Search PubMed⌕ Search

PubMed · 8596873

Echo-planar MR imaging.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E Kanal. 1996. Echo-planar MR imaging.. https://doi.org/10.1148/radiology.198.2.8596873

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Fast spin echo and fast gradient echo MRI with low acoustic noise.

It has been shown previously that a significant reduction of the acoustic noise in standard, slow magnetic resonance imaging (MRI) sequences is achieved when the gradient pulses have long sinusoidal ramps. An improvement of this method is now presented for fast gradient echo (FLASH) and fast spin echo (RARE) sequences. The new strategy consists of using a sinusoidal readout pulse with no plateau and extending the phase encoding pulses to the entire readout period. The distribution of k-space samples is no longer equidistant, and images have to be reconstructed with gridding. A reduction of the acoustic noise by 20-40 dBA was obtained with respect to standard sequences installed by the scanner manufacturer, which is 10-20 dBA better than that with the previously proposed method of sinusoidal ramps. J. Magn. Reson. Imaging 2001;13:960-966.

Echo-Planar Imaging↗

Symmetric echo acquisition for absolute-value display in solid-state NMR imaging.

A method of solid-state NMR imaging that permits echo Fourier transformation (FT) has been devised using a magic echo train. The echo FT imaging can be implemented simply by modifying the gradient pulse sequence in the previous magic echo imaging (TREV-16TS) so that the one-dimensional k-space trajectory follows the sampling points which are symmetric about the k origin. The implemented ability of echo FT improves the performance of the magic echo imaging: the sensitivity gained by radical2, the phase correction is made unnecessary, and the digital resolution is doubled. One- and two-dimensional imaging experiments have been conducted on some solid samples, confirming the improved performance and revealing a TREV-16TS adjustment parameter that is critical for the successful echo FT imaging.

Echo-Planar Imaging↗

In vivo 31P echo-planar spectroscopic imaging of human calf muscle.

Localized phosphorus-31 NMR spectra of human calf muscle in vivo were obtained by means of echo-planar spectroscopic imaging (EPSI) with a 1.5-T whole-body scanner. The technique permits the measurement of two-dimensional 31P SI data at a minimum acquisition time of 2.4 s (8x8 voxels, TR=300 ms). With 9.4 min measurement time (TR=1100 ms, 64 averages) and 25x25x40 mm spatial resolution in vivo the 31P NMR signal-to-noise ratio (S/N) of the phosphocreatine (PCr) resonance was about 45; the multiplets of nucleoside 5'-triphosphates were resolved. Spectral quality permits quantitative assessment of the PCr signal in a measurement time that is shorter by a factor of 2 or more than the minimum measurement time feasible with chemical-shift imaging. In a functional EPSI study with a time resolution of 20.5 s on the calf muscle of volunteers, spectra showed a 40% decrease of the PCr signal intensity (at rest: S/N congruent with12) upon exertion of the muscle.

Echo-Planar Imaging↗