A lesion detectability simulation method for digital x-ray imaging.

A simulation method is described in this work that aids in quantifying the upper limits of lesion detectability as a function of lesion size, lesion contrast, pixel size, and x-ray exposure for digital x-ray imaging systems. The method entails random lesion placement with subsequent simulated imaging on idealized x-ray detectors with no additive noise and 100% quantum detective efficiency. Lesions of different size and thickness were simulated. Mean (expectation) lesion signal-to-noise ratios (LSNRs) were calculated and receiver operating characteristic (ROC) curves were constructed based on LSNR ensembles. Mean (expectation) values of the areas under the ROC curves were calculated for lesions of varying size on pixel arrays of varying size at different exposures. Analyses were performed across several parameters, including lesion size, pixel size, and exposure levels representative of various areas of radiography. As expected, lesion detectability increased with lesion size, contrast, pixel size, and exposure. The model suggests that lesion detectability is strongly dependent on the relative alignment (phase) of the lesion with the pixel matrix for lesions on the order of the pixel size.

Biophysical Phenomena↗

An edge spread technique for measurement of the scatter-to-primary ratio in mammography.

An experimental measurement technique that directly measures the magnitude and spatial distribution of scatter in relation to primary radiation is presented in this work. The technique involves the acquisition of magnified edge spread function (ESF) images with and without scattering material present. The ESFs are normalized and subtracted to yield scatter-to-primary ratios (SPRs), along with the spatial distributions of scatter and primary radiation. Mammography is used as the modality to demonstrate the ESF method, which is applicable to all radiographic environments. Sets of three images were acquired with a modified clinical mammography system employing a flat panel detector for 2, 4, 6, and 8 cm thick breast tissue equivalent material phantoms composed of 0%, 43%, and 100% glandular tissue at four different kV settings. Beam stop measurements of scatter were used to validate the ESF methodology. There was good agreement of the mean SPRs between the beam stop and ESF methods. There was good precision in the ESF-determined SPRs with a coefficient of variation on the order of 5%. SPRs ranged from 0.2 to 2.0 and were effectively independent of energy for clinically realistic kVps. The measured SPRs for 2, 4, and 6 cm 0% glandular phantoms imaged at 28 kV were 0.21+/-0.01, 0.39+/-0.01, and 0.57+/-0.02, respectively. The measured SPRs for 2, 4, and 6 cm 43% glandular phantoms imaged at 28 kV were 0.20+/-0.01, 0.35+/-0.02, and 0.53+/-0.02, respectively. The measured SPRs for 2, 4, and 6 cm 100% glandular phantoms imaged at 28 kV were 0.22+/-0.02, 0.42+/-0.03, and 0.88+/-0.08, respectively.

Biophysical Phenomena↗

A Monte Carlo study of x-ray fluorescence in x-ray detectors.

Advances in digital x-ray detector systems have led to a renewed interest in the performance of x-ray phosphors and other detector materials. Indirect flat panel x-ray detector and charged coupled device (CCD) systems require a more technologically challenging geometry, whereby the x-ray beam is incident on the front side of the scintillator, and the light produced must diffuse to the back surface of the screen to reach the photoreceptor. Direct detector systems based on selenium have also enjoyed a growing interest, both commercially and academically. Monte Carlo simulation techniques were used to study the x-ray scattering (Rayleigh and Compton) and the more prevalent x-ray fluorescence properties of seven different x-ray detector materials, Gd2O2S, CsI, Se, BaFBr, YTaO4, CaWO4, and ThO2. The redistribution of x-ray energy, back towards the x-ray source, in a forward direction through the detector, and lateral reabsorption in the detector was computed under monoenergetic conditions (1 keV to 130 keV by 1 keV intervals) with five detector thicknesses, 30, 60, 90, 120, and 150 mg/cm2 (Se was studied from 30 to 1000 mg/cm2). The radial distribution (related to the point spread function) of reabsorbed x-ray energy was also determined. Representative results are as follows: At 55 keV, more (31.3%) of the incident x-ray energy escaped from a 90 mg/cm2Gd2O2S detector than was absorbed (27.9%). Approximately 1% of the total absorbed energy was reabsorbed greater than 0.5 mm from the primary interaction, for 90 mg/cm2 CsI exposed at 100 kVp. The ratio of reabsorbed secondary (fluorescence + scatter) radiation to the primary radiation absorbed in the detectors (90 mg/cm2) (S/P) was determined as 10%, 16%, 2%, 12%, 3%, 3%, and 0.3% for a 100 kVp tungsten anode x-ray spectrum, for the Gd2O2S, CsI, Se, BaFBr, YTaO4, CaWO4, and ThO2 detectors, respectively. The results indicate significant x-ray fluorescent escape and reabsorption in common x-ray detectors. These findings suggest that x-ray fluorescent radiation redistribution should be considered in the design of digital x-ray imaging systems.

