Search PubMedSearch

PubMed · 8483901

Predicting protein diffusion coefficients.

Abstract

Diffusion coefficients for proteins in water are predicted. The numerical method developed is general enough to be applied to a wide range of protein surface shapes, from rodlike to globular. Results are presented for lysozyme and tobacco mosaic virus, and they are compared with actual data and with predictions made by less general methods.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Brune, S Kim. 1993-05-01. Predicting protein diffusion coefficients.. https://doi.org/10.1073/pnas.90.9.3835

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Lifetime enhancement of ultrasmall fluorescent liquid polymeric film based optodes by diffusion-induced self-recovery after photobleaching.

The major concern with optodes, especially miniaturized ones, has been their photobleaching limited lifetime. Liquid polymer [highly plasticized poly(vinyl chloride)] films are commonly used to prepare fluorescent optical fiber sensors. A major advantage is the ease of their fabrication. It is demonstrated here that, with proper choice of excitation power and illumination time, the sensor will completely recover itself from photobleaching after each measurement. This self-recovery is demonstrated on single-mode optical fibers with 80 microns diameter (3.1 microns active region) and on near-field scanning optical microscope pulled fiber tips with submicrometer diameter (250 nm active region). The single-mode optode can be used for 30,000 measurements with only a 5% signal loss at a signal/noise of > 66. This opens the way for prolonged ratiometric application of such optodes.

Diffusion

Complexometric determination of metal ions by microscopic diffusional titration.

Acid/base titrations of pico- and femtoliter microsamples have been performed previously using a diffusional microburet (DMB) for reagent delivery in a simple droplet-heptane system (Gratzl, M.; Yi, C. Anal. Chem. 1993, 65, 2085-2088). The lowest delivery rate achieved with a DMB was about 6 fmol/s, which would correspond to about a 1 microL/year volumetric flow rate with a hypothetical equivalent mechanical delivery scheme (Yi, C.; Gratzl, M. Anal. Chem. 1994, 66, 1976-1982). In this work, the feasibility of complexometric titrations in microscopic samples is explored. Stability of pH in the microdroplets required for different determinations and the effects of DMB shank geometry on titration characteristics are also studied. Diffusional microtitrations of Fe(III), Zn(II), and Cu(II) have been performed with EDTA. Xylenol orange and Eriochrome Black T provide clear color changes at the end point of the respective titrations, despite the microscopic size of the samples (between 16 and 1570 pL, corresponding to diameters between 30 and 144 microns). Random errors of the determinations relative to full scale were 6.6% for Fe(III), 5.8% for Cu(II), and 7.9% for Zn(II). The pH required for EDTA titrations of the individual metal ions stays stable in the acidic range. This makes the microscopic titration of a number of metal ions, such as Fe(III), Fe(II), Cu(II), and Pb(II), feasible in a simple droplet-heptane system without any modification. With a higher density of strongly alkaline buffer droplets (about 100 droplets/mm2) sprayed on the bottom of the Petri dish, or by flushing N2 above the heptane, the microscopic samples can also be kept alkaline despite ambient CO2 present. In this way, Zn(II) can also be titrated in microdroplets, requiring a pH around 10. This work renders it possible to perform a variety of complexometric titrations and other chemical manipulations in microdroplets even if they need to be kept alkaline. Similar titrations in single biological cells to assess intracellular buffer capacities of different metal ions, such as Ca(II) and Mg(II), are underway.

Diffusion