[Considerations for optimizing joint implants].

Abstract

Despite the increasing use of orthopaedic implants, there is still a lack of adequate testing procedures and legal guidelines. Examples of the consequences of this neglect are given. Modern techniques for the calculation of stresses (finite element method [FEM]) and the prediction of life cycle duration are presented. Such methods, applied in the development and manufacturing phases of standard and special implants, may ensure an adequate prosthetic life cycle, with particular emphasis being placed on the biomedical optimization of the implant/bone interface and surrounding bone.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H M Tensi, S Orloff, H Gese, H Hooputra. 1994. [Considerations for optimizing joint implants].. https://doi.org/10.1515/bmte.1994.39.9.227

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effects of muscle dysfunction on lumbar spine mechanics. A finite element study based on a two motion segments model.

STUDY DESIGN: A combined finite element and optimization approach was developed to investigate the clinically relevant biomechanical parameters of the muscular lumbar spine under five quasistatic back-lifting conditions. OBJECTIVES: To quantify the effects of muscle "dysfunction" on the mechanical behavior of the lumbar spine. SUMMARY OF BACKGROUND DATA: Trunk muscles have been proven to play an important role in the normal functioning of the spine. Although passive structures of the spine are believed to be subjected increasingly to mechanical stresses when muscular support is inadequate, supportive quantitative data have been lacking. METHODS: External loads at L3-L4 for various lifting tasks were estimated experimentally and partitioned to the disc and muscles across the L3-L4 segment using an optimization scheme. These forces were incorporated into a finite element model of the ligamentous L3-L5 lumbar spine. Muscle "dysfunction" was simulated by decreasing the computed muscle forces. RESULTS: The range of motion intradiscal pressure forces in ligaments, and load across facets increased nonlinearly with the increases in trunk flexion and the load held in hands. At higher loads or at larger flexed postures, muscles were found to play a more crucial role in stabilizing the spine compared with the passive structures. Muscle "dysfunction" destabilized the spine, reduced the role of facet joints in transmitting load, and shifted loads to the discs and ligaments. CONCLUSIONS: Muscle dysfunction disturbs the normal functioning of other spinal components and may cause spinal disorders.

Biomechanical Phenomena

Can variations in intervertebral disc height affect the mechanical function of the disc?

STUDY DESIGN: The finite element method was used to investigate the effect of variations in disc height on the mechanical behavior of the intervertebral disc. OBJECTIVES: The effect of disc height on the mechanical behavior of a human lumbar spine segment in terms of axial displacement, intradiscal pressure, posterolateral disc bulge, tensile stress in the peripheral anulus fibers, and longitudinal stress distribution at the end plate-vertebra interface was evaluated. SUMMARY OF BACKGROUND DATA: Disc height varies with individuals, disc level, abnormal conditions, and clinical management. METHODS: A three-dimensional finite element model of L2-L3 disc body unit was developed. Parametric studies were undertaken by studying discs of three different heights: 8 mm, 10 mm, and 12 mm, whereas disc cross sectional area, finite element mesh density, and all other parameters were kept constant. The model accounted for geometric nonlinearity but assumed that the material properties were linear. RESULTS: Variations in disc height had a significant influence on the axial displacement, the posterolateral disc bulge, and the tensile stress in the peripheral anulus fibers, but the effect on the intradiscal pressure and the longitudinal stress distribution at the endplate vertebra interface was minimal. CONCLUSIONS: Variations in disc height may compromise the general conclusions reached from experimental work and analytic studies in which geometric parameters (especially disc height and disc cross-sectional area) are not taken into consideration.

Biomechanical Phenomena