Search PubMedSearch

SEARCH · Search PubMed

Results for “Compliance”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

22 recordsLinked to original sources

Digital healthcare solutions in preoperative care: A systematic review.

OBJECTIVE: Active participation in preoperative anesthesia preparation is crucial to ensure safe and efficient care. Compliance with preoperative instructions improves clinical outcomes, enhances patient satisfaction and optimizes use of healthcare resources. As digital communication becomes increasingly integrated into healthcare, interactive digital tools such as smartphone applications and Short Message Service (SMS) reminders may offer a valuable means of engaging patients in their own care. In this review, we evaluated the role of digital tools in guiding patients during their preoperative care pathway for anesthesia. METHODS: Following registration (CRD420250655119), we conducted a systematic review of studies evaluating the use of smartphone applications or SMS reminders designed to support preoperative preparation for anesthesia or procedural sedation in adult patients undergoing elective procedures. The primary outcome was compliance with preoperative instructions. Secondary outcomes included rate of late cancellations, patient satisfaction and cost-effectiveness. Studies were eligible if they reported at least one of these outcomes. RESULTS: Ten studies (1 RCT and 9 observational studies), including 11501 participants, were identified. Compliance with preoperative instructions was assessed in 8 studies, most of which reported higher compliance in patients receiving digital interventions across multiple instruction domains, although statistical significance was not consistently observed. Evidence suggested a beneficial effect on reducing late cancellations and improving patient satisfaction. However, results varied across study designs, and data on cost-effectiveness were limited. CONCLUSIONS: Digital tools for preoperative anesthesia guidance were associated with higher compliance and showed potential reduction of late cancellations and increase of patient satisfaction. However, the current evidence is predominantly observational and heterogeneous, limiting the strength of conclusions. PRACTICAL IMPLICATIONS: With healthcare systems under pressure, digital technologies may offer a scalable and patient-centered care solution to support preoperative anesthesia preparation. Nonetheless, further high-quality research is needed to evaluate their long-term clinical, economic and equity implications.

Humans

One in three patients with positional obstructive sleep apnea does not benefit from positional therapy: Insights from a home-based trial.

PURPOSE: Positional obstructive sleep apnea (POSA) is the most common phenotype of obstructive sleep apnea, yet patient selection for positional therapy (PT) remains suboptimal. With this analysis we aimed to clarify how many patients with POSA may not require PT because they do not habitually sleep supine at home, and how many fail vibrotactile PT despite appropriate indication. METHODS: We conducted a retrospective observational study of consecutive adults with POSA evaluated at a tertiary sleep center between 2021 and 2024. All patients underwent a home-based trial with a neck-based vibrotactile positional therapy device (Night Shift™), consisting of monitoring mode followed by therapy mode. Outcomes included the proportion of non-supine sleepers at home, failure rate of vibrotactile PT, device compliance and differences in supine sleep time between diagnostic testing and home monitoring. RESULTS: Of 92 screened patients, 74 met inclusion criteria (mean age 60.3 ± 13.2 years; mean AHI 22.9 ± 13.3 events/h). Fifteen percent (11/74) did not habitually sleep supine at home, indicating no clinical need for PT, and an additional 14.8% (11/74) failed vibrotactile PT. Overall, 30% of patients were either unlikely to benefit from PT or failed therapy. Non-response was frequently associated with psychotropic or sedative medication use and neurological or sleep-related comorbidities. CONCLUSION: A substantial proportion of patients diagnosed with POSA either do not require or fail vibrotactile treatment in real-world conditions. Incorporating a brief home monitoring and therapy trial into routine clinical practice may optimize patient selection, reduce unnecessary costs, and improve personalized management of POSA.

Humans

Do adherence-focused interventions in low back pain have an impact on rehabilitation outcomes? A systematic review with meta-analysis.

