Search PubMedSearch

PubMed · 8482209

[Osteopathy].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Beck. 1993. [Osteopathy].. https://pubmed.ncbi.nlm.nih.gov/8482209/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Removed shunt valves: reasons for failure and implications for valve design.

Most removed shunt valves are discarded with no investigation into why they had to be replaced or whether they still performed to specification. However, improvements in valve design will only occur if valves that have needed removal are examined and the reasons that they failed are determined. An in-depth study of 43 valves that were removed in this unit over a 15-month period was performed. They were submitted to a four-part study, comprising flow-pressure testing, opening and closing pressure measurement, assessment of the susceptibility to syphoning, and dismantling with internal inspection of the valve components. Overall, 81% of valves failed to meet the manufacturers' specified performance data, even though the peroperative cause of shunt failure was thought to lie outside the valve. Over 80% of valves with metallic parts were found to have accumulated debris internally, and this was thought to have impaired their performance. In contrast, only 25% of non-metallic valves contained debris, a significant difference (0.01 > p > 0.001). All of the valves had a high tendency to overdrainage. Attention is drawn to the high number of malfunctioning valves. It is recommended that a change of valve should be considered in all shunt revisions, and that future valve designs should avoid metal components.

Cerebrospinal Fluid Pressure

Laboratory testing of three intracranial pressure microtransducers: technical report.

Three comparatively priced intracranial pressure (ICP) microtransducers are now available, each characterized by the manufacturer as having very low zero drift over long periods, an excellent frequency response, and a low measurement error. The three microtransducers, coded Transducer A (Camino OLM ICP monitor; Camino Laboratories, San Diego, CA), Transducer B (Codman Microsensor ICP Transducer; Codman & Shurtlef Inc., Randolph, MA), and Transducer C (ICP Monitoring Catheter Kit OPX-SD [4F]; InnerSpace Medical, Irvine, CA), were examined in a pressure-flow test rig designed for assessment of hydrocephalus shunts. All three microtransducers compiled with the manufacturers' specifications and gave high-quality readings under test conditions. However, some differences were noted; Transducer C had the lowest 24-hour zero drift (drifts in all transducers were < 0.8 mm Hg). The temperature drift was very low in Transducer B and C, but Transducer A had a significantly higher drift (0.27 mm Hg/degrees C). Transducer A had a static error < 0.3 mm Hg, Transducer B < 2 mm Hg, and Transducer C < 8 mm Hg. Frequency detection in Transducers A and B were very good (bandwidth, > 30 Hz), whereas Transducer C had a limited bandwidth of 20 Hz. Transducer B scored the best overall, but all three scored satisfactorily during bench testing.

Cerebrospinal Fluid Pressure