Biophysical Phenomena↗

A multiple detector array helical x-ray microtomography system for specimen imaging.

An x-ray computed microtomography system for specimen and small animal imaging was built and tested. The system used seventeen 48-microm-wide detector arrays (a charge coupled device camera) and helical acquisition techniques. Images were acquired using 540 rays/view and 400 views/2pi. The modulation transfer function (MTF) of the computed tomography images demonstrated 50 microm limiting resolution, with MTF > 10% for objects larger than 60 microm (approximately 8.3 cycles/mm). While soft tissue discrimination was compromised by a low signal-to-noise ratio, equine medullary bone core samples and the murine skeleton were well visualized. The incorporation of multiple detector arrays provided a 17-fold improvement in x-ray efficiency, which is a very important step toward improving the potential of microtomography as a scientific tool.

Algorithms↗

Glandular breast dose for monoenergetic and high-energy X-ray beams: Monte Carlo assessment.

PURPOSE: To extend the utility of normalized glandular dose (DgN) calculations to higher x-ray energies (up to 120 keV) and to provide the tools for investigators to calculate DgN values for arbitrary mammographic and x-ray spectra. MATERIALS AND METHODS: Validated Monte Carlo methods were used to assess DgN values. One million x-ray photons (1-120 keV, in 1-keV increments) were input to a semicircular breast geometry of thicknesses from 2 to 12 cm and breast compositions from 0% to 100% glandular. DgN values for monoenergetic (1-120 keV) x-ray beams, polyenergetic (40-120 kV, tungsten anode) x-ray spectra, and polyenergetic mammographic spectra were computed. Skin thicknesses of 4-5 mm were used. RESULTS: The calculated DgN values were in agreement within approximately 1%-6% with previously published data, depending on breast composition. DgN tables were constructed for a variety of x-ray tube anode-filter combinations, including molybdenum anode-molybdenum filter, molybdenum anode-rhodium filter, rhodium anode-rhodium filter, tungsten anode-rhodium filter, tungsten anode-palladium filter, and tungsten anode-silver filter. DgN values also were graphed for monoenergetic beams to 120 keV and for general diagnostic x-ray beams to 120 kV. CONCLUSION: The tables and graphs may be useful for optimizing mammographic procedures. The higher energy data may be useful for investigations of the potential of dual-energy mammography or for calculation of dose in general diagnostic or computed tomographic procedures.

Breast↗

A breast density index for digital mammograms based on radiologists' ranking.

