Search PubMed⌕ Search

PubMed · 7783307

NIH consensus conference: Total hip replacement. NIH Consensus Development Panel on Total Hip Replacement.

Abstract

OBJECTIVE: To provide physicians with a current consensus on total hip replacement. PARTICIPANTS: A nonfederal, nonadvocate, 13-member consensus panel representing the fields of orthopedic surgery, rehabilitation and physical medicine, biomechanics and biomaterials, internal medicine, public health, geriatrics, biostatistics, and a public representative. In addition, 27 experts in orthopedic surgery, rehabilitation and physical medicine, biomechanics and biomaterials, rheumatology, geriatrics, and epidemiology presented data to the consensus panel and a conference audience of 425. EVIDENCE: The literature was searched through MEDLINE and an extensive bibliography of references was provided to the panel and the conference audience. Experts prepared abstracts with relevant citations from the literature. Scientific evidence was given precedence over clinical anecdotal experience. CONSENSUS: The panel, answering predefined consensus questions, developed their conclusions based on the scientific evidence presented in open forum and the scientific literature. CONSENSUS STATEMENT: The panel composed a draft statement that was read in its entirety and circulated to the experts and the audience for comment. Thereafter, the panel resolved conflicting recommendations and released a revised statement at the end of the conference. The panel finalized the revisions within a few weeks after the conference. CONCLUSIONS: Total hip replacement is an option for nearly all patients with diseases of the hip that cause chronic discomfort and significant functional impairment. Most patients have an excellent prognosis for long-term improvement in symptoms and physical function. At this time, a cemented femoral component using modern cementing techniques, paired with a porous-coated acetabular component, can give excellent long-term results. Revision of a total hip replacement is indicated when mechanical failure occurs. Continued periodic follow-up is necessary to identify early evidence of impending failure so as to permit remedial action before a catastrophic event.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

1995-06-28. NIH consensus conference: Total hip replacement. NIH Consensus Development Panel on Total Hip Replacement.. https://pubmed.ncbi.nlm.nih.gov/7783307/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The use of megavoltage cone-beam CT to complement CT for target definition in pelvic radiotherapy in the presence of hip replacement.

In Europe and the USA combined, over half a million people had a hip joint replaced in 2005, contributing to the increasing number of radiotherapy patients with metallic hip prostheses. The treatment plan for external beam radiation therapy is based on the delineation of the anatomy in the planning CT scan. When implanted objects of high atomic number (Z) material are present, however, severe image artefacts are generated in conventional CT, strongly hindering the ability to delineate some organs. This is particularly the case for the planning of prostate patients with hip prostheses. This short communication presents the use of a new imaging modality, megavoltage cone-beam CT, to complement the regular CT for target definition of prostate cancer treatment of patients with hip replacements.

Hip Prosthesis↗

Stem damage during implantation of modular hip prostheses.

Modular hip prostheses are commonly used today. Dedicated surgical auxiliary instrumentation is indispensable. A correct coupling between the prosthesis and the instrument is necessary to avoid damage. Based on a specific commercial design (AnCAFit, Wright Cremascoli Ortho, Toulon, France), the aim of this work was to assess if stem holders of modular prostheses can induce any stem damage, and if so, to identify the features that provide minimal damage. Two different stem holder connector designs were investigated. The surface of the stem cavity was inspected to identify the damage caused by the use of the two connectors after a simulated surgical handling. Both connectors induced some damage, with significantly more damage being caused by a supposedly improved design. Scars due to contact with the stem holder were observed on the stem cavity surface. This may be sufficient to trigger increased fretting damage during service life, causing the production of fretting debris.

Hip Prosthesis↗