Search PubMed⌕ Search

PubMed · 8497236

Filter wheel equalization in DSA: simulation results.

Abstract

Digital subtraction angiography (DSA) is a valuable and frequently used diagnostic technique which allows the evaluation of vascular anatomy and pathology. In order to improve the utility and diagnostic performance of DSA, a filter wheel system is presented which can provide mechanically simple, rapidly adaptable, and clinically practical radiographic equalization to DSA images. The filter wheel equalization system consists of a series of computer-driven filter wheels, mounted between the x-ray tube and collimator. Each wheel has an annular area of attenuator material which intersects the x-ray beam and carries a rotationally varying compensation pattern on it. Rotation of the filter wheel modulates the attenuator pattern in the x-ray field under computer control, in a manner designed to increase the x-ray exposure to underexposed areas in the image. A system with eight wheels has 10(19) possible equalization patterns. The compensation patterns are removed in the subtracted DSA images. Computer simulation techniques were used to evaluate various design scenarios for the filter wheel system, using a data base of 191 clinical DSA mask images. For a practical implementation of the filter wheel system, an improvement in the signal to noise ratio of 23%, averaged over the image, was found.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J M Boone, G A Gardiner, D C Levin. Filter wheel equalization in DSA: simulation results.. https://doi.org/10.1118/1.597037

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Patient dose from 3D rotational neurovascular studies.

The use of image-guided interventional radiological techniques is increasing in prevalence and complexity. Imaging system developments have helped improve the information available to interventionalists to plan and guide procedures. Information on doses to patients resulting from alternative imaging techniques or protocols is useful for both the process of justifying particular procedures and in optimizing the resultant exposures. Such information is not always available, especially for new or developing imaging techniques. We have undertaken a study of doses to patients associated with two alternative imaging methods for pre-intervention assessment of intracranial aneurysms. In the first technique the aneurysm is assessed from a series of digital subtraction angiography (DSA) runs taken at different imaging projections. The second technique involved acquiring images from one single image run while the imaging system rotated 180 degrees around the patient's head. In this technique, the aneurysm was then evaluated from a 3D reconstruction of the projection images. Effective doses were calculated using a computer model to simulate the exposure geometry and parameters. The mean dose from the DSA protocol used at our centre was 3.4 mSv and from the 3D rotational angiography (RA) technique was 0.20 mSv.

Angiography, Digital Subtraction↗

Treatment of an Angio-Seal-related vascular complication using the SilverHawk plaque excision system: a case report.

The Angio-Seal is a user-friendly and safe arterial closure device increasingly used after percutaneous diagnostic and interventional procedures. Although it achieves rapid hemostasis and facilitates early patient mobilization, its use can be associated with vascular complications. A specific problem related to the device is protrusion of the collagen plug into the artery, causing either acute occlusion or symptomatic stenosis. When this occurs, treatment with balloon angioplasty alone is usually suboptimal, while stenting of the common femoral artery may be undesirable. In this report we describe a novel application of the SiverHawk plaque excision system to treat a highly eccentric stenosis at the site of a previously deployed Angio-Seal. Since the device allows preferential cutting in the direction of the lesion and collagen plug debulking, it may be ideally suited to treat this complication without the need for stenting of the common femoral artery.

Angiography, Digital Subtraction↗

Carotid artery fibromuscular dysplasia.

Extracranial carotid artery fibromuscular dysplasia (FMD) is a rare finding that is frequently incidental and asymptomatic. It usually occurs in middle-age women and is secondary to medial fibrodysplasia or, less commonly, intimal fibrodysplasia. The carotid artery may be elongated or kinked and associated aneurysms have been reported. Symptoms including transient ischemic attack or stroke are uncommon and are due to low flow or embolization of platelet aggregates. Digital subtraction angiography demonstrates high-grade stenosis with the characteristic "string of beads" pattern. Antiplatelet medication with sequential imaging is the accepted therapy for asymptomatic lesions. Graduated endoluminal dilation under direct vision should be reserved for patients with documented lateralizing symptoms.

Angiography, Digital Subtraction↗