The purpose of this study was to develop and evaluate a computerized method of calculating a breast density index (BDI) from digitized mammograms that was designed specifically to model radiologists' perception of breast density. A set of 153 pairs of digitized mammograms (cranio-caudal, CC, and mediolateral oblique, MLO, views) were acquired and preprocessed to reduce detector biases. The sets of mammograms were ordered on an ordinal scale (a scale based only on relative rank-ordering) by two radiologists, and a cardinal (an absolute numerical score) BDI value was calculated from the ordinal ranks. The images were also assigned cardinal BDI values by the radiologists in a subsequent session. Six mathematical features (including fractal dimension and others) were calculated from the digital mammograms, and were used in conjunction with single value decomposition and multiple linear regression to calculate a computerized BDI. The linear correlation coefficient between different ordinal ranking sessions were as follows: intraradiologist intraprojection (CC/CC): r = 0.978; intraradiologist interprojection (CC/MLO): r = 0.960; and interradiologist intraprojection (CC/CC): r = 0.968. A separate breast density index was derived from three separate ordinal rankings by one radiologist (two with CC views, one with the MLO view). The computer derived BDI had a correlation coefficient (r) of 0.907 with the radiologists' ordinal BDI. A comparison between radiologists using a cardinal scoring system (which is closest to how radiologists actually evaluate breast density) showed r = 0.914. A breast density index calculated by a computer but modeled after radiologist perception of breast density may be valuable in objectively measuring breast density. Such a metric may prove valuable in numerous areas, including breast cancer risk assessment and in evaluating screening techniques specifically designed to improve imaging of the dense breast.

Algorithms↗

Angiographic film subtraction using a laser digitizer and computer processing.

Digital subtraction angiography has been accepted as an invaluable clinical tool over the past decade; however, film-screen-based angiography is still performed routinely when high-resolution or large field-of-view angiograms are needed. A technique is presented whereby two films from an angiographic sequence are digitized using a high-resolution laser digitizer, and the digitized images are aligned, subtracted, and displayed using the computer. To accommodate for some types of patient motion, an image warping algorithm is presented and discussed in detail. The warping algorithm is piecewise linear, using triangular regions for warping, resulting in a global nonlinear transform across triangle elements. An algorithm describing optimal triangle selection also is discussed. The results show that subtraction images of excellent quality can be produced by the proposed technique, and suggest that, in some settings, digitized subtraction films may be preferred over conventional film subtraction.

Angiography, Digital Subtraction↗

Mammography spectrum measurement using an x-ray diffraction device.

The use of a diffraction spectrometer developed by Deslattes for the determination of mammographic kV is extended to the measurement of accurate, relative x-ray spectra. Raw x-ray spectra (photon fluence versus energy) are determined by passing an x-ray beam through a bent quartz diffraction crystal, and the diffracted x-rays are detected by an x-ray intensifying screen coupled to a charge coupled device. Two nonlinear correction procedures, one operating on the energy axis and the other operating on the fluence axis, are described and performed on measured x-ray spectra. The corrected x-ray spectra are compared against tabulated x-ray spectra measured under nearly identical conditions. Results indicate that the current device is capable of producing accurate relative x-ray spectral measurements in the energy region from 12 keV to 40 keV, which represents most of the screen-film mammography energy range. Twelve keV is the low-energy cut-off, due to the design geometry of the device. The spectrometer was also used to determine the energy-dependent x-ray mass attenuation coefficients for aluminium, with excellent results in the 12-30 keV range. Additional utility of the device for accurately determining the attenuation characteristics of various normal and abnormal breast tissues and phantom substitutes is anticipated.

Biophysical Phenomena↗

An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV.

A tungsten anode spectral model using interpolating polynomials (TASMIP) was used to compute x-ray spectra at 1 keV intervals over the range from 30 kV to 140 kV. The TASMIP is not semi-empirical and uses no physical assumptions regarding x-ray production, but rather interpolates measured constant potential x-ray spectra published by Fewell et al. [Handbook of Computed Tomography X-ray Spectra (U.S. Government Printing Office, Washington, D.C., 1981)]. X-ray output measurements (mR/mAs measured at 1 m) were made on a calibrated constant potential generator in our laboratory from 50 kV to 124 kV, and with 0-5 mm added aluminum filtration. The Fewell spectra were slightly modified (numerically hardened) and normalized based on the attenuation and output characteristics of a constant potential generator and metal-insert x-ray tube in our laboratory. Then, using the modified Fewell spectra of different kVs, the photon fluence phi at each 1 keV energy bin (E) over energies from 10 keV to 140 keV was characterized using polynomial functions of the form phi (E) = a0[E] + a1[E] kV + a2[E] kV2 + ... + a(n)[E] kVn. A total of 131 polynomial functions were used to calculate accurate x-ray spectra, each function requiring between two and four terms. The resulting TASMIP algorithm produced x-ray spectra that match both the quality and quantity characteristics of the x-ray system in our laboratory. For photon fluences above 10% of the peak fluence in the spectrum, the average percent difference (and standard deviation) between the modified Fewell spectra and the TASMIP photon fluence was -1.43% (3.8%) for the 50 kV spectrum, -0.89% (1.37%) for the 70 kV spectrum, and for the 80, 90, 100, 110, 120, 130 and 140 kV spectra, the mean differences between spectra were all less than 0.20% and the standard deviations were less than approximately 1.1%. The model was also extended to include the effects of generator-induced kV ripple. Finally, the x-ray photon fluence in the units of photons/mm2 per mR was calculated as a function of HVL, kV, and ripple factor, for various (water-equivalent) patient thicknesses (0, 10, 20, and 30 cm). These values may be useful for computing the detective quantum efficiency, DQE(f), of x-ray detector systems. The TASMIP algorithm and ancillary data are made available on line at http:/(/)www.aip.org/epaps/epaps.html.

