Search PubMed⌕ Search

PubMed · 8889558

Sensitivity, reproducibility, and accuracy in short tandem repeat genotyping using capillary array electrophoresis.

Abstract

The Human Genome Initiative has increased significantly the rate at which disease-causing genes are being mapped and sequenced. New cost-effective methods to locate the genes and to characterize disease-causing mutations require robust, reproducible, and accurate protocols for measuring DNA fragment lengths. Capillary array electrophoresis (CAE) offers rapid, high-resolution separations, high throughput, and sensitive detection. To assess the utility of CAE for the accumulation of genetic information, we tested both sizing accuracy and reproducibility using 48-capillary prototype systems. Two multiplex PCR allelic ladder standards and several CA-repeat markers were analyzed in > 100 runs. Reproducibility in typing > 8000 genotypes reveals a standard deviation of less than 0.2 bp on these systems under optimized conditions. However, sequence-dependent migration anomalies were observed at most simple sequence loci even when analyzed under denaturing conditions, resulting in a systematic bias in estimated fragment sizes. We show here that, by normalizing results to known typing controls, one can obtain locus-averaged accuracies of < 0.06 bp and normalized results within 1 bp of actual. We detect as little as a 1:30,000 dilution of a DNA quantitation standard stained with highly sensitive intercalating dyes, indicating an 80-zeptomole sensitivity limit. However, to obtain reproducible electrokinetic injection, approximately 200 attomoles of fluorescein-labeled DNA is required. These sensitivity limits, sizing precision, and accuracy, together with the 1-hr run times for 48-96 samples, indicate that CAE is a viable method for high-throughput genetic analysis of simple sequence repeat polymorphisms.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E S Mansfield, M Vainer, S Enad, D L Barker, D Harris, E Rappaport, P Fortina. 1996. Sensitivity, reproducibility, and accuracy in short tandem repeat genotyping using capillary array electrophoresis.. https://doi.org/10.1101/gr.6.9.893

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The mechanism of water diffusion in narrow carbon nanotubes.

Carbon nanotubes show exceptional physical properties that render them promising candidates as building blocks for nanostructured materials. Many ambitious applications, ranging from gene therapy to membrane separations, require the delivery of fluids, in particular aqueous solutions, through the interior of carbon nanotubes. To foster these and other applications, it is necessary to understand the thermodynamic and transport properties of water confined within long narrow carbon nanotubes. Previous theoretical work considered either short carbon nanotubes or short periods of time. By conducting molecular dynamics simulations in the microcanonical ensemble for water confined in infinitely long carbon nanotubes of diameter 1.08 nm, we show here that confined water molecules diffuse through a fast ballistic motion mechanism for up to 500 ps at room temperature. By comparing the results obtained for the diffusion of water to those obtained for the diffusion of a reference Lennard-Jones fluid, we prove here that long-lasting hydrogen bonds are responsible for the ballistic diffusion of water clusters in narrow carbon nanotubes, as opposed to spatial mismatches between pore-fluid and fluid-fluid attractive interactions which, as shown previously by others, are responsible for the concerted motion of simple fluids in molecular sieves. Additionally we prove here for the first time that, despite the narrow diameter of the carbon nanotubes considered which may suggest the existence of single-file diffusion, when the trajectories of confined water are studied at time scales in excess of 500 ps, a Fickian-type diffusion mechanism prevails. Our results are important for designing nano fluidic apparatuses to develop, for example, novel drug-delivery devices.

Capillary Action↗

Atomistic simulations of electrowetting in carbon nanotubes.

Electrowetting of carbon nanotubes by mercury was studied using classical molecular dynamics simulations in conjunction with a macroscopic electrocapillarity model. A scaled ab initio mercury dimer potential, optimized to reproduce the mercury liquid density (at 300 K), melting point, and wetting angle on graphite, was selected for the simulations. Wetting of (20,20) single-walled carbon nanotubes by mercury occurs above a threshold voltage of 2.5 V applied across the interface. Both the electrocapillary pressure and imbibition velocity increase quadratically with voltage and can acquire large values, for example, 2.4 kbar and 28 m/s at 4 V, indicating a notable driving force. The observed voltage scaling can be captured by the Lucas-Washburn equation modified to include a wetting-line friction term.

Capillary Action↗