Search PubMed⌕ Search

PubMed · 7770994

[The "inserted" condylar plate].

Abstract

Twelve extensive segmental and comminuted fractures of the femur affecting the metaphyseal areas (7 times proximal, 5 times distal) and the diaphysis were treated with extremely long condylar plates (16 to 20 holes). The condylar plates were inserted via a proximal and a distal incision leaving the Musculus vastus lateralis intact at the fracture site in all cases. Following standard preparation of the blade position using the seating chisel, the condylar plate was inserted behind the musculus vastus lateralis with the blade pointing towards the surgeon. The condyles or the trochanteric area were tilted slightly and the plate was turned 180 degrees and driven home. No screws were inserted in the area of the fracture, in particular, lag screws were not used. Ten out of 12 fractures healed without problems, in 2 cases bone grafting was necessary. Three main observations resulted from analysis of the operations and subsequent clinical and radiographical assessments. In the presence of relatively intact soft tissue covering, an astonishingly good reduction of the fragments was achieved after restoration of leg length and extension. In the healing process, callus formed rapidly and provided medial support. The bone structure was found to be more homogeneous than in the case for plate fixation involving several screws at the fracture site around which considerable fluctuations in bone density frequently occur. The application of condylar plates behind the musculus vastus lateralis by only proximal and distal incision for osteosyntheses of extensive multifragmental fractures is a further development of bridge-plating and can be recommended for long fractures.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Wenda, M Runkel, L Rudig. 1995. [The "inserted" condylar plate].. https://doi.org/10.1007/bf02588734

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Stacked plating for metadiaphyseal fractures of the distal radius: a technique report.

Combined injuries of the distal radius and shaft are rare, are usually caused by high energy, and pose a surgical dilemma. Surgical tactics and implants that are routinely used either for isolated fractures of the distal radius or for fractures of the radial shaft are often not applicable for this combined injury. We describe a technique of dual-stacked plating for these metadiaphyseal fractures and its use in two patients.

Bone Plates↗

Plate fixation of olecranon osteotomies.

The management of intra-articular distal humeral fractures remains a difficult surgical problem. Although an olecranon osteotomy provides excellent exposure for management of these fractures, a number of complications can occur after the creation and repair of the osteotomy including nonunion, malunion, hardware failure, and pain secondary to prominent hardware. In an effort to reduce the incidence of these complications, the senior authors now use contoured 3.5 mm reconstruction plates for the fixation of their apex-distal chevron olecranon osteotomies. Two surgeons at a single institution used this technique of exposure on a series of 17 consecutive patients with intra-articular distal humerus fractures between 1996 and 1999. In this series, all osteotomies united. There was one complication related specifically to the osteotomy: one of the screws in the plate penetrated the proximal radioulnar joint, interfering with forearm rotation; a second procedure was required to shorten the screw. Only one of the 17 patients requested plate removal during the 32 month (average) follow-up period. Plate fixation of olecranon osteotomies using a 3.5 mm reconstruction plate provides a construct with predictable healing and few complications. The overall results using this technique are comparable with other reported methods in the literature.

Bone Plates↗