Algorithms↗

Lens coupling efficiency: derivation and application under differing geometrical assumptions.

The calculation of lens coupling efficiency is often performed in the design of lens coupled digital radiographic system, now currently under development. With these systems, an electronic camera is focused onto a planar scintillator such as a conventional intensifying screen. Historically, this calculation has relied on certain assumptions concerning the emission properties of the scintillator, and primarily this assumption is that the scintillator is either a Lambertain emitter (light is emitted over all angles equally) or a point radiator. Because there now exists new classes of scintillators such as scintillating fiber optic screens and pixelated intensifying screens, it is sometimes necessary to perform lens coupling calculations in the absence of the Lambertian and point source assumptions. In this paper we describe the necessary equations to accurately calculate lens coupling efficiency in the most general of cases. Graphical examples demonstrate the lens coupling efficiency for hypothetical Lambertain scintillating sources, for a rare earth intensifying screen, and for a scintillating fiber optical screen.

Electronics↗

Scintillating fiber optic screens: a comparison of MTF, light conversion efficiency, and emission angle with Gd2O2S:Tb screens.

The widespread effort in developing digital imaging systems has led to large area high pixel density photodetectors such as charge coupled devices (CCDs), amorphous silicon photodiode arrays, and complementary metal oxide semiconductor (CMOS) imagers. These photodetectors have different capabilities, characteristics, and requirements than conventional silver-halide-based film, and this fact had led to a new generation of exotic scintillators, including fiber optic screens made from scintillating glass. The scintillator performance characteristics of five different scintillating fiber optic screens and two conventional Gd2O2S:Tb screens (one 34 mg/cm2 and the other 60 mg/cm2) were measured and compared. The measurements that were made included the angular dependence of light emission relative to the normal, the modulation transfer function (MTF), and the absolute effective conversion efficiency (light photons per absorbed x-ray photon). It was found that the light emission of scintillating fiber optic screens is markedly forward peaked (depending on the sample) compared to conventional screens or Lambertian emitters. The MTFs of the five scintillating fiber optic screens measured were comparable and fell approximately midway between the two conventional screen MTFs. One of the scintillating fiber optic screens demonstrated light efficiency similar to the thick (60 mg/cm2) conventional screen, another had light output capabilities similar to the thin (34 mg/cm2) conventional screen, and the three others were less efficient than the thin screen. The non-Lambertian characteristics of the fiber optic scintillators will cause errors of up to 75% in lens efficiency calculations if a Lambertian source is assumed. The conventional screens were found to conform within about 5% of an ideal Lambertian emitter.

Biophysical Phenomena↗

Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography.