BACKGROUND: Low back pain (LBP) is the leading cause of disability worldwide. Exercise-based interventions are effective, but adherence remains suboptimal. This systematic review and meta-analysis evaluated the effectiveness of strategies designed to enhance adherence to exercise-based interventions in individuals with LBP in terms of adherence as well as pain and functionality. METHODS: Randomized controlled trials including adults with non-specific LBP were eligible if they compared exercise-based interventions incorporating adherence-enhancing strategies versus exercise alone or usual care. Primary outcome was adherence; secondary outcomes were pain and functionality. Searches were conducted in PubMed, Embase, Web of Science, Cochrane Library, CINAHL, Scopus, and PEDro up to May 2026. Two reviewers independently screened studies, extracted data, and assessed risk of bias using the Cochrane RoB 2 tool. Random-effects meta-analyses were performed using standardized mean differences. Certainty of evidence was evaluated using the GRADE approach. RESULTS: Fourteen randomized controlled trials including 1233 participants were included. Risk of bias was low in six studies, with the remainder showing some concerns or high risk. For adherence outcomes, evidence showed no clear effect of adherence-enhancing strategies on either device-measured physical activity (SMD = 0.21, 95% CI -0.01 to 0.43; 3 trials, 320 participants; moderate-certainty evidence) or questionnaire-based adherence (SMD = 0.33, 95% CI -0.23 to 0.89; 4 trials, 377 participants; very low-certainty evidence). For pain and functionality, moderate certainty of evidence indicated small improvements favoring intervention groups in the medium term. CONCLUSIONS: Strategies to enhance adherence to exercise in LBP show uncertain effects on adherence but may provide small improvements in clinical outcomes in the medium term. Higher-quality trials are needed to strengthen the evidence base.

Adult

Foot exercise plus education versus brief advice for the treatment of plantar heel pain (FEET Trial): a feasibility randomised controlled trial.

BACKGROUND: Despite foot muscle strengthening being a target of exercise interventions for plantar heel pain (PHP) no study has measured foot muscle outcomes, and existing research is limited by a lack of control (no treatment) comparisons. OBJECTIVES: To determine the feasibility of conducting a randomised controlled trial and investigate the acceptability and credibility of comprehensive progressive foot exercise and education compared to brief advice for PHP. DESIGN: Randomised parallel group feasibility trial. METHOD: People with PHP were randomised (1:1 concealed allocation) to receive either foot exercise plus education or brief advice for twelve weeks. Primary outcomes included willingness to enrol, recruitment rate, adherence, logbook completion, dropout rate, early withdrawal reasons, adverse events, additional treatments sought, and credibility/expectancy. RESULTS: Twenty people with PHP (16 women; age 50 ± 9 years; body mass index = 30.7 ± 4.6 kg/m2) were recruited over 15 weeks (1.3 participants per week). Primary outcomes were willingness to enrol (80%), adherence (physiotherapy sessions attended: foot exercise plus education 85%, brief advice 100%; home exercise program: 62% daily sessions completed, 72% thrice weekly sessions completed), logbook completion (foot exercise plus education 75%, brief advice 90%), dropout rate (15%), and additional treatments sought (69%). There were no intervention-related adverse events, and credibility scores were higher for foot exercise plus education. CONCLUSIONS: This study confirms feasibility and acceptability of a protocol comparing foot exercise plus education with brief advice in individuals with PHP, generating key insights to inform future trial design.

Humans

The effect of nutrition education interventions on dialysis patients' outcomes: a systematic review and meta-analysis.

BACKGROUND: Non-adherence to dietary and fluid restrictions among dialysis patients is associated with adverse clinical outcomes. Quantifying the effectiveness of nutrition education interventions can inform practice and policy. METHODS: We searched MEDLINE, EMBASE, CINAHL, CENTRAL, PsycINFO, Web of Science, and Scopus up to 15 July 2025, supplemented by trial registries and Google Scholar, with an updated search through 8 April 2026. Eligible studies included randomized and non-randomized trials evaluating nutritional education interventions in adult dialysis populations. Risk of bias was assessed using RoB-2 and ROBINS-I, certainty graded using GRADE, and random-effects meta-analyses conducted alongside subgroup, sensitivity, and meta-regression analyses. Publication bias was assessed with Egger and Begg tests and trim-and-fill where applicable. RESULTS: Forty-four studies comprising 4,106 participants were included. Nutrition education significantly improved knowledge (SMD = 1.09; 95% CI: 0.67-1.51) and health-related quality of life (SMD = 1.43; 95% CI: 0.86-2.00; I² = 0%), and reduced serum potassium (SMD = -0.52; 95% CI: -0.91 to -0.14; I² = 92%) and serum phosphate (SMD = -0.35; 95% CI: -0.56 to -0.15; I² = 81%). Results for albumin, creatinine, sodium, calcium, and BUN were inconsistent and non-significant. Most outcomes were rated low or very low certainty by GRADE, reflecting inconsistency, indirectness, and imprecision. Potential publication bias was identified for certain outcomes. CONCLUSIONS: Nutrition education consistently improves knowledge and quality of life and may modestly reduce serum phosphate and potassium in dialysis patients. High-quality registered trials with standardized outcomes and longer follow-up are needed to establish effectiveness and sustainability. PROSPERO REGISTRATION: CRD420251119567.

