PubMed · 827323
The real bladder electromyogram.
Abstract
The nature of bladder electrical activity was investigated in anaesthetised cats and 1 baboon. A time-locked muscle response to sacral ventral root stimulation was most clearly detected within a 10-40 Hz frequency band, the response preceding the rise in intravesical pressure. During reflex voiding only activity in the 10-40 Hz band was consistently related to reflex voiding and to the small contractions leading up to voiding. It is concluded that only a very limited part of the wide band electrical activity recorded from the bladder can be considered genuine electromyogram and that the 10-40 Hz frequency band probably excludes the worst of the artefact. Possible sources of artefact and their relation to changes in intravesical pressure are presented in Table I.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
M D Craggs, J D Stephenson. 1976. The real bladder electromyogram.. https://doi.org/10.1111/j.1464-410x.1976.tb06678.x
Cite the original work for its findings. Save a collection to share your selection of sources.