Three-dimensional subzone-based reconstruction algorithm for MR elastography.

Accurate characterization of harmonic tissue motion for realistic tissue geometries and property distributions requires knowledge of the full three-dimensional displacement field because of the asymmetric nature of both the boundaries of the tissue domain and the location of internal mechanical heterogeneities. The implications of this for magnetic resonance elastography (MRE) are twofold. First, for MRE methods which require the measurement of a harmonic displacement field within the tissue region of interest, the presence of 3D motion effects reduces or eliminates the possibility that simpler, lower-dimensional motion field images will capture the true dynamics of the entire stimulated tissue. Second, MRE techniques that exploit model-based elastic property reconstruction methods will not be able to accurately match the observed displacements unless they are capable of accounting for 3D motion effects. These two factors are of key importance for MRE techniques based on linear elasticity models to reconstruct mechanical tissue property distributions in biological samples. This article demonstrates that 3D motion effects are present even in regular, symmetric phantom geometries and presents the development of a 3D reconstruction algorithm capable of discerning elastic property distributions in the presence of such effects. The algorithm allows for the accurate determination of tissue mechanical properties at resolutions equal to that of the MR displacement image in complex, asymmetric biological tissue geometries. Simulation studies in a realistic 3D breast geometry indicate that the process can accurately detect 1-cm diameter hard inclusions with 2.5x elasticity contrast to the surrounding tissue.

Algorithms↗

Dartmouth's next generation EIS system: preliminary hardware considerations.

Our previous system covered the frequency range of 0 to 1 MHz. In this new design we propose to cover the range from 0 to 10 MHz. The higher frequencies have forced us to reconsider several design decisions in view of both the physics of the problem and the performance of available electronic components. In this presentation we examine in detail the constraints faced by the designer, starting from wiring consideration to measurement techniques. We will also present the solutions we selected to overcome the limitations we discovered. The problems include phase detection, amplitude measurements, system organization and layout and finally system calibration.

Breast Neoplasms↗

An improved data acquisition method for electrical impedance tomography.

Isaacson, Cheney and Seager have demonstrated that simultaneously applying trigonometric patterns of current to a circular electrode array optimizes the sensitivity of EIT to inner structure. We have found that it is less desirable to measure voltage at an electrode that also applies a current due to variable contact impedance. In order to preserve the optimum sensitivity while minimizing the effect of electrode artefacts, we have devised an approach where we sequentially apply a current between each individual electrode and a separate, fixed ground while measuring voltages at all other electrodes for each consecutive current impulse. By adding weighted sums of both the applied currents and corresponding measured voltages from individual passes, we can synthesize trigonometric patterns of any spatial frequency. Since only one of the electrodes in any given acquired data set is used as a source, this approach significantly dilutes the effect of contact impedance on the resulting voltage measurements. We present simulated data showing the equivalency between the synthesized and actual trigonometric excitation patterns. In addition, we report experimental data, both in vitro and in vivo, that show improved results using this data acquisition technique.

Adult↗

Modeling of retraction and resection for intraoperative updating of images.

OBJECTIVE: Intraoperative tissue deformation that occurs during the course of neurosurgical procedures may compromise patient-to-image registration, which is essential for image guidance. A new approach to account for brain shift, using computational methods driven by sparsely available operating room (OR) data, has been augmented with techniques for modeling tissue retraction and resection. METHODS: Modeling strategies to arbitrarily place and move an intracranial retractor and to excise designated tissue volumes have been implemented within a computationally tractable framework. To illustrate these developments, a surgical case example, which uses OR data and the preoperative neuroanatomic image volume of the patient to generate a highly resolved, heterogeneous, finite-element model, is presented. Surgical procedures involving the retraction of tissue and the resection of a left frontoparietal tumor were simulated computationally, and the simulations were used to update the preoperative image volume to represent the dynamic OR environment. RESULTS: Retraction and resection techniques are demonstrated to accurately reflect intraoperative events, thus providing an approach for near-real-time image-updating in the OR. Information regarding subsurface deformation and, in particular, changing tumor margins is presented. Some of the current limitations of the model, with respect to specific tissue mechanical responses, are highlighted. CONCLUSION: The results presented demonstrate that complex surgical events such as tissue retraction and resection can be incorporated intraoperatively into the model-updating process for brain shift compensation in high-resolution preoperative images.