Computer simulation is a convenient and frequently used tool in the study of x-ray mammography, for the design of novel detector systems, the evaluation of dose deposition, x-ray technique optimization, and other applications. An important component in the simulation process is the accurate computer-generation of x-ray spectra. A computer model for the generation of x-ray spectra in the mammographic energy range from 18 kV to 40 kV has been developed. The proposed model requires no assumptions concerning the physics of x-ray production in an x-ray tube, but rather makes use of x-ray spectra recently measured experimentally in the laboratories of the Center for Devices and Radiological Health. Using x-ray spectra measured for molybdenum, rhodium, and tungsten anode x-ray tubes at 13 different kV's (18, 20, 22, ..., 42 kV), a spectral model using interpolating polynomials was developed. At each energy in the spectrum, the x-ray photon fluence was fit using 2, 3, or 4 term (depending on the energy) polynomials as a function of the applied tube voltage (kV). Using the polynomial fit coefficients determined at each 0.5 keV interval in the x-ray spectrum, accurate x-ray spectra can be generated for any arbitrary kV between 18 and 40 kV. Each anode material (Mo, Rh, W) uses a different set of polynomial coefficients. The molybdenum anode spectral model using interpolating polynomials is given the acronym MASMIP, and the rhodium and tungsten spectral models are called RASMIP and TASMIP, respectively. It is shown that the mean differences in photon fluence calculated over the energy channels and over the kV range from 20 to 40 kV were -0.073% (sigma = 1.58%) for MASMIP, -0.145% (sigma = 1.263%) for RASMIP, and 0.611% (sigma = 2.07%) for TASMIP. The polynomial coefficients for all three models are given in an Appendix. A short C subroutine which uses the polynomial coefficients and generates x-ray spectra based on the proposed model is available on the World Wide Web at http:/(/)www.aip.org/epaps/epaps.html.

Aluminum↗

Sinusoidal modulation analysis for optical system MTF measurements.

The modulation transfer function (MTF) is a commonly used metric for defining the spatial resolution characteristics of imaging systems. While the MTF is defined in terms of how an imaging system demodulates the amplitude of a sinusoidal input, this approach has not been in general use to measure MTFs in the medical imaging community because producing sinusoidal x-ray patterns is technically difficult. However, for optical systems such as charge coupled devices (CCD), which are rapidly becoming a part of many medical digital imaging systems, the direct measurement of modulation at discrete spatial frequencies using a sinusoidal test pattern is practical. A commercially available optical test pattern containing spatial frequencies ranging from 0.375 cycles/mm to 80 cycles/mm was sued to determine the MRF of a CCD-based optical system. These results were compared with the angulated slit method of Fujita [H. Fujita, D. Tsia, T. Itoh, K. Doi, J. Morishita, K. Ueda, and A. Ohtsuka, "A simple method for determining the modulation transfer function in digital radiography," IEEE Trans. Medical Imaging 11, 34-39 (1992)]. The use of a semiautomated profiled iterated reconstruction technique (PIRT) is introduced, where the shift factor between successive pixel rows (due to angulation) is optimized iteratively by least-squares error analysis rather than by hand measurement of the slit angle. PIRT was used to find the slit angle for the Fujita technique and to find the sine-pattern angle for the sine-pattern technique. Computer simulation of PIRT for the case of the slit image (a line spread function) demonstrated that it produced a more accurate angle determination than "hand" measurement, and there is a significant difference between the errors in the two techniques (Wilcoxon Signed Rank Test, p < 0.001). The sine-pattern method and the Fujita slit method produced comparable MTF curves for the CCD camera evaluated.

Biophysical Phenomena↗

Comparison of x-ray cross sections for diagnostic and therapeutic medical physics.

