Search PubMedSearch

PubMed · 7897843

[Body surface potential mapping system].

Abstract

Body surface potential mapping systems have been developed by several laboratories in our country as well as many other countries all over the world. In most laboratories the basic procedure is the same. Body surface potentials are measured simultaneously using a multiplexer with or without sampling bold, with Wilson's central terminal and stored on a floppy disk in a digital form. Editing for waveform and drift of the baseline was performed in each leads and invalid leads were interpolated from surrounding leads values. Then, different types of maps such as isopotential map, isointegral map, isochronal map and departure map suitable for each clinical evaluation are constructed automatically. However, although body surface mapping provides detailed information about cardiac electrical activity, its clinical use has been limited by the following reasons summarized by B. Taccardi in 1985. 1) Lack of standardization: Different electrode replacement prevents comparing the results. 2) The equipment is comparably expensive. 3) Application of electrode is time-consuming. 4) Analysis of data is not standardized. Further clinical studies may improve some of above described difficulties. And the availability of high performance microcomputers and clinically acceptable electrodes are essential.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Tsunakawa, G Nishiyama. 1995. [Body surface potential mapping system].. https://pubmed.ncbi.nlm.nih.gov/7897843/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Spatial features in body-surface potential maps can identify patients with a history of sustained ventricular tachycardia.

BACKGROUND: Regional disparities of ventricular primary-repolarization properties contribute to an electrophysiological substrate for arrhythmias. Such disparities can be assessed from body-surface distributions of ECG QRST areas. Our objective was to isolate and test those features of QRST-area distributions that would be suitable for identifying patients at risk for life-threatening ventricular arrhythmias. METHODS AND RESULTS: We recorded ECGs simultaneously from 120 leads during sinus rhythm for 204 patients taking no antiarrhythmic drugs: half had had sustained ventricular tachycardia (VT); the other half, a myocardial infarction but no history of VT. For each patient, we calculated the QRST area in each lead and, using Karhunen-Loeve (K-L) expansion, reduced these data to 16 coefficients (each relating to one spatial feature, an eigenvector, derived from the total set of 204 QRST-area maps). Using stepwise discriminant analysis, we selected feature subsets that best discriminated between the two groups, and we estimated by a bootstrap procedure using 1000 trials how these subsets would perform on a prospective patient population. The mean diagnostic performance of the classifier for 1000 randomly selected training sets (n = 102 in each, with both groups equally represented) increased monotonically with the number of features used for classification. The initial trend for the corresponding test sets (n = 102 in each) was the same but reversed when the number of features exceeded eight. For an optimal set of eight spatial features, the sensitivity and specificity of the classifier for detecting patients with VT in 1000 test sets were (mean +/- SD) 90.3 +/- 4.3% and 78.0 +/- 6.1%, and its positive and negative predictive accuracies were 80.7 +/- 4.2% and 89.2 +/- 4.2%, respectively. Use of QRS duration as a supplementary feature to eight K-L coefficients can, in the test sets, increase specificity to 80.9 +/- 5.4% and positive predictive accuracy to 82.8 +/- 3.9% compared with the results for the optimal number of eight K-L features alone. CONCLUSIONS: Multiple body-surface ECGs contain valuable spatial features that can identify the presence of an arrhythmogenic substrate in the myocardium of patients at risk for ventricular arrhythmias. Our results compare very favorably with those achieved by any other known test, invasive or noninvasive, for arrhythmogenicity.

Body Surface Potential Mapping

QRST isointegral map reflects the sudden reduction of right ventricular pressure after balloon pulmonary valvuloplasty.

To elucidate the mechanism of electrocardiographic changes due to right ventricular pressure overload, serial changes on body surface maps recorded in two children with valvular pulmonary stenosis before and after successful reduction of right ventricular pressure by balloon valvuloplasty (BVP) were studied. Body surface maps and 12-lead electrocardiograms were simultaneously recorded before and 1-1.5 hours, 8 hours, and 5 days after BVP. Before BVP, QRST isointegral maps showed either two maxima or an expanded single maximum on the right anterior chest. These abnormal characteristics become normal or near normal 1-1.5 hours after BVP. Electrocardiographic waveforms and QRS and ST-T isointegral maps showed minimal changes. Changes in QRST isointegral maps were observed near the center of the midanterior chest. These results suggest that increased right ventricular pressure caused a primary repolarization abnormality in the mid-anterior chest that was easily detected by body surface QRST isointegral maps.

Body Surface Potential Mapping

An equivalent body surface charge model representing three-dimensional bioelectrical activity.

A new surface-source model has been developed to account for the bioelectrical potential on the body surface. A single-layer surface-charge model on the body surface has been developed to equivalently represent bioelectrical sources inside the body. The boundary conditions on the body surface are discussed in relation to the surface-charge in a half-space conductive medium. The equivalent body surface-charge is shown to be proportional to the normal component of the electric field on the body surface just outside the body. The spatial resolution of the equivalent surface-charge distribution appears intermediate between those of the body surface potential distribution and the body surface Laplacian distribution. An analytic relationship between the equivalent surface-charge and the surface Laplacian of the potential was found for a half-space conductive medium. The effects of finite spatial sampling and noise on the reconstruction of the equivalent surface-charge were evaluated by computer simulations. It was found through computer simulations that the reconstruction of the equivalent body surface-charge from the body surface Laplacian distribution is very stable against noise and finite spatial sampling. The present results suggest that the equivalent body surface-charge model may provide an additional insight to our understanding of bioelectric phenomena.

Body Surface Potential Mapping