Humans

Intervention components, training dose, and adherence in exercise-based prevention of hamstring strain injury in football: a systematic review and meta-analysis.

OBJECTIVE: To quantify associations between exercise-based prevention programmes and hamstring strain injury (HSI) risk in football participants, and whether training dose and adherence modify effects. METHODS: Six databases were searched to 1 October 2025. Randomised and cluster-randomised trials comparing HSI prevention programmes with usual practice or warm-up in football participants were included. Random-effects meta-analysis pooled risk ratios (RRs); subgroup analyses and meta-regression assessed effect modification. RESULTS: Fifteen trials (n = 7,465) were analysed. Programmes reduced HSI risk (RR = 0.51, 95% CI 0.36-0.71), with I&#xb2;=57% and a prediction interval crossing the null (0.18-1.40). Based on a control event rate of 7.8%, absolute risk reduction was 3.8% (38 fewer HSIs per 1000 participants; 95% CI 23-50 fewer). Effects were stronger for shorter interventions (1-6 months; RR = 0.43) than longer interventions (7-10 months; RR = 0.77; P for interaction=0.04), and for elite/semi-professional players (RR = 0.38) than amateur players (RR = 0.77; P for interaction = 0.02). Training frequency and weekly volume did not modify effects, whereas adherence did. High adherence (&#x2265;75%) was associated with lower HSI risk (RR = 0.36, 95% CI 0.28-0.48), whereas low adherence (<75%) showed no clear benefit (RR = 0.92, 95% CI 0.68-1.23; P for interaction <0.00001). Each 10% increase in adherence corresponded to an RR multiplier of 0.83 (approximately 17% lower RR). Certainty of evidence was low. CONCLUSION: Exercise-based programmes reduce HSI risk in football when implementation supports sustained adherence. Effects may be stronger in shorter interventions and elite populations, but evidence remains insufficient to differentiate programme types or components.

Humans

A prospective crossover study comparing ICCS-recommended and Palmer-adjusted filling rates in children with spina bifida.

OBJECTIVE: This study aimed to investigate whether the maximal cystometric capacity (MCC) in children with spina bifida (SB) is indeed lower, as predicted by the Palmer formula, and to evaluate the impact of different bladder filling rates on urodynamic parameters. MATERIALS AND METHODS: This prospective, randomized, two-sequence crossover-controlled study included 70 children aged 3-18 years with spina bifida under regular follow-up. In Group 1, the first two bladder fillings were performed at the ICCS-recommended rate, and the third at 75% of that rate (Palmer formula). In Group 2, the sequence was reversed. Urodynamic parameters, including maximal cystometric capacity (MCC), bladder compliance, detrusor activity, filling pressures, and detrusor leak point pressure (DLPP), were analyzed across fillings. RESULTS: Cystometric bladder capacity was lower during fillings performed at the Palmer-adjusted rate compared with those at the ICCS-recommended rate. The proportion of reduced compliance significantly decreased in Group 1 (p = 0.046) but remained unchanged in Group 2. A significant positive correlation was observed between expected bladder capacity (EBC) and measured MCC in both groups (&#x3c1; &#x2248; 0.5-0.6). The highest correlation and agreement were found in Group 1 during the third filling at the Palmer rate (ICC = 0.606). No significant intra- or intergroup differences were observed in detrusor pressure, end-filling pressure, DLPP, or overactive bladder prevalence. CONCLUSION: Bladder filling rate was associated with differences in both cystometric capacity and bladder compliance in children with spina bifida. Fillings performed according to the Palmer formula (approximately 75% of the ICCS-recommended rate) were associated with capacities that more closely approximated age-expected values and with modest differences in bladder compliance. Conversely, faster filling rates did not produce similar benefits. These findings suggest that slower filling strategies may improve measurement consistency and agreement with expected bladder capacity estimates. However, the magnitude and direct clinical impact of these differences should be interpreted cautiously, particularly in light of the potential influence of sequence-related effects.

