 10, 20, and 30 mL applied Gd volume, respectively). The arterial bolus length benefits from increasing Gd and saline flush volumes due to increased venous bolus length and wash out effects of Gd within the injection site of the vein. Doses larger than a single dose are not needed to increase the SNR in contrast-enhanced magnetic resonance angiography images of the thoracic aorta.

Aorta, Thoracic↗

Slow clearance gadolinium-based extracellular and intravascular contrast media for three-dimensional MR angiography.

The objective of this study was to assess two new slow-clearance contrast media with extracellular and intravascular distribution for magnetic resonance angiography (MRA). Extracellular Gd-DTPA-BC(2)glucA and intravascular Gd(DO3A)(3)-lys(16) were developed within the European Biomed2 MACE Program and compared with two reference compounds, intravascular CMD-A2-Gd-DOTA and extracellular GdDOTA, in 12 rats. Pre- and post-contrast three-dimensional MR (TR/TE = 5 msec/2.2 msec; isotropic voxel size 0.86 mm(3)) was acquired for 2 hours. Signal-to-noise enhancement (DeltaSNR) was calculated. Two minutes after injection, all contrast media provided strong vascular signal enhancement. The DeltaSNR for Gd-DTPA-BC(2)glucA, Gd(DO3A)(3)-lys(16), CMD-A2-Gd-DOTA, and GdDOTA were 13.0 +/- 1.8, 25.0 +/- 3.2, 25.0 +/- 4.0, and 18.0 +/- 3.4, respectively. Gd-DTPA-BC(2)glucA, Gd(DO3A)(3)-lys(16), and CMD-A2-Gd-DOTA cleared slowly from the circulation, whereas GdDOTA cleared rapidly. Vascular DeltaSNR at 2 hours were 2.9 +/- 0.6, 25.0 +/- 3.2, 25.0 +/- 4.0, and 0.4 +/- 1.0. Gd(DO3A)(3)-lys(16) provided strong vascular and minor background enhancement, and thus may be useful for MRA or perfusion imaging. Gd-DTPA-BC(2)glucA produces persistent enhancement of extracellular water, and thus may allow quantification of extracellular distribution volume and assessment of myocardial viability.

Animals↗

T(1) quantification with inversion recovery TrueFISP.

A snapshot FLASH sequence can be used to acquire the time course of longitudinal magnetization during its recovery after a single inversion pulse. However, excitation pulses disturb the exponential recovery of longitudinal magnetization and may produce systematic errors in T(1) estimations. In this context the possibility of using the TrueFISP sequence to detect the recovery of longitudinal magnetization for quantitative T(1) measurements was examined. Experiments were performed on different Gd-doped water phantoms and on humans. T(1) values derived from inversion recovery TrueFISP were in excellent agreement with the single-point method even for flip angles up to 50 degrees. In terms of T(1) accuracy and SNR, the proposed method seems to be superior to the conventional inversion recovery snapshot FLASH technique. Magn Reson Med 45:720-723, 2001.

Brain↗

Magnetization preparation during the steady state: fat-saturated 3D TrueFISP.

A novel fat saturation scheme is proposed which combines spectral fat saturation with a steady-state 3D true Fast Imaging with Steady Precesson (TrueFISP) sequence. Fat saturation consisted of a conventional frequency-selective excitation pulse surrounded by spoiler gradients. This saturation block was periodically repeated within a continuously running TrueFISP sequence. Except for the fat signals, the steady-state signal formation and the resulting image contrast of TrueFISP was not modified by the periodically inserted fat saturation block. This was achieved by a alpha/2 flip-back pulse before the fat saturation block, which stores the established steady-state transverse magnetization as pure longitudinal magnetization. After fat saturation this longitudinal magnetization was excited by a alpha/2 preparation pulse to continue the TrueFISP acquisition. The resulting images show contrast identical to conventional TrueFISP images, but without the usually very bright fat signals. The short repetition time allows acquisition of a 3D data set of the abdomen within a single breath-hold.

Abdomen↗

Hyperechoes.

A novel spin-echo-based refocusing strategy called a hyperecho mechanism is introduced by which the full coherence of magnetization submitted to a sequence of arbitrary RF pulses can be reinstalled. First implementations illustrate the potential of hyperecho formation-especially for Rapid Acquisition with Relaxation Enhancement (RARE) imaging, in which the full image intensity can be retrieved using a fraction of the RF power of a fully refocused sequence. The contribution of stimulated echo pathways to the hyperecho signal leads to an increased signal intensity at a given refocusing time for tissues with T(1) > T(2). For identical T(2) contrast, longer echo times have to be used. Further possibilities for using hyperechoes in gradient-echo sequences and for spin selection are discussed. Magn Reson Med 46:6-12, 2001.

Humans↗