Search PubMed⌕ Search

PubMed · 8768603

[First coronarographies].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F Quijano-Pitman. [First coronarographies].. https://pubmed.ncbi.nlm.nih.gov/8768603/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Central pulmonary artery anatomy in right ventricular outflow tract obstructions.

We reviewed the cine-angiograms of 190 patients with right ventricular outflow tract (RVOT) obstructions for size and anatomy of pulmonary arteries, patent ductus arteriosus (PDA) and major aorto pulmonary collateral arteries (MAPCAs). Patients were grouped into three, Tetralogy of Fallot (TOF) with pulmonary atresia (group 1, N=86), TOF with pulmonary stenosis (group 2, N=97) and 7 cases of pulmonary atresia with intact interventricular septum (group 3). Out of 86 patients in group 1, 49 had PDA alone, 30 had MAPCAs alone, six had both and one had none. In group 2, 31 patients had persistent PDA and one patient had MAPCAS and PDA. A discrete stenosis (DS) of pulmonary artery was seen significantly more in patients with RVOT obstructions associated with PDA compared to patients without PDA (67/84 vs. 5/96). Out of the 84 cases with ducti, 53 had stenosis of the pulmonary artery at the site of ductus insertion. Thus presence of PDA was an important factor in the development of DS. The likely cause of pulmonary artery stenosis in TOF with PDA may be the opposing flows through RVOT and PDA producing a watershed effect at the ductus-pulmonary artery junction. Diffuse hypoplasia of pulmonary arteries (DH) was seen more significantly in RVOT obstructions associated with MAPCAs, compared to other patient groups (19/36 vs. 14/87). These small pulmonary arteries had no discrete stenosis and this diffuse hypoplasia might be the result of inadequate blood flow during intrauterine life [Harikrishnan S, Tharakan J, Titus T, Bhat A, Sivasankaran S, Bimal F, Syam Sunder KR, James, KJ. Central pulmonary artery anatomy in right ventricular outflow tract obstructions. Indian Heart Journal 1997;49:624 (Abstract)[18]].

Cineangiography↗

Accurate measures of left ventricular ejection fraction using electron beam tomography: a comparison with radionuclide angiography, and cine angiography.

BACKGROUND: Quantitative determination of ejection fraction is predicated on precise measurement of end-diastolic and end-systolic volumes of the left ventricle. Contrast enhanced electron beam tomography (EBT), with excellent temporal and spatial resolution, has the potential for highly accurate measures of ejection fraction. METHODS: EBT protocol used a short axis scan of the left ventricle (8-12 levels, apex to base) during infusion of iodinated contrast. To assess the accuracy of the measured left ventricular ejection fraction (LVEF), we compared EBT with first-pass radionuclide angiography (RNA) and cine angiography (CINE). RESULTS: A total of 41 patients (26 men and 15 women) underwent all three tests within 1 week. Resting ejection fraction using each modality was assessed in a linear regression model to assess inter-test correlation with the other two modalities. Correlation between CINE and EBT was high (r = 0.90, intercept 4.67, p < 0.001). Similarly, correlation of CINE and RNA (r = 0.87, intercept -5.48, p < 0.001) and between EBT and RNA (r = 0.87, intercept -4.6, p < 0.001) were high. In a subset of those patients with LVEF < or = 40%, correlation was consistently high between EBT and CINE. However, correlations were poor for the comparisons between RNA and CINE (r = 0.40), and between the RNA and EBT (r = 0.47). The mean differences of measured ejection fractions between each of the imaging modality were small. However, there was only modest agreement between each of the comparisons as measured using 95% confidence interval (CI) on Bland-Altman plots. CONCLUSION: These data indicate that the LVEF results are comparable among EBT, RNA, and CINE and can be used interchangeably to assess ventricular function for LVEF > 40%. For LVEF < or = 40%, we demonstrated some disparate results between cine angiography and RNA and between EBT and RNA, indicating that CINE or EBT may provide more accurate assessment.

Cineangiography↗

Quantification of 3-D coronary arterial motion using clinical biplane cineangiograms.

Speculation that the motion of the coronary arteries might be involved in the pathogenesis of coronary atherosclerosis has generated growing interest in the study of this motion. Accordingly, a system has been developed to quantify 3-D coronary arterial motion using clinical biplane cineangiograms. Exploiting the temporal continuity of sequential angiographic images, a template matching technique is designed to track the non-uniform frame-to-frame motion of coronary arteries without assuming that the vessels experience uniform axial strain. The implementation of the system is automated by a coarse-to-fine matching process, thus improving the efficiency and objectivity of motion analysis. The system has been validated and employed to characterize the in vivo motion dynamics of human coronary arteries; illustrative results show that this system is a promising tool for routine clinical and laboratory analysis of coronary arterial motion.

Cineangiography↗