Search PubMed⌕ Search

Biomedical subjects

S Enad

Publications and source records attributed to S Enad.

3 recordsLinked to original sources

Short tandem repeat typing by capillary array electrophoresis: comparison of sizing accuracy and precision using different buffer systems.

Polymorphic microsatellite markers are widely used in gene discovery and mapping, human identification, agricultural genetics, and diagnosis of triplet-repeat expansion disorders. Reliable genotyping of these markers requires polymerase chain reaction (PCR) amplification and very-high-resolution electrophoresis. Capillary array electrophoresis offers extremely fast, high-resolution separation of DNA and more automated sample processing because labor-intensive slab-gel pouring and sample loading are eliminated. We report a simple, reliable procedure for preparing PCR samples for electrokinetic injection into capillaries using a 96-well tray and float dialysis. We developed an improved sizing standard for genotyping and used it to evaluate systematically the sizing accuracy and precision of low-viscosity, replaceable matrix formulations. Our study sizing over 28,000 alleles yielded an average precision of +/- 0.12 bp for fragments up to 350 bp. Low-viscosity formulations permit low-pressure matrix injection (40 psi) and a turnaround time of 70 min for 48-96 samples.

Alleles↗

Versatile low-viscosity sieving matrices for nondenaturing DNA separations using capillary array electrophoresis.

The high-resolution separation of double-stranded DNA (dsDNA) has important applications in physical mapping strategies and in the analysis of polymerase chain reaction (PCR) products. Although high-resolution separations of dsDNA by capillary electrophoresis (CE) have been reported, pulsed fields were required to achieve complete resolution of DNA fragments beyond 23 kilobase pairs (kbp). Here, we report a single formulation to separate a broad range (80 bp-40 kbp) of DNA fragments without the use of pulsed fields. We used a low-viscosity sieving medium (ca. 5 cP, at 25 degrees C) based on polyethyleneoxide (PEO) to separate DNA fragments up to 40 kbp. The matrix contained a mixture of 0.5% PEO (Mn 10(6)) to separate fragments up to 1.5 kbp, combined with 0.1% PEO (Mn 8 x 10(6)) to separate fragments between 1-40 kbp, within a single run. All PEO matrix formulations tested were compatible with a variety of intercalating dyes and with two different capillary wall coating methods. We obtained a detection limit of 25 fg of a 200 bp DNA quantitation standard using Vistra Green in the matrix. Resolution was best using short injection times (5 s or less) and low field strengths (approximately 100 V/cm). Sample runs were complete in 70 min, and use of the capillary array electrophoresis (CAE) system permitted high-throughput DNA analysis. The size range separated is approximately 10 times greater than with conventional slab gel separations.

Coloring Agents↗

Sensitivity, reproducibility, and accuracy in short tandem repeat genotyping using capillary array electrophoresis.

The Human Genome Initiative has increased significantly the rate at which disease-causing genes are being mapped and sequenced. New cost-effective methods to locate the genes and to characterize disease-causing mutations require robust, reproducible, and accurate protocols for measuring DNA fragment lengths. Capillary array electrophoresis (CAE) offers rapid, high-resolution separations, high throughput, and sensitive detection. To assess the utility of CAE for the accumulation of genetic information, we tested both sizing accuracy and reproducibility using 48-capillary prototype systems. Two multiplex PCR allelic ladder standards and several CA-repeat markers were analyzed in > 100 runs. Reproducibility in typing > 8000 genotypes reveals a standard deviation of less than 0.2 bp on these systems under optimized conditions. However, sequence-dependent migration anomalies were observed at most simple sequence loci even when analyzed under denaturing conditions, resulting in a systematic bias in estimated fragment sizes. We show here that, by normalizing results to known typing controls, one can obtain locus-averaged accuracies of < 0.06 bp and normalized results within 1 bp of actual. We detect as little as a 1:30,000 dilution of a DNA quantitation standard stained with highly sensitive intercalating dyes, indicating an 80-zeptomole sensitivity limit. However, to obtain reproducible electrokinetic injection, approximately 200 attomoles of fluorescein-labeled DNA is required. These sensitivity limits, sizing precision, and accuracy, together with the 1-hr run times for 48-96 samples, indicate that CAE is a viable method for high-throughput genetic analysis of simple sequence repeat polymorphisms.

Capillary Action↗