Search PubMed⌕ Search

PubMed · 8378955

Between-method correlation in quantifying internal carotid stenosis.

Abstract

BACKGROUND AND PURPOSE: The degree of internal carotid stenosis has emerged as the most important predictor of ischemic stroke in extracranial carotid artery disease. The purpose of this study was to assess the validity of the noninvasive techniques for quantifying internal carotid stenosis with respect to the accepted standard of intra-arterial angiography. METHODS: We measured the maximum percentage reduction in luminal diameter on the intra-arterial digital subtraction angiograms of 56 symptomatic patients with extracranial internal carotid stenosis (n = 77) or occlusion (n = 20). These data were compared with independent measurements based on continuous-wave Doppler ultrasonography, pulsed-wave Doppler spectrum analysis, color Doppler-assisted duplex imaging, and magnetic resonance angiography. RESULTS: Correlations with intra-arterial angiography were equally strong (r > .90) for magnetic resonance angiography, continuous-wave Doppler, and color duplex analysis. Positive and negative predictive values for (therapeutically relevant) 70% to 99% stenosis were higher for continuous-wave Doppler (.82, .97) and color duplex (.84, .98) than for magnetic resonance angiography (.79, .81). Also, accuracy in quantifying high-grade stenosis was better for both of these ultrasonographic techniques, mainly due to the frequent occurrence of a "flow gap" on the magnetic resonance angiograms. Continuous-wave Doppler and magnetic resonance angiography, but not color duplex, failed to detect slow residual arterial flow in one and two cases of symptomatic "pseudo-occlusion" of the internal carotid, respectively. CONCLUSIONS: (1) Several noninvasive methods compare well with intra-arterial angiography in identifying and quantifying high-grade internal carotid stenosis; (2) the use of these noninvasive methods may suffice for treatment decisions; and (3) because residual between-method disagreement is partly explained by principles of physics, the validity of continuous-wave Doppler and color duplex in quantifying 60% to 99% stenosis is likely to be underestimated by correlation with intra-arterial angiography.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Sitzer, G Fürst, H Fischer, M Siebler, T Fehlings, A Kleinschmidt, T Kahn, H Steinmetz. 1993. Between-method correlation in quantifying internal carotid stenosis.. https://doi.org/10.1161/01.str.24.10.1513

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Vascular bed origin dictates flow pattern regulation of endothelial adhesion molecule expression.

Endothelial cell phenotypes markedly differ, depending upon function and vascular bed of origin. Differences might account for specific susceptibility to pathological conditions. As leukocyte adhesion to activated endothelium is the initiating event in a range of diseases, we compared the influence of vascular bed-specific flow patterns on adhesion molecule expression in human saphenous vein (HSVEC) and coronary artery endothelial cells (HCAEC). In vitro, immune cell attachment was increased 1.6-fold when tumor necrosis factor (TNF)-alpha-stimulated HSVEC were exposed to coronary artery flow in place of physiological venous flow and 1.9-fold higher compared with attachment to cytokine-stimulated HCAEC exposed to coronary artery flow. This was associated with increased concentrations of soluble E-selectin, VCAM-1, and ICAM-1 in supernatants of HSVEC exposed to coronary artery flow compared with HCAEC exposed to the same flow pattern. Venous and coronary artery flow both increased TNF-alpha-induced E-selectin and ICAM-1 expression on HSVEC, but only coronary artery flow increased VCAM-1 expression. In marked contrast to HSVEC, venous and coronary artery flow attenuated TNF-alpha-induced E-selectin and VCAM-1 expression on HCAEC, whereas coronary artery flow further induced ICAM-1 on cytokine-stimulated HCAEC. With the exception of cytokine-induced ICAM-1, adhesion molecule expression on HSVEC exposed to coronary artery flow exceeded expression on HCAEC. Thus ICAM-1 expression involves complex flow-dependent and -independent pathways with marked dissimilarities between the two endothelial cell types studied. Interestingly, Kruppel-like factor (KLF) 4 overexpression in HCAEC and HSVEC significantly reduced TNF-alpha-induced E-selectin and VCAM-1 expression in static conditions, while ICAM-1 expression remained constant. Furthermore, both flow patterns induced KLF2 and KLF4 expression in HCAEC and HSVEC. Venous and coronary artery flow differentially influence endothelial adhesion molecule and transcription factor expression, depending on the vascular bed of origin. Differences in adhesion molecule expression and subsequent immune cell adhesion between HSVEC and HCAEC may contribute to different susceptibility to pathological conditions.

Blood Flow Velocity↗

Mesoscale simulation of blood flow in small vessels.

Computational modeling of blood flow in microvessels with internal diameter 20-500 microm is a major challenge. It is because blood in such vessels behaves as a multiphase suspension of deformable particles. A continuum model of blood is not adequate if the motion of individual red blood cells in the suspension is of interest. At the same time, multiple cells, often a few thousands in number, must also be considered to account for cell-cell hydrodynamic interaction. Moreover, the red blood cells (RBCs) are highly deformable. Deformation of the cells must also be considered in the model, as it is a major determinant of many physiologically significant phenomena, such as formation of a cell-free layer, and the Fahraeus-Lindqvist effect. In this article, we present two-dimensional computational simulation of blood flow in vessels of size 20-300 microm at discharge hematocrit of 10-60%, taking into consideration the particulate nature of blood and cell deformation. The numerical model is based on the immersed boundary method, and the red blood cells are modeled as liquid capsules. A large RBC population comprising of as many as 2500 cells are simulated. Migration of the cells normal to the wall of the vessel and the formation of the cell-free layer are studied. Results on the trajectory and velocity traces of the RBCs, and their fluctuations are presented. Also presented are the results on the plug-flow velocity profile of blood, the apparent viscosity, and the Fahraeus-Lindqvist effect. The numerical results also allow us to investigate the variation of apparent blood viscosity along the cross-section of a vessel. The computational results are compared with the experimental results. To the best of our knowledge, this article presents the first simulation to simultaneously consider a large ensemble of red blood cells and the cell deformation.

Blood Flow Velocity↗

Doppler sonography evaluation of flow velocity and volume of the extracranial internal carotid and vertebral arteries in healthy adults.

PURPOSE: To measure with Doppler sonography the velocity and volume of blood flow in the extracranial internal carotid artery (ICA) and vertebral artery (VA) of healthy adults and to calculate total cerebral blood flow volume (tCBFV). METHODS: Bilateral ICA and VA were examined sonographically in 180 healthy adults. Angle-corrected peak systolic (Vps), end-diastolic (Ved), and time-averaged maximum blood flow velocity (TAV) were measured in pulsed Doppler mode, and the resistance index (RI) and pulsatility index (PI) were calculated. The cross-sectional area (A) was measured on gray-scale images. Volume flow was calculated as FV = TAV x A, and tCBFV was calculated as the sum of the right and left ICA and VA volume flow. RESULTS: tCBFV was 651 +/- 96 ml/min for the entire population. There was a significant decrease in Vps, Ved, TAV, and tCBFV with age in all arteries. RI and PI values initially declined and then increased with age. Cross-sectional area increased with age in ICA but not in VA. PI and RI were higher in men than in women. Blood flow velocity and volume were higher, and RI was lower in the left than in the right VA. CONCLUSION: The Doppler sonographic assessment of extracranial ICA and VA blood flow volume may be useful for the study of cerebral hemodynamic changes in patients with cerebrovascular disorders. Age-dependent changes should be considered, for instance, in the management of intensive care patients with impaired cerebral perfusion.

Blood Flow Velocity↗