Brain Neoplasms↗

Microwave image reconstruction utilizing log-magnitude and unwrapped phase to improve high-contrast object recovery.

Reconstructing images of large high-contrast objects with microwave methods has proved difficult. Successful images have generally been obtained by using a priori information to constrain the image reconstruction to recover the correct electromagnetic property distribution. In these situations, the measured electric field phases as a function of receiver position around the periphery of the imaging field-of-view vary rapidly often undergoing changes of greater than pi radians especially when the object contrast and illumination frequency increase. In this paper, we introduce a modified form of a Maxwell equation model-based image reconstruction algorithm which directly incorporates log-magnitude and phase of the measured electric field data. By doing so, measured phase variation can be unwrapped and distributed over more than one Rieman sheet in the complex plane. Simulation studies and microwave imaging experiments demonstrate that significant image quality enhancements occur with this approach for large high-contrast objects. Simple strategies for visualizing and unwrapping phase values as a function of the transmitter and receiver positions within our microwave imaging array are described. Metrics of the degree of phase variation expressed in terms of the amount and extent of phase wrapping are defined and found to be figures-of-merit which estimate when it is critical to deploy the new image reconstruction approach. In these cases, the new algorithm recovers high-quality images without resorting to the use of a priori information on object contrast and/or size as previously required.

Algorithms↗

Magnetic resonance elastography using 3D gradient echo measurements of steady-state motion.

Magnetic resonance elastography (MRE) is an important new method used to measure the elasticity or stiffness of tissues in vivo. While there are many possible applications of MRE, breast cancer detection and classification is currently the most common. Several groups have been developing methods based on MR and ultrasound (US). MR or US is used to estimate the displacements produced by either quasi-static compression or dynamic vibration of the tissue. An important advantage of MRE is the possibility of measuring displacements accurately in all three directions. The central problem in most versions of MRE is recovering elasticity information from the measured displacements. In previous work, we have presented simulation results in two and three dimensions that were promising. In this article, accurate reconstructions of elasticity images from 3D, steady-state experimental data are reported. These results are significant because they demonstrate that the process is truly three-dimensional even for relatively simple geometries and phantoms. Further, they show that the integration of displacement data acquisition and elastic property reconstruction has been successfully achieved in the experimental setting. This process involves acquiring volumetric MR phase images with prescribed phase offsets between the induced mechanical motion and the motion-encoding gradients, converting this information into a corresponding 3D displacement field and estimating the concomitant 3D elastic property distribution through model-based image reconstruction. Fully 3D displacement fields and resulting elasticity images are presented for single and multiple inclusion gel phantoms.

Algorithms↗

A two-stage microwave image reconstruction procedure for improved internal feature extraction.

We have developed a two-stage Gauss-Newton reconstruction process with an automatic procedure for determining the regularization parameter. The combination is utilized by our microwave imaging system and has facilitated recovery of quantitatively improved images. The first stage employs a Levenberg-Marquardt regularization along with a spatial filtering technique for a few iterations to produce an intermediate image. In effect, the first set of iterative image reconstruction steps synthesizes a priori information from the measurement data versus actually requiring physical prior information on the interrogated object. Because of the interaction of the Levenberg-Marquardt regularization and spatial filtering at each iteration, the intermediate image produced from the first reconstruction stage represents an improvement in terms of the least squared error over the initial uniform guess; however, it has not completely converged in a least squared sense. The second stage involves using this distribution as a priori information in an iteratively regularized Gauss-Newton reconstruction with a weighted Euclidean distance penalty term. The penalized term restricts the final image to a vicinity (determined by the scale of the weighting parameter) about the intermediate image while allowing more flexibility in extracting internal object structures. The second stage makes use of an empirical Bayesian/random effects model that enables an optimal determination of the weighting parameter of the penalized term. The new approach demonstrates quantifiably improved images in simulation, phantom and in vivo experiments with particularly striking improvements with respect to the recovery of heterogeneities internal to large, high contrast scatterers such as encountered when imaging the human breast in a water-coupled configuration.