The purpose of this technical report is to make available an up-to-date source of attenuation coefficient data to the medical physics community, and to compare these data with other more familiar sources. Data files from Lawrence Livermore National Laboratory (in Livermore, CA) were truncated to match the needs of the medical physics community, and an interpolation routine was written to calculate a continuous set of cross sections spanning energies from 1 keV to 50 MeV. Coefficient data are available for elements Z = 1 through Z = 100. Values for mass attenuation coefficients, mass-energy-transfer coefficients, and mass-energy absorption coefficients are produced by a single computer subroutine. In addition to total interaction cross sections, the cross sections for photoelectric, Rayleigh, Compton, pair, and some triplet interactions are also produced by this single program. The coefficients were compared to the 1970 data of Storm and Israel over the energy interval from 1 to 1000 keV; for elements 10, 20, 30, 40, 50, 60, 70, and 80, the average positive difference between the Storm and Israel coefficients and the coefficients reported here are 1.4%, 2.7%, and 2.6%, for the mass attenuation, mass energy-transfer, and mass-energy absorption coefficients, respectively. The 1969 data compilation of mass attenuation coefficients from McMaster et al. were also compared with the newer LLNL data. Over the energy region from 10 keV to 1000 keV, and from elements Z = 1 to Z = 82 (inclusive), the overall average difference was 1.53% (sigma = 0.85%). While the overall average difference was small, there was larger variation (> 5%) between cross sections for some elements. In addition to coefficient data, other useful data such as the density, atomic weight, K, L1, L2, L3, M, and N edges, and numerous characteristic emission energies are output by the program, depending on a single input variable. The computer source code, written in C, can be accessed and downloaded from the World Wide Web at: http:@www.aip.org/epaps/epaps.html [E-MPHSA-23-1977].

Biophysical Phenomena↗

Medical physics.

Explore the source record for details and available documents.

Biophysics↗

Filter wheel equalization for chest radiography: a computer simulation.

A chest radiographic equalization system using lung-shaped templates mounted on filter wheels is under development. Using this technique, 25 lung templates for each lung are available on two computer controlled wheels which are located in close proximity to the x-ray tube. The large magnification factor (> 10X) of the templates assures low-frequency equalization due to the blurring of the focal spot. A low-dose image is acquired without templates using a (generic) digital receptor, the image is analyzed, and the left and right lung fields are automatically identified using software developed for this purpose. The most appropriate left and right lung templates are independently selected and are positioned into the field of view at the proper location under computer control. Once the templates are positioned, acquisition of the equalized radiographic image onto film commences at clinical exposure levels. The templates reduce the exposure to the lung fields by attenuating a fraction of the incident x-ray fluence so that the exposure to the mediastinum and diaphragm areas can be increased without overexposing the lungs. A data base of 824 digitized chest radiographs was used to determine the shape of the specific lung templates, for both left and right lung fields. A second independent data base of 208 images was used to test the performance of the templates using computer simulations. The template shape characteristics derived from the clinical image data base are demonstrated. The detected exposure in the lung fields on conventional chest radiographs was found to be, on average, three times the detected exposure behind the diaphragm and mediastinum.(ABSTRACT TRUNCATED AT 250 WORDS)

Biophysical Phenomena↗

A fully automated algorithm for the segmentation of lung fields on digital chest radiographic images.

A completely automated algorithm is presented which is capable of identifying both the right- and left-lung fields on digitized chest radiographic images. The algorithm is tested on a sample of 802 chest images against lung fields drawn by a human observer. The average accuracies are found to be 0.957 +/- 0.003 and 0.960 +/- 0.003 for right- and left-lung regions, respectively. To put them into perspective, the results are compared to several other simple segmentation techniques. These include a comparison of two sets of lung fields drawn by the human observer at different times which yielded accuracies of 0.967 +/- 0.005 and 0.967 +/- 0.004 for right- and left-lung regions, respectively.

Algorithms↗

Pediatric skeletal age: determination with neural networks.

PURPOSE: To develop a neural network to calculate skeletal age based on measurements taken from digitized hand radiographs. MATERIALS AND METHODS: From a database of 521 hand radiographs obtained in healthy patients, four parameters were calculated from seven linear measurements and were used to train a neural network, with use of the jackknife method, to calculate skeletal age. The results were compared with those of an experienced pediatric radiologist using a standard pediatric skeletal atlas. RESULTS: The mean difference from biologic age for the neural network was -0.261 years +/- 1.82 (standard deviation) and for the radiologist, -0.232 years +/- 1.54; this difference was not significantly different (P = .67, Wilcoxon signed rank test). Skeletal age determined by the neural network was closer to the biologic age than that assigned by the radiologist in 243 of 521 cases (47%). CONCLUSION: A simple neural network may assist radiologists in the assessment of skeletal age.

Adolescent↗