Humans

Exercise Snacks Are Feasible to Perform in the Real World and Improve Physical Capacity for Adults Living With Non-Insulin Treated Type 2 Diabetes: A Randomised Trial.

AIMS: To investigate the feasibility and preliminary efficacy of a 12-week remotely-delivered exercise snacks (ES) intervention in adults with type 2 diabetes. MATERIAL AND METHODS: Insufficiently active adults with type 2 diabetes (N&#x2009;=&#x2009;69; 46 females; mean age&#x2009;&#xb1;&#x2009;SD: 58&#x2009;&#xb1;&#x2009;11&#x2009;years) were randomised to an ES or mobility/stretching comparator group (CON), which involved 4&#x2009;&#xd7;&#x2009;1-min bouts of either vigorous or low intensity exercise, respectively, on &#x2265;&#x2009;5&#x2009;days/week. The primary outcome was feasibility based on adherence. Secondary outcomes included exercise enjoyment (1-7 scale), rating of perceived exertion (RPE; 0-10 scale), heart rate (HR), haemoglobin A1c (HbA1c), blood biomarkers of cardiometabolic health, 30-s sit-to-stand capacity, grip strength, estimated maximal oxygen uptake, and anthropometrics. RESULTS: Weekly adherence (estimated marginal mean [95% confidence interval]: 18 bouts [16-21] for both groups; p&#x2009;=&#x2009;0.99) and total enjoyment (ES: 4.5 [4.1-4.8] vs. CON: 4.3 [4.0-4.7]; p&#x2009;=&#x2009;0.64) were high and not different between groups. Despite higher RPE (5.7 [5.4-6.1]) and peak HR (73 [70-77] % of age-predicted HR maximum) in ES versus CON (2.0 [1.7-2.4] and 61 [58-64] % of age-predicted HR maximum, respectively) (all p&#x2009;<&#x2009;0.001), there were no between-group differences in the change in any secondary outcome (all p&#x2009;>&#x2009;0.05) except for greater sit-to-stand capacity in ES after training (between-group effect estimate [95% confidence interval]: 1.9 repetitions [0.3-3.4]; p&#x2009;=&#x2009;0.02). CONCLUSIONS: Exercise snacks were feasible to perform in the real world and improved sit-to-stand capacity to a greater extent than CON in adults living with type 2 diabetes. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT06407245.

Aged

Sensor-based measures of knee brace adherence have low agreement with self-report methods: A multi-measure study among knee osteoarthritis patients.

OBJECTIVE: To explore agreement between self-report and objectively measured adherence to brace wearing by patients with knee osteoarthritis. METHOD: A single-arm observational analysis nested within the PROP OA randomised controlled trial (ISRCTN28555470). Of 237 adults with symptomatic knee osteoarthritis randomised to brace treatment, 60 were included in this sub-study investigating three different methods of assessing knee brace wear time over 26 weeks: 1. Self-report questionnaires (SRQ) at 12 weeks and 26 weeks; 2. Short message service (SMS) questions (days worn in past week, typical hours per day when worn) administered from week 1 to week 24; 3. A skin temperature sensor embedded in the brace, sampling every 10&#x202f;min for 26 weeks. The presence and reason for the sensor were concealed from participants. The estimated proportion of participants meeting "minimum brace use", defined a priori as &#x2265;1&#x202f;h on &#x2265;2 days in past week, was described for each measurement method, overall and by brace type (unloader, neutral). For temperature sensor measurements, time spent above 24&#xb0;C and time spent above 25&#xb0;C were used. Agreement between the measures was summarised by percentage agreement and kappa (&#x138;). RESULTS: The estimated proportions of participants meeting "minimum brace use" at 12 weeks were 83% (SRQ), 83% (SMS), 60% and 58% (temperature sensor, 24&#xb0;C and 25&#xb0;C thresholds, respectively). At 26 weeks, the corresponding estimates reduced to 72%, 71% (SMS at 24 weeks), 43% and 37%. Sensor data suggested the sharpest decline in brace use occurred within the first 12 weeks. Agreement between self-report measures was higher than between self-report measures and sensor (SRQ vs SMS at 12 weeks: 92% agreement, &#x138;=0.67 (95%CI: 0.34, 1.00); SRQ vs Sensor at 12 weeks: 74%, 0.35 (0.10, 0.60); SMS vs Sens at 12 weeks: 76%, 0.36 (0.05, 0.66). Agreement between all measurement methods reduced at 26 weeks. CONCLUSIONS: This novel use of a temperature sensor to monitor brace adherence in knee osteoarthritis indicates that self-report adherence substantially overestimates knee brace wearing time, with implications for clinical trials and practice.