Algorithms↗

Quantitative hemoglobin tomography with diffuse near-infrared spectroscopy: pilot results in the breast.

The authors describe what is, to the best of their knowledge, the first quantitative hemoglobin concentration images of the female breast that were formed with model-based reconstruction of near-infrared intensity-modulated tomographic data. The results in 11 patients, including two with breast tumors with pathologic correlation, are summarized. Hemoglobin concentration appears to correlate with tumor vascularity without the need for exogenous contrast material and thereby has intrinsic diagnostic value.

Adult↗

Estimation of oxygen distribution in RIF-1 tumors by diffusion model-based interpretation of pimonidazole hypoxia and eppendorf measurements.

Numerical simulations of oxygen diffusion from the capillaries in tumor tissue were used to predict the capillary oxygen supply within and near hypoxic regions of the RIF-1 tumor. A finite element method to simulate the oxygen distribution from a histology section is presented, along with a method to iteratively estimate capillary oxygen concentrations. Pathological structural data for these simulations came from sections of the tumor stained with hematoxylin and eosin and were used to define the capillary positions and shapes, while overlapping regions of low oxygen concentration were defined by the hypoxia marker pimonidazole. These simulations were used to calculate spatial maps of the oxygen concentration and were tested for their ability to reproduce Eppendorf pO(2) histograms from the same tumor line. This simulation study predicted that capillary oxygen concentrations ranged from zero to above 20 microM, with a dominant peak in the hypoxic regions showing 78% of capillaries with less than 1 microM oxygen concentration, compared to only 12% in the non-hypoxic regions. The results were not highly sensitive to the metabolic oxygen consumption rate, within the range of 2 to 16 microM/s. This numerical method for oxygen capillary simulation is readily adaptable to histology sections and provides a method to examine the heterogeneity of oxygen within the capillaries and throughout the tumor tissue section being examined.

Animals↗

Electrical impedance imaging at multiple frequencies in phantoms.

We have recently built and tested a 32 channel, multi-frequency (1 kHz to 1 MHz) voltage mode system to investigate electrical impedance spectroscopy (EIS) imaging. We completed a series of phantom experiments to define the baseline imaging performance of our system. Our phantom consisted of a plastic circular tank (20 cm diameter) filled with 0.9% aqueous NaCl solution. Conductors and nonconductors of decreasing width (W5: 3.4 cm, W4: 2.54 cm, W3: 0.95 cm, W2: 0.64 cm and WI: 0.32 cm) were positioned at various distances from the tank edge (1 cm, 2 cm, 4 cm and 8 cm). The results suggest that the detection of objects less than 1 cm in width is limited to the first 1 to 2 cm from the tank edge for absolute images, but this depth can extend to 8 cm in difference images. Larger 3.4 cm wide objects can be detected in absolute images at depths up to 8 cm from the tank edge. Generally, conductor images were clearer than their nonconductor counterparts. Not only did electrode artefacts lessen as the frequency increased, but the system's maximum resolution was attained at the highest operating frequencies. Although the system recovered the value of the electrical conductivity at the correct order of magnitude, it tended to smooth out large property discontinuities. The calculated electrical permittivity in these phantom studies was inconclusive due to the presence of electrode artefacts.

Electric Impedance↗

Multifrequency electrical impedance imaging: preliminary in vivo experience in breast.

We have deployed a recently completed spectroscopic electrical impedance tomography (EITS) imaging system in a small series of women (13 participants accrued to date) in order to investigate the feasibility of delivering EITS breast examinations on a routine basis. Hardware is driven with sinusoidally varying spatial patterns of applied voltage delivered to 16 electrodes over the 10 kHz to 1 MHz spectral range using a radially translating interface which couples the electrodes to the breast through direct contact. Imaging examinations have consisted of the acquisition of multi-channel measurements at ten frequencies on both breasts. Participants lie prone on an examination table with the breast to be imaged pendant in the electrode array that is located below the table. Examinations were comfortable and easy to deliver (about 10 minutes per breast including electrode-positioning time). Although localized near-surface electrode artefacts are evident in the acquired images, several findings have emerged. Permittivity images have generally been more informative than their conductivity counterparts, except in the case of fluid-filled cysts. Specifically, the mammographically normal breast appears to have characteristic absolute EITS permittivity and conductivity images that emerge across subjects. Structural features in the EITS images have correlated with limited clinical information available on participants with benign and malignant abnormality, cysts and scarring from previous lumpectomy and follow-up radiation therapy. Several cases from this preliminary experience are described.

