Search PubMed⌕ Search

PubMed · 8497296

Cochlear implants.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D A Ebert, J Vanderbosch, F M Levin. 1993-06-17. Cochlear implants.. https://pubmed.ncbi.nlm.nih.gov/8497296/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of reduced dynamic range on speech understanding: implications for patients with cochlear implants.

OBJECTIVE: To determine the effect of reduced dynamic range on speech understanding when the speech signals are processed in a manner similar to a 6-channel cochlear implant speech processor. DESIGN: Signals were processed in a manner similar to a 6-channel cochlear implant processor and output as a sum of sine waves with frequencies equal to the center frequencies of the analysis filters. The amplitudes of the sine waves were compressed in a systematic fashion to simulate the effect of reduced dynamic range. The compressed signals were presented to 10 normal-hearing listeners for identification. RESULTS: There was a significant effect of compression for all test materials. The effect of the compression on speech understanding was different for the three test materials (vowels, consonants, and sentences). Vowel recognition was affected the most by the compression, and consonant recognition was affected the least by the compression. Feature analysis indicated that the reception of place information was affected the most. Sentence recognition was moderately affected by the compression. CONCLUSIONS: Dynamic range should affect the speech perception abilities of cochlear implant users. Our results suggest that a relatively wide dynamic range is needed for a high level of vowel recognition and a relatively small dynamic range is sufficient to maintain consonant recognition. We infer from this outcome that, if other factors were held equal, an implant patient with a small dynamic range could achieve moderately high scores on tests of consonant recognition but poor performance on vowel recognition, and that it is more likely for an implant patient with a large dynamic range to obtain high scores on vowel recognition than for an implant patient with a small dynamic range.

Cochlear Implants↗

Enhanced coding in a cochlear-implant model using additive noise: aperiodic stochastic resonance with tuning.

Analog electrical stimulation of the cochlear nerve (the nerve of hearing) by a cochlear implant is an effective method of providing functional hearing to profoundly deaf people. Recent physiological and computational experiments have shown that analog cochlear implants are unlikely to convey certain speech cues by the temporal pattern of evoked nerve discharges. However, these experiments have also shown that the optimal addition of noise to cochlear implant signals can enhance the temporal representation of speech cues [R. P. Morse and E. F. Evans, Nature Medicine 2, 928 (1996)]. We present a simple model to explain this enhancement of temporal representation. Our model derives from a rate equation for the mean threshold-crossing rate of an infinite set of parallel discriminators (level-crossing detectors); a system that well describes the time coding of information by a set of nerve fibers. Our results show that the optimal transfer of information occurs when the threshold level of each discriminator is equal to the root-mean-square noise level. The optimal transfer of information by a cochlear implant is therefore expected to occur when the internal root-mean-square noise level of each stimulated fiber is approximately equal to the nerve threshold. When interpreted within the framework of aperiodic stochastic resonance, our results indicate therefore that for an infinite array of discriminators, a tuning of the noise is still necessary for optimal performance. This is in contrast to previous results [Collins, Chow, and Imhoff, Nature 376, 236 (1995); Chialvo, Longtin, and Müller-Gerking, Phys. Rev. E 55, 1798 (1997)] on arrays of FitzHugh-Nagumo neurons.

Cochlear Implants↗