A microchip glucose sensor.

Abstract

A major problem in development of a glucose sensor for use in an implantable artificial pancreas is the lack of reproducibility in signals from sensor to sensor. Each glucose sensor fabricated with currently used methods has a unique response to varying levels of glucose concentration and thus needs to be individually calibrated before use. We have adapted microchip manufacturing techniques for the fabrication of electrochemically based glucose sensors with standardized and reproducible function. Scanning electron microscopic study of the resulting electrode surfaces shows them to be smooth and featureless at all levels of magnification. X-ray diffraction analysis of the electrodes indicates preferential exposure of the [1,1,1] crystal interface. Cyclic voltammetry evaluation of initial sensor response to varying glucose concentrations shows excellent sensor to sensor reproducibility for all sensors made with the same underlayment. Sensors made with titanium underlayment appear to be more differentiated and thus more sensitive to variations in glucose concentration than are sensors with chromium underlayment. Although the initial response of microchip glucose sensors appears to be standardized and reproducible, additional development of an appropriate electrical insulation material is required before long-term study of signal stability is feasible.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J F Patzer, S J Yao, W Xu, T L Day, S K Wolfson, C C Liu. A microchip glucose sensor.. https://doi.org/10.1097/00002480-199507000-00041

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Lymphocyte fractionation using immunomagnetic colloid and a dipole magnet flow cell sorter.

The relationship between cell function and surface marker expression is a subject of active investigation in biology and medicine. These investigations require separating cells of a homogeneous subset into multiple fractions of varying marker expression. We have developed a novel cell sorter, the dipole magnet flow sorter (DMFS), which separates selected T lymphocyte subpopulations, targeted by immunomagnetic colloid, into multiple fractions according to cell surface marker expression, as determined by flow cytometry. A narrow stream of cells is introduced into a sheath of carrier fluid in a rectangular channel while subjected to a perpendicular magnetic force. The special design of the pole pieces ensures a constant magnetic force acting on the magnetically labeled cells in the separation area. Cells are spread across the flow in relation to their magnetophoretic mobility. Separation is achieved by control of the positions of the effluent stream boundaries, which separate fluid volumes with cells of different magnetophoretic mobility. CD4 and CD8 T lymphocytes labeled with primary antibody-fluorescein isothiocyanate (FITC) conjugate and anti-FITC-magnetic colloid are the chosen cell systems. Flow cytometry analysis shows that, for CD4 cells, a three-fold increase in total marker number per cell is observed when comparing the highest to the lowest fluorescence fractions. Similarly, a four-fold increase in total marker number is observed for CD8 cells. We also observed the separation of two dissimilar cell types that differed in expression of the CD4 marker, monocytes and T helper lymphocytes. We believe that this type of separation is applicable to any cells in suspension for which a suitable antibody exists and, due to the comparatively gentle nature of the process, is particularly suitable for the sorting of fragile cells.

Biomedical Engineering