Breast↗

A multichannel continuously selectable multifrequency electrical impedance spectroscopy measurement system.

There is increasing evidence that alterations in the electrical property spectrum of tissues below 10 MHz is diagnostic for tissue pathology and/or pathophysiology. Yet, the complexity associated with constructing a high-fidelity multichannel, multifrequency data acquisition instrument has limited widespread development of spectroscopic electrical impedance imaging concepts. To contribute to the relatively sparse experience with multichannel spectroscopy systems this paper reports on the design, realization and evaluation of a prototype 32-channel instrument. The salient features of the system include a continuously selectable driving frequency up to 1 MHz, either voltage or current source modes of operation and simultaneous measurement of both voltage and current on each channel in either of these driving configurations. Comparisons of performance with recently reported fixed-frequency systems is favorable. Volts dc (VDC) signal-to-noise ratios of 75-80 dB are achieved and the noise floor for ac signals is near 100 dB below the signal strength of interest at 10 kHz and 60 dB down at 1 MHz. The added benefit of being able to record multispectral information on source and sense signal amplitudes and phases has also been realized. Phase-sensitive detection schemes and multiperiod undersampling techniques have been deployed to ensure measurement fidelity over the full bandwidth of system operation.

Calibration↗

In vivo quantification of a homogeneous brain deformation model for updating preoperative images during surgery.

Clinicians using image-guidance for neurosurgical procedures have recently recognized that intraoperative deformation from surgical loading can compromise the accuracy of patient registration in the operating room. While whole brain intraoperative imaging is conceptually appealing it presents significant practical limitations. Alternatively, a promising approach may be to combine incomplete intraoperatively acquired data with a computational model of brain deformation to update high resolution preoperative images during surgery. The success of such an approach is critically dependent on identifying a valid model of brain deformation physics. Towards this end, we evaluate a three-dimensional finite element consolidation theory model for predicting brain deformation in vivo through a series of controlled repeat-experiments. This database is used to construct an interstitial pressure boundary condition calibration curve which is prospectively tested in a fourth validation experiment. The computational model is found to recover 75%-85% of brain motion occurring under loads comparable to clinical conditions. Additionally, the updating of preoperative images using the model calculations is presented and demonstrates that model-updated image-guided neurosurgery may be a viable option for addressing registration errors related to intraoperative tissue motion.

Animals↗

In vivo modeling of interstitial pressure in the brain under surgical load using finite elements.

Current brain deformation models have predominantly reflected solid constitutive relationships generated from empirical ex vivo data and have largely overlooked interstitial hydrodynamic effects. In the context of a technique to update images intraoperatively for image-guided neuronavigation, we have developed and quantified the deformation characteristics of a three-dimensional porous media finite element model of brain deformation in vivo. Results have demonstrated at least 75-85 percent predictive capability, but have also indicated that interstitial hydrodynamics are important. In this paper we investigate interstitial pressure transient behavior in brain tissue when subjected to an acute surgical load consistent with neurosurgical events. Data are presented from three in vivo porcine experiments where subsurface tissue deformation and interhemispheric pressure gradients were measured under conditions of an applied mechanical deformation and then compared to calculations with our three-dimensional brain model. Results demonstrate that porous-media consolidation captures the hydraulic behavior of brain tissue subjected to comparable surgical loads and that the experimental protocol causes minimal trauma to porcine brain tissue. Working values for hydraulic conductivity of white and gray matter are also reported and an assessment of transient pressure gradient effects with respect to deformation is provided.

Animals↗

Calibration of near-infrared frequency-domain tissue spectroscopy for absolute absorption coefficient quantitation in neonatal head-simulating phantoms.