Humans

Latent profile analysis of pregnant exercise adherence and the relationship with demographic and socio-psychological factors: a multicentre cross-sectional study.

BACKGROUND: Pregnancy physical activity (PA) and exercise benefits both mothers and babies, but requires sustained adherence. Many pregnant women fail to meet recommended levels. The reasons for low adherence comprised fluctuating physiological and environmental factors. This study aims to identify discrete profiles of pregnant women based on exercise adherence and to examine differences in demographic and socio-psychological factors across these profiles. METHODS: A survey was conducted among 1,255 pregnant women in three hospitals in Shenzhen, Dongguan, and Shunde, China, using the Exercise Adherence Rating Scale (EARS), the Pregnancy Exercise Self-Efficacy Scale (P-ESES), and the Pregnancy Physical Activity Social Support Scale (P-PASSS). In the analysis, EARS items were scored higher, indicating a healthier state (e.g., sufficient time and energy). Latent profile analysis (LPA) was employed to classify adherence profiles, and multinomial logistic regression was used to examine differences in demographic, self-efficacy, and social support across four groups. RESULTS: Four profiles of exercise adherence were identified: (1) Profile 1 (16.97%), characterized by deficits in time and energy, (2) Profile 2 (15.22%), a group with sufficient time resources but the lowest self-efficacy, (3) Profile 3 (43.98%), characterized by high adherence despite moderate barriers, and (4) Profile 4 (23.83%), a group with optimal exercise adherence, confidence, and resources. Women with higher P-ESES (OR: 1.14-1.38) and P-PASSS (OR: 1.04-1.06) scores were more likely to be in Profiles 3 and 4. Additionally, women's partners who never or occasionally exercise were significantly more likely to be categorized into Profile 1 (OR = 0.18 for Profile 4 vs. Profile 1). Furthermore, the first trimester emerged as a significant risk period for lower exercise adherence, whereas overweight/obesity was independently associated with higher odds of membership in Profile 4. CONCLUSION: The study identified four distinct profiles of exercise adherence among pregnant women. 32.19% of participants were in the two lower exercise-adherence groups. Pregnant women in Profile 1 were characterized by challenges related to a lack of time and knowledge. Participants in Profile 2 showed the lowest exercise self-efficacy and social support among the four profiles. Furthermore, women in early pregnancy were more likely to have lower adherence profiles. Hence, targeted interventions addressing these specific groups are warranted to improve exercise adherence during pregnancy.

Humans

How AI-supported intelligent systems support infection prevention and control training in healthcare: A systematic review of educational functions and outcomes.

AIMS: Artificial intelligence (AI)-supported intelligent systems have been increasingly incorporated into infection prevention and control (IPC) education and training, primarily to support the monitoring of observable behaviors and the provision of feedback. However, existing evidence has focused largely on short-term compliance outcomes, with limited synthesis of the educational role of AI-supported intelligent systems in supporting sustained IPC competence. This systematic review examined how AI-supported intelligent systems have been designed and used to support IPC education and training, with a focus on system characteristics, educational functions, and reported outcomes. DESIGN: A systematic literature search was conducted across the PubMed/MEDLINE, Embase, Cochrane, and CINAHL databases. DATA SOURCES: A total of 18 studies met the inclusion criteria. Findings were qualitatively synthesized according to system design characteristics, educational functions, and outcome domains. REVIEW METHODS: Methodological quality was appraised using the Mixed Methods Appraisal Tool. RESULTS: Most AI-supported intelligent systems focused on hand hygiene and relied on fully automated monitoring systems to capture behaviors and provide performance feedback. Educational functions were predominantly limited to performance assessment, automated feedback, and reminders. Outcomes were mainly measured using compliance or performance metrics, whereas sustained behavioral change and decision quality were rarely assessed. CONCLUSIONS: AI-supported intelligent systems have been used primarily to reinforce short-term IPC performance and compliance. However, their current applications for supporting sustained competence over time remain limited. The findings of this review suggest that AI-supported intelligent systems may serve as maintenance-oriented educational support by extending learning beyond initial instruction through repeated practice and feedback. Future research should prioritize outcome measures that capture the durability of performance and decision-making processes to better align AI-supported intelligent systems used in IPC education and training with the educational demands of clinical practice.

