Visualizing tissue compliance with MR imaging.

Abstract

We propose a method for visualizing the mechanical properties of tissue based on the use of periodic mechanical compression in conjunction with phase-contrast MR imaging. A specialized mechanical transducer was used to provide programmable compression pulses to the surface of compliant phantoms. These compression pulses were synchronized to a spin-echo sequence with motion-sensitizing gradients to generate phase information reflecting spin displacement throughout the phantom. This sequence was tested with two agarose gel phantoms. The first was a cylinder containing three parallel layers of varying compliance and the second was composed of a semirigid sphere suspended in a uniform layer of decreased elastic modulus. Images showed complex patterns of motion throughout the phantom, which correlated with expected motion behavior of the phantom structures. This indicates that the biomechanical properties of tissues may be elucidated through the use of motion-sensitized MR imaging and suggests that a form of image contrast relating to tissue elasticity may be feasible.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D B Plewes, I Betty, S N Urchuk, I Soutar. Visualizing tissue compliance with MR imaging.. https://doi.org/10.1002/jmri.1880050620

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A rigorous method for evaluation of the 6D compliance of external fixators.

External fixators are standard devices to stabilize bone fractures and their compliance aims at producing an interfragmentary motion that promotes rapid and successful healing. While evaluation of their axial compliance is a routine test, the quantification and interpretation of their full 6 x 6 compliance matrix is an extensive and delicate task. In this context, the objective of this study was to develop, validate and demonstrate the potential of a rigorous method to quantify their 6 x 6 compliance matrix. An experimental system was developed to apply six independent static forces and moments to an external fixator in the field of view of two infrared cameras quantifying the induced motion. The system was then tested with a calibration structure which compliance could be calculated analytically and numerically. Finally, the system was applied to compare three configurations of a commercial external wrist fixator. The results of the method proved to be reproducible and highly consistent with the linear elasticity theory in the physiological range of small deformations. A rigorous method for evaluation of the 6D compliance becomes therefore available for research in mechanobiology of fracture healing by external fixation.

Compliance↗

Fatigue of packable dental composites.

OBJECTIVE: The purpose of the study was to measure the fatigue properties of four dental resin composites using a dynamic mechanical analysis and to relate the results with viscoelastic properties. METHODS: Dynamic torsional loading was conducted at resonance at 30-50Hz. Specimens were thoroughly cured and tested dry at 21 degrees C. RESULTS: All of the specimens showed a loss of strength following repeated stress, due to material fatigue. The material with the highest shear modulus had the lowest damping and the highest fatigue strength. SIGNIFICANCE: Dental composites exhibit a modest loss of strength due to fatigue. Since mastication involves many cycles of stress during the life of a restoration, fatigue properties should be taken into account in restoration design.

Compliance↗