Search PubMed⌕ Search

PubMed · 8740806

Computerized electro-nystagmography.

Abstract

A computerized electro-nystagmography (ENG) system was developed on the basis of a new idea for the performance of ENG. In this system, all the functions of conventional ENG was performed by a personal computer (PC) except for the initial setting of an analog amplifier. The eye movement signals from the ENG amplifier were displayed on the graphic screen and recorded on a magnetic or magneto-optical disc. By using a special graphic screen, eye movements, even fine nystagmus, can be more clearly observed than they can on the PC's conventional graphic screen. Examiners can select the most suitable display condition according to the specific purpose(s) of the ENG examination. As a laser printer prints the recorded eye movements simultaneously with data sampling, we can observe eye movements in the same manner as on the recorded paper of a conventional ENG. Moreover, this system has a very powerful function for the analysis of such nystagmus responses as caloric test, VOR test and optokinetic nystagmus and it can be gotten at a lower cost than conventional ENG. These technical and economical features indicate that the computerized ENG system is a very useful and convenient device for observing, recording and analyzing ENG examinations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y Watanabe, S Takeda. 1996. Computerized electro-nystagmography.. https://pubmed.ncbi.nlm.nih.gov/8740806/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of vibration on auditory organ systems in low-birth weight infants treated with high-frequency oscillatory ventilation: 5 year outcome.

BACKGROUND: To determine the effects of vibration exposure caused by high-frequency oscillatory ventilation (HFOV) on the auditory organ systems in low-birth weight (LBW) infants. METHODS: Between 1989 and 1990, 30 LBW infants who received assisted ventilation with HFOV (n = 14) or conventional mechanical ventilation (CMV; n = 16) in the level III neonatal intensive care unit at Tokyo Metropolitan Ohtsuka Hospital were enrolled in this study. The effects of vibration exposure on the auditory system structures were investigated with auditory brainstem responses (ABR) at 37-41 weeks of postconceptional age and at 6, 12, 18 and 24 months of age until they passed and follow-up studies were performed at least until 5 years of age. RESULTS: All infants enrolled in the study survived at discharge and one (7.1%) infant in the HFOV group and two (12.5%) in the CMV group failed the initial ABR test, but there were no significant differences between the two groups. Auditory brainstem response abnormalities were still observed in one infant in the HFOV group at 6 months of age, but this child died at 9 months of age because of meningitis. In contrast, in the CMV group, one patient passed the ABR test at 6 months of age, but another remained abnormal at 5 years of age. One of three infants with ABR abnormalities at 6 months of age had neurologic sequelae at 5 years of age and one of 28 infants who passed the initial ABR test was detected with cerebral palsy. No patients with hearing loss were clinically detected at 5 years of age. CONCLUSIONS: The results of the serial ABR examinations and the 5 year follow-up studies suggest that vibration exposure caused by HFOV may not increase the adverse effects on the auditory system in LBW infants.

Audiometry, Evoked Response↗

Cochlear implants in five cases of auditory neuropathy: postoperative findings and progress.

OBJECTIVES: To review our experiences with some of the preoperative and postoperative findings in five children who were diagnosed with auditory neuropathy and were provided with cochlear implants. We describe changes in auditory function, which enabled these children to have significant improvement in their hearing and communication skills. STUDY DESIGN: Pre- and postoperatively, these children received complete medical examinations at Mayo Clinic, including related consultations in audiology, pediatrics, neurology, medical genetics, otolaryngology, psychology, speech pathology, and radiology. METHODS: These children typically had additional medical and audiological examinations at more than one medical center. The hearing assessments of these children included appropriate behavioral audiometric techniques, objective measures of middle ear function, acoustic reflex studies, transient (TOAE) or distortion product (DPOAE) otoacoustic emissions, auditory brainstem responses (ABR), and, in some cases, transtympanic electrocochleography (ECoG). After placement of the internal cochlear implant devices (Nucleus CI24), intraoperatively we measured electrode impedances, visually detected electrical stapedius reflexes (VESR) and neural response telemetry (NRT). These intraoperative objective measures were used to help program the speech processor for each child. Postoperatively, each child has had regular follow-up to assure complete healing of the surgical incision, to assess their general medical conditions, and for speech processor programming. Their hearing and communication skills have been assessed on a regular basis. Postoperatively, we have also repeated electrode impedance measurements, NRT measurements, otoacoustic emissions, and electrical auditory brainstem responses (EABR). We now have 1 year or more follow-up information on the five children. RESULTS: The five children implanted at Mayo Clinic Rochester have not had any postoperative medical or cochlear implant device complications. All of the children have shown significant improvements in their sound detection, speech perception abilities and communication skills. All of the children have shown evidence of good NRT results. All but case D (who was not tested) showed evidence of good postoperative EABR results. Otoacoustic emissions typically remained in the non-operated ear but, as expected, they are now absent in the operated ear. CONCLUSION: Our experiences with cochlear implantation for children diagnosed with auditory neuropathy have been very positive. The five children we have implanted have not had any complications postoperatively, and each child has shown improved listening and communication skills that have enabled each child to take advantage of different communication and educational options.

Audiometry, Evoked Response↗

Safety and patient experience with transtympanic electrocochleography.

OBJECTIVES/HYPOTHESIS: Transtympanic electrocochleography (t-ECOG) is a sensitive diagnostic instrument used for Meniere's disease. It is sensitive by virtue of the recording electrode's position on the promontory of the cochlea where the signals are generated. There is concern about the invasive nature of t-ECOG in comparison to extratympanic recording techniques. The purpose of this study was to examine the safety issues, complications, and patient experience with t-ECOG. STUDY DESIGN: Observational study utilizing retrospective chart review and patient survey. METHODS: The medical records of 205 patients who underwent t-ECOG were reviewed for complications. Complications included persistent tympanic membrane perforation, hearing loss, otitis media, otitis externa, ear canal injury, hemotympanum, and pain. An additional 36 patients undergoing t-ECOG were surveyed on subjective measures such as pain during topical anesthesia of the tympanic membrane, during transtympanic placement of the needle electrode, and during the test procedure and overall experience with t-ECOG. RESULTS: There was one case of a nonhealed, persistent perforation in the setting of acute otitis media directly as a result of t-ECOG. Two patients developed otitis media, and three patients had ear pain for up to 5 days. All 36 patients felt the procedure to be tolerable with minimal discomfort. CONCLUSIONS: Transtympanic electrocochleography may be performed with good patient acceptance and infrequent complications.

Audiometry, Evoked Response↗