Humans

Does future-oriented imagery rescripting increase willingness to carry out a social anxiety-related behavioral experiment? An extended replication.

BACKGROUND AND OBJECTIVES: Mental images of threat are common in social anxiety disorder and could impede exposure to fear-relevant situations. Landkroon et al. (2022) found that imagery rescripting of anticipated future threat, compared to no-task, increases willingness of non-clinical individuals to conduct a social anxiety-related behavioral experiment. The aim of this two-day preregistered extended replication study was to examine whether the effects persist beyond the intervention session by scheduling the behavioral experiment 1-7 days after the intervention. METHODS: On Day 1, 60 pre-screened participants were asked to design a behavioral experiment to test an idiosyncratic negative belief about a feared social situation. They were then randomly assigned to imagery rescripting (focused on their worst feared outcome of the behavioral experiment) or no-task. Participants' willingness to do the behavioral experiment and their threat beliefs was measured. On Day 2, they were asked to carry out the behavioral experiment. RESULTS: The imagery rescripting group, compared to the control group, did not show increased willingness or compliance to do the behavioral experiment on Day 1 or 2. Furthermore, the imagery rescripting did not lead to greater reductions in threat beliefs on either day. LIMITATIONS: The quality of the imagery rescripting intervention was not assessed, and given the brief nature of the intervention, any effects may have dissipated before participants decided whether to carry out the behavioral experiment. CONCLUSIONS: There was no evidence that imagery rescripting leads to changes in willingness or compliance to do a fear-relevant behavioral experiment. More research is needed to examine interventions that can enhance exposure in socially anxious people.

Humans

Self-healing materials for food packaging: Design principles, activation mechanisms and implications for food safety.

Self-healing materials (SHMs), originally developed to restore mechanical integrity, have recently attracted growing interest in food packaging. By autonomously repairing physical damage, SHMs help preserve packaging integrity, barrier performance, food safety, and shelf-life during storage and transportation. This review summarizes recent advances in the design principles, activation mechanisms, material systems and food packaging applications of SHMs. Key healing strategies, including microencapsulation, dynamic covalent bond exchange, reversible non-covalent interactions and responsiveness to external stimuli such as temperature, pH, and humidity, are discussed. Representative material systems, including biopolymer-based films, hydrogels, nanocomposites, and stimuli-responsive polymers are evaluated with respect to their relevance to packaging animal-derived foods, fruits, and vegetables. Performance evaluation methods, sustainability implications, and food-contact safety concerns are addressed. Despite promising healing efficiency and mechanical resilience, challenges remain regarding production cost, food-grade safety, migration risks, trigger compatibility and stability under fluctuating environmental conditions. Future research should focus on scalable manufacturing, standardized evaluation protocols, repeated damage-healing safety assessment, regulatory compliance, and integration with intelligent packaging technologies.

Food Packaging

Systematic modular engineering of genome-integrated Escherichia coli MG1655 for high-level 2'-fucosyllactose production.

2'-Fucosyllactose (2'-FL), the most abundant human milk oligosaccharide (HMO), has attracted considerable interest for its prebiotic and immunomodulatory functions, with broad applications in infant nutrition. In this study, we report the development of a high-yield, genome-integrated 2'-FL-producing strain based on Escherichia coli MG1655 through systematic modular optimization. Starting from a single-copy BKHT strain (MGC06), we first optimized the copy number of the &#x3b1;-1,2-fucosyltransferase (&#x3b1;-1,2-FT) gene BKHT. Subsequently, the GDP-L-fucose supply was enhanced through coordinated genomic integration of the gene clusters cpsG-cpsB and gmd-fcl, while the multidrug efflux transporter gene mdfA was integrated to improve product export and strain robustness. BKHT copy number was then re-evaluated in the optimized background, with four copies yielding the highest production. The final engineered strain, harboring all genetic modifications stably integrated into the chromosome, produced 17.18 g/L 2'-FL in shake-flask culture. In fed-batch fermentation using a 5-L bioreactor, this strain achieved a titer of 154.12 g/L after 60&#x202f;h, with a productivity of 2.57 g/L/h. Notably, throughout the entire fermentation process, no antibiotics or inducers were supplemented, underscoring the genetic stability and regulatory compliance of this plasmid-free system. To our knowledge, this represents the highest 2'-FL titer reported to date, positioning our engineered strain as a promising candidate for commercial 2'-FL production.