Frequency-domain tissue spectroscopy is a method to measure the absolute absorption coefficient of bulk tissues, assuming that a representative model can be found to recover the optical properties from measurements. While reliable methods exist to calculate absorption coefficients from source-detector measurements less than a few centimeters apart along a flat tissue volume, it is less obvious what methods can be used for transmittance through the larger tissue volumes typically associated with neonatal cerebral monitoring. In this study we compare the use of multiple distance frequency-domain measurements processed with (i) a modified Beer-Lambert law method, (ii) an analytic infinite-medium diffusion theory expression, and (iii) a numerical finite element solution of the diffusion equation, with the goal of recovering the absolute absorption coefficient of the medium. Based upon our observations, the modified Beer-Lambert method provides accurate absolute changes in the absorption coefficient, while analytic infinite-medium diffusion theory solutions or finite element-based numerical solutions can be used to calculate the absolute absorption coefficient, assuming that the data can be measured at multiple source-detector distances. We recommend that the infinite-medium multi-distance method or the finite element method be used across large tissue regions for calculation of the absolute absorption coefficient using frequency-domain near-infrared measurements at multiple positions along the head.

Absorption↗

Contrast-detail analysis for detection and characterization with near-infrared diffuse tomography.

Near-infrared (NIR) diffuse tomography is emerging as a medical imaging modality for obtaining information related to tissue hemoglobin concentration and oxygen saturation and may be used for characterizing diseased tissues such as breast cancer. The optimal methodology for NIR image reconstruction remains an ongoing research problem with several new approaches being demonstrated in recent years. However, a comparison of reconstruction methods is problematic because tools for the objective assessment of image quality have yet to be clearly defined for this type of nonlinear reconstruction problem. Contrast-detail analysis has become an accepted assessment tool to quantify x-ray mammography image quality, and in this study it has been applied to a prototype NIR diffuse tomography system that is being evaluated for breast cancer characterization. The minimum detectable levels of contrast have been defined for different sizes of objects, and the minimum contrasts which can be accurately reconstructed have also been determined for the same object sizes. In general, objects 8 mm and larger in diameter can be accurately reconstructed and detected for most absorption contrasts which are observed in human tissues (i.e., greater than 1% contrast in absorption). Objects as small as 2 mm can be detected with high contrast (i.e., near 100%), but cannot be accurately reconstructed. Within the size range of 2 mm to 8 mm, there is an inverse correlation between contrast and detail size which is characteristic of the total noise in the system. This analysis provides an objective method for assessing detection and characterization limits and can be applied to future improvements in hardware system architecture as well as reconstruction algorithms.

Algorithms↗

Elasticity reconstruction from experimental MR displacement data: initial experience with an overlapping subzone finite element inversion process.

The determination of the elastic property distribution in heterogeneous gel samples with a finite element based reconstruction scheme is considered. The algorithm operates on small overlapping subzones of the total field to allow for a high degree of spatial discretization while maintaining computational tractability. By including a Maxwellian-type viscoelastic property in the model physics and optimizing the spatial distribution of this property in the same manner as elasticity, a Young's modulus image is obtained which reasonably reflects the true distribution within the gel. However, the image lacks the clarity and accuracy expected based on simulation experience. Preliminary investigations suggest that transient effects in the data are the cause of a significant mismatch between the inversion model, which assumes steady-state conditions, and the actual displacements as measured by a phase contrast MR technique.

Algorithms↗

Application of linear circuit models to impedance spectra in irradiated muscle.

We have applied a number of modeling schemes to previously reported in vivo electrical impedance measurements on irradiated and normal muscle in the hind legs of rats. Specifically, seven-parameter parallel pathways and embedded membrane circuit models have been fit to group averages of impedance spectra measured at different doses and time points. Correlations between histologically scored tissue sections and model parameters have also been determined. The results show that both models produce good fits to the experimental observations, especially in the case of the irradiated tissues. The correlations between histology scores and circuit parameters were, however, higher with the embedded model. Trends in the spectra and the model parameters were found to agree with the expected changes in tissue pathophysiology associated with the progression of tissue injury from radiation exposure. Quantitative correlations with specific histological criteria were less conclusive, suggesting that more information may be needed to refine the model architecture if model parameters are to be explicitly related to the types and extent of tissue damage induced by radiation treatments.

Animals↗