PURPOSE: To determine the ability of new sub-2.0-mm-diameter microlaparoscopes to be used for diagnostic laparoscopy, 28 small-diameter laparoscopies (SDL) were performed during a 4-month-period. METHODS: These cases were performed under general anesthesia, with immediate follow-up confirmation with conventional laparoscopic equipment. An additional 13 SDL procedures were performed under analgosedation plus local anesthesia and were well tolerated by the patients. RESULTS: For the cases performed with conventional laparoscopic control, the visualization results were comparable in 27 of 28 procedures. In the nongeneral anesthesia SDL group, patients were highly satisfied and reported less post-procedural discomfort and minimal scar formation due to the smaller access ports. In this study, two types of microlaparoscopes were used. CONCLUSIONS: While both were adequate, the newer high-resolution microlaparoscope delivered an image much more similar to that which conventional laparoscopy and required little or no change in technique in order to obtain images. With the advent of this new endoscope technology with optics performance comparable to that of conventional laparoscopes, SDL has demonstrated to be a useful procedure for certain clinical indications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

O Bauer, W Küpker, R Felberbaum, W Gerling, K Diedrich. 1996. Small-diameter laparoscopy (SDL) using a microlaparoscope.. https://doi.org/10.1007/bf02070142

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of written feedback by editors on quality of reviews: two randomized trials.

CONTEXT: Better peer review is needed, but proven methods to improve quality are unknown. Our objective was to determine whether written feedback to reviewers improves subsequent reviews. METHODS: Eligible reviewers were randomized to intervention or control (receiving other reviewers' unscored reviews and the editor's decision letter). Study 1 (September 1998-September 2000) included reviewers with a median quality score of 3 or lower; study 2 (April 2000-January 2002), reviewers with median score of 4 or lower. Study 1 was designed with a power of 0.80 to detect a difference in score of 1; study 2, with a power of 0.80 to detect a difference of 0.5. All reviewers were at a peer-reviewed journal (Annals of Emergency Medicine). The main outcome measure was the editor's routine quality rating (1-5) of all reviews (blinded to study enrollment). RESULTS: For study 1, 51 reviewers were eligible and randomized and 35 had sufficient data (182 reviews) for analysis. The mean individual reviewer rating change was 0.16 (95% confidence interval [CI], -0.26 to 0.58) for control and -0.13 (-0.49 to 0.23) for intervention. For study 2, 127 reviewers were eligible and randomized, and 95 had sufficient data (324 reviews). Controls had a mean individual rating change of 0.12 (95% CI, -0.20 to 0.26) and intervention reviewers, 0.06 (-0.19 to 0.31). CONCLUSIONS: In study 1, minimal feedback from editors on review quality had no effect on subsequent performance of poor-quality reviewers, and the trend was toward a negative effect. In study 2, feedback to average reviewers was more extensive and supportive but produced no improvement in reviewer performance. Simple written feedback to reviewers seems to be an ineffective educational tool.

Evaluation Studies as Topic↗