Escherichia coli

Nondominant Hand Training in Laparoscopy for Surgical Interns: Feasibility and Impact.

OBJECTIVE: Laparoscopy requires bimanual proficiency, yet early trainees demonstrate underdeveloped nondominant hand (NDH) performance. Although deliberate practice of NDH skill contributes to overall performance, NDH training is rarely incorporated into residency simulation curricula and has not been formally evaluated in surgical trainees. We assessed feasibility and impact of integrating structured NDH training with established laparoscopic curriculum for surgery interns. DESIGN: Prospective, single-institution randomized pilot study. Interns were assigned the standard 4-week curriculum of laparoscopic dominant hand and bimanual tasks (Control) or completed assigned NDH tasks in addition to the standard curriculum (Intervention). Feasibility was determined by assigned task completion, daily standard and NDH-specific self-reported practice time, and improvement in bimanual task performance. Performance was video recorded weekly and assessed by blinded evaluators using MISTELS and GOALS scoring. Cognitive workload during laparoscopic tasks was measured via NASA-TLX. Exploratory analyses were conducted within a Bayesian framework. SETTING: A single academic institution with a surgical simulation training program. PARTICIPANTS: General surgery interns on their 4-week simulation rotation. RESULTS: Eleven general surgery interns (6 intervention, 5 controls; all right-hand dominant) completed the study with 100% task completion and practice log compliance. Both groups improved in bimanual performance and perceived cognitive load. Reduction in cognitive workload during bimanual task performance was greater in the NDH group. Time spent on NDH practice over 4 weeks was associated with improved bimanual performance, independent of time spent on standard curriculum tasks. CONCLUSIONS: Structured NDH training is feasible to implement within an existing curriculum and reduces perceived cognitive workload during bimanual laparoscopic tasks. NDH practice demonstrates a beneficial dose-response relationship with performance, supporting its integration into early laparoscopic training.

Laparoscopy

Unravelling bioanalytical innovations, degradation processes, and impurity landscapes of VEGFR inhibitors.

From pre-formulation studies to clinical trials, VEGFR-targeted small-molecule tyrosine kinase inhibitors (TKIs) require rigorous analytical standards. Bioanalysis, stability-indicating studies, and impurity profiling are used to examine chromatographic advances for VEGFR-targeted TKIs like sunitinib, pazopanib, axitinib, sorafenib, cabozantinib, vandetanib, apatinib, lenvatinib, nintedanib, and regorafenib. An LC-MS/MS and UPLC-MS/MS routinely show sub ng/mL performance, as shown by LLOQs (0.2&#xa0;ng/mL) for sunitinib and axitinib, 1&#xa0;ng/mL for pazopanib, 5-7&#xa0;ng/mL for sorafenib, 0.5-1.5&#xa0;ng/mL for regorafenib metabolic products, and 0.1-0.5&#xa0;ng/mL for lenvatinib. These approaches are used for pharmacokinetics and therapeutic drug monitoring due to their good correlation coefficient of 0.1-10,000&#xa0;ng/mL, accuracy of 95%-108%, and precision of 15% RSD. UPLC-QTOF-MS/MS distinguishes degradants and metabolites during forced degradation studies, enabling structural elucidation following ICH M7 risk evaluation protocol. HPTLC/MLC offers fast, sensitive screenings, while RP-HPLC/DAD or HPLC-UV offer reliable, cost-effective routine quality-control solutions with LOD/LOQ in the &#x3bc;g/mL range and linearity of 10-240&#xa0;&#x3bc;g/mL. This review lists the structures and CAS numbers of ten VEGFR-2 TKI degradants and metabolites, as well as pharmacopeial impurities in SMILES forms. It will be useful for future method development and regulatory applications. To ensure VEGFR-targeted TKI quality, safety, and therapeutic efficacy, LC-MS/MS for trace quantification and HRMS for structure elucidation provide a robust, future-oriented framework. To improve VEGFR-targeted TKI quality, safety, and regulatory compliance, analytical development should focus on HRMS-based impurity characterization, AI-assisted degradation prediction, green chromatography, and harmonized bioanalytical validation.

