Search PubMed⌕ Search

PubMed · 8024933

Nitrous oxide elimination.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Y Lin. 1994. Nitrous oxide elimination.. https://doi.org/10.1093/bja%2F72.6.729-a

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Sleeping position, oxygen saturation and lung volume in convalescent, prematurely born infants.

OBJECTIVE: To determine whether the effects of sleeping position on lung volume and oxygenation are influenced by postmenstrual age (PMA) and oxygen dependency in convalescent prematurely born infants. DESIGN: Prospective study. SETTING: Tertiary neonatal unit. PATIENTS: 41 infants (21 oxygen dependent), median gestational age 28 weeks (range 24-31 weeks) and birth weight 1120 g (range 556-1780 g). INTERVENTION: Infants were studied both supine and prone at two-weekly intervals from 32 weeks' PMA until discharge. Each posture was maintained for 1 h. MAIN OUTCOME MEASURES: Pulse oximeter oxygen saturation (Spo(2)) was monitored continuously, and at the end of each hourly period functional residual capacity (FRC) was measured. RESULTS: Overall, lung volumes were higher in the prone position throughout the study period; there was no significant effect of PMA on lung volumes. Overall, Spo(2) was higher in the prone position (p = 0.02), and the effect was significant in the oxygen-dependent infants (p = 0.03) (mean difference in Spo(2) between prone and supine was 1.02%, 95% CI 0.11% to 1.92%), but not in the non-oxygen-dependent infants. There was no significant influence of PMA on Spo(2). CONCLUSION: In the present study, prone sleeping did not improve oxygenation in prematurely born infants, 32 weeks' PMA or older and with no ongoing respiratory problems. However, the infants were monitored in each position for an hour, thus it is recommended that oxygen saturation should continue to be monitored after 32 weeks' PMA to be certain that longer periods of supine sleeping are not associated with loss of lung volume and hypoxaemia.

Functional Residual Capacity↗

Problems in the measurement of functional residual capacity.

Accurate assessment of lung volume in infancy is important to determine the impact of disease and the efficacy of therapies. A new generation of infant plethysmographs with lower apparatus deadspace has been produced, but gives lower volume results than those from older traditional plethysmographs. We hypothesized that the new plethysmographs might have greater sensitivity to the adiabatic effect and hence they, rather than the traditional plethysmographs, produced erroneous results. Our aim was to assess the influence of the adiabatic effect on the results of a contemporary plethysmograph, an older traditional plethysmograph and a helium gas dilution system using a lung model. Altering the amount of copper wool within the lung model allowed the influence of the adiabatic effect on the plethysmographic results to be assessed. The measured compared to the actual volumes were significantly lower for the contemporary plethysmograph compared to the traditional plethysmograph (p < 0.001) and to the helium gas dilution system (p < 0.001). Under optimal testing conditions the contemporary plethysmograph under-recorded by 11-13%, whereas the other two systems gave similar results to the actual volumes. As the effect of the adiabatic effect was increased, the discrepancy between the results of the contemporary and the traditional plethysmographs increased. We conclude, the contemporary plethysmograph is more sensitive to adiabatic effects and hence under-records.

Functional Residual Capacity↗