Microcomputer-based pulse stimulator.

Abstract

A low-cost PC-based 2-channel stimulator was designed. This device can generate regular current pulses for many neuroscience experiments. It can also generate irregular pulses for nerve stimulation, thus could possibly avoid the problem of sensitization or habituation in the central nervous system. The stimulation frequency (can be < 0.0005 Hz) and pulse duration (5 microseconds to 65 ms) of this device can be programmed by an interactive user interface. Furthermore, the output current (0-10 mA) can be continuously varied and was optically isolated to minimize stimulus artifact. Moreover, features such as low-power consumption (0.2 mA of a 9 V battery) and high-compliance output (> 120 V) could accommodate the stimulator for widespread applications. A trial of nerve stimulation was illustrated besides the electrical specifications of the stimulator.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F S Jaw, S J Liu, T S Kuo, C Y Wang. 1995. Microcomputer-based pulse stimulator.. https://doi.org/10.1016/0165-0270(95)00076-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Cardiovascular collapse caused by electrocardiographically silent 60-Hz intracardiac leakage current. Implications for electrical safety.

BACKGROUND: The national standard for safe 60-Hz intracardiac leakage current under a single-fault condition is 50 microA. This standard is intended to protect patients from alternating current (AC) at levels below the threshold for sensation, but the minimum unsafe level for AC in closed-chest humans is not known. To determine this value, we studied 40 patients at testing of implantable cardioverter-defibrillators using a programmable source of 60-Hz AC. METHODS AND RESULTS: We applied AC for 5-second test periods in increasing strengths until ventricular fibrillation (VF) was induced or 1 mA was reached. Two current paths were tested: bipolar, between tip and ring electrodes of a right ventricular pacing catheter, and unipolar, from tip to a remote electrode. We observed a characteristic sequence of 3 responses as AC was increased: (1) intermittent ventricular capture with QRS morphology identical to pacing through the electrodes (minimum value, 20 microA); (2) continuous capture at cycle length 282+/-88 ms (minimum value, 32 microA); and (3) VF persisting after AC termination (minimum value, 49 microA). Continuous capture caused loss of pulsatile arterial pressure and cardiovascular collapse (mean arterial pressure, 32+/-8 mm Hg) for the duration of AC with no ECG evidence of AC stimulation. Thus, the clinical picture was that of hypotensive ventricular tachycardia (VT). The continuous-capture threshold was </=50 microA in 9 patients (22%) for bipolar AC and in 5 (12%) for unipolar AC. All patients showed continuous capture over a wide range for both bipolar AC (68+/-18 to 216+/-238 microA) and unipolar AC (84+/-27 to 278+/-226 microA). CONCLUSIONS: Leakage current causes cardiovascular collapse at levels below the VF threshold. Stimulation by silent AC that is neither felt nor visible on the ECG presents as hypotensive VT. In patients with intracardiac electrodes, leakage current less than or equal to the present standard of 50 microA may cause VT or VF. The safety standard for leakage current lasting >/=5 seconds should be </=20 microA. This standard should be based on the continuous-capture threshold.

Electric Stimulation

Evaluation of refractory epilepsy treated with vagus nerve stimulation for up to 5 years.

We assessed the long-term efficacy of vagus nerve stimulation (VNS) in 64 refractory epilepsy patients. After implantation, intermittent stimulation was delivered and seizure frequency and severity were counted. Average treatment time was 20 months. Nineteen of 47 patients with partial seizures, five of nine patients with idiopathic generalized seizures, and five of eight patients with Lennox-Gastaut syndrome had >50% seizure reduction. Side effects were mild. VNS is a safe and effective treatment for refractory epilepsy.

Electric Stimulation