Humans

Associations between smart infusion pump-electronic health record interoperability and healthcare outcomes: A systematic review.

OBJECTIVE: This study synthesized available evidence on the associations between smart infusion pump-electronic health record (EHR) interoperability and healthcare outcomes. METHODS: A systematic review of PubMed, CINAHL, Embase, and Scopus databases identified 901 records, which were imported into Rayyan&#xae; for duplicate removal, independent screening by three reviewers, and resolution of discrepancies. Eligible studies were peer-reviewed, data-driven, and reported associations between smart infusion pump-EHR interoperability and healthcare outcomes. Studies focused solely on technical validation or interoperability prototypes were excluded. A backward citation search identified additional studies. Two reviewers independently extracted and cross-validated study characteristics using standardized templates. Methodological quality was assessed with the Joanna Briggs Institute Critical Appraisal Tools. RESULTS: Twenty records of 14 full-text studies and 6 conference proceedings were included. Most records reported positive associations between smart infusion pump-EHR interoperability and outcomes related to safety (e.g., medication administration errors, safety-reported events, pump alerts, and compliance with interoperability and drug library), operational efficiency (e.g., programming and documentation time and technical issues), financial performance (e.g., charges captured, and cost avoided), and user experience domains. Most studies used observational designs, reflecting real-world interoperability implementations, where controlling confounding factors is challenging. Limited reporting of baseline characteristics, pump type, and sample sizes limited comparability across studies. CONCLUSIONS: Smart infusion pump-EHR interoperability was associated with improvements in patient safety, efficiency, charge capture, and user experience, with variable findings across studies. Future research should use rigorous methodologies and standardized measures, examine relationships across outcome domains, assess limitations of pump-EHR interoperability, and evaluate underexplored outcomes, including team communication, cognitive workload, and AI-enabled pumps. IMPLICATIONS FOR CLINICAL PRACTICE: Interoperability should be viewed as a component of a broader sociotechnical system, in which technology, user, workflow, clinical content, and organizational practices collectively determine overall effectiveness.

Humans

Repeated low-level red-light therapy for improving asthenopic symptoms and accommodation in presbyopia.

BACKGROUND: To assess the short-term effectiveness of repeated low-level red light (RLRL) therapy in relieving asthenopia and enhancing accommodation in presbyopia. METHODS: This randomized, parallel-group, double-masked clinical trial enrolled adults with presbyopia and self-reported asthenopia. Participants were allocated using computer-generated randomization and randomly assigned at a 1:1 ratio to RLRL or sham groups. Blinding included participants, examiners, assessors, and statisticians. The primary outcome was the change from baseline in the Computer Vision Syndrome Questionnaire (CVS-Q) score at day 31. Secondary outcomes were the change in accommodative amplitude (AA), Near Activity Visual Questionnaire (NAVQ) score, habitual near visual acuity, near-addition power, accommodative facility, positive and negative relative accommodation, binocular cross-cylinder response, and accommodative convergence-to-accommodation ratio. Continuous outcomes were analyzed using linear mixed-effects models. RESULTS: Sixty-four of 66 randomized participants (aged 41-62&#x2009;years) completed the 1-month trial. At day 31, RLRL showed greater improvement than sham in CVS-Q score (adjusted mean difference, -1.75 points; 95% CI, -3.10 to -0.39), binocular AA (1.09 D; 95% CI, 0.37 to 1.82), and NAVQ score (-8.07 points; 95% CI, -14.17 to -1.97). The effect on AA was most pronounced in a subgroup of eyes with baseline amplitude >2.0&#x2009;D (adjusted mean difference 1.33&#x2009;D; 95% CI 0.32-2.34). Other measures did not differ between groups at each visit. No treatment-related adverse events were reported. Adherence was similar between groups (mean compliance: 98.2% vs 97.5%). CONCLUSIONS: Short-term treatment with RLRL significantly reduced asthenopic symptoms and improved accommodative amplitude in individuals with presbyopia.Trial registration: NCT06745661 (registered December 8, 2024).

Humans