Search PubMedSearch

PubMed · 7749004

Simple method for platelet counting.

Abstract

A method is proposed for counting the number of adhered platelets based on the determination of lactate dehydrogenase activity in bulk after lysis of adhered platelets. This method was compared with the widely used radioisotope labelling technique. It was concluded that the present lactate dehydrogenase method is effective in counting the adhered platelets, as no significant difference was found between the readings of two methods when commercial polymers and glass were used as samples.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y Tamada, E A Kulik, Y Ikada. 1995. Simple method for platelet counting.. https://doi.org/10.1016/0142-9612(95)92126-q

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Radiation dose perturbation at tissue-titanium dental interfaces in head and neck cancer patients.

PURPOSE: To determine the dose perturbation effects at the tissue-metal implant interfaces in head and neck cancer patients treated with 6 MV and 10 MV photon beams. METHODS AND MATERIALS: Phantom measurements were performed to investigate the magnitude of dose perturbation to the tissue adjacent to the titanium alloy implants with (100 mu and 500 mu thick) and without hydroxylapatite (HA) coating. Radiographic and radiochromic films were placed at the upper (and lower) surface of circular metal discs (diameter x thickness: 15 x 3.2, 48 x 3.2, 48 x 3.8 mm2) in a solid water phantom and were exposed perpendicular to radiation beams. The dosimeters were scanned with automatic film scanners. Using a thin-window parallel-plate ion chamber, dose perturbation were measured for a 48 x 3.2 mm2 disc. RESULTS: At the upper surface of the tissue-dental implant interface, the radiographic data indicate that for 15 x 3.2 mm2 uncoated, as well as 100 mu coated discs, dose perturbation is about +22.5% and +20.0% using 6 MV and 10 MV photon beams, respectively. For 48 x 3.2 mm2 discs, these values basically remain the same. However, for 48 x 3.8 mm2 discs, these values increase slightly to about +23.0% and +20.5% for 6 MV and 10 MV beams, respectively. For 48 x 3.2 mm2 discs with 500 mu coating, dose enhancement is slightly lower than that obtained for uncoated and 100 mu coated discs for each beam energy studied. At the lower interface for 15 x 3.2 mm2 and 48 x 3.2 mm2 uncoated and 100 mu coated discs, dose reduction is similar and is about -13.5% and -9.5% for 6 MV and 10 MV beams, respectively. For 48 x 3.8 mm2 discs, dose reduction is about -14.5% and -10.0% for 6 MV and 10 MV beams, respectively. For 48 x 3.2 mm2 discs with 500 mu coating, the dose reduction were slightly higher than those for uncoated and 100 mu coated discs. CONCLUSIONS: For the beam energies studied, dose enhancement is slightly larger for the lower energy beam. The results of dose perturbation were similar for 100 mu coated and uncoated discs. These results were slightly lower for the 500 mu coated discs but are not clinically significant. The dosimetry results obtained from radiochromic films were similar to the ones obtained from radiographic film. The dose enhancement results obtained from ion chamber dosimetry are higher than those obtained from film dosimetry. The ion chamber data represent the data at "true" tissue-titanium interface, whereas the ones obtained from film dosimetry represent the data at film-titanium interface.

Biocompatible Materials

Differential effects of different forms of hydroxyapatite and hydroxyapatite/tricalcium phosphate particulates on human monocyte/macrophages in vitro.

A possible complication associated with the use of hydroxyapatite (HA) or HA/tricalcium phosphate (HA/TCP) coating on the surfaces of prosthetic devices used for dental and orthopedic implants is their potential to fragment and thus exist as wear debris. In contrast to the so-called osteoconductive properties of HA or HA/TCP coatings, in particulate form these materials may lead to an adverse pattern of cellular and tissue responses at the bone-implant interface. We have established an in vitro cell culture system to characterize the biologic and biochemical effects of various particulate materials. The present study demonstrates that the HA/TCP particles derived from different sintering temperatures exhibit differential effects on cultured human monocyte/macrophages (M/M). The HA/TCP particles dried at 110 degrees C were the most biologically active, stimulating significant release of interleukin 1 beta (IL-1 beta), IL-6, tumor necrosis factor alpha, and prostaglandin E2 (PGE2), products implicated as important mediators of inflammation in diverse pathologic conditions. Other particles, sintered at either 900 or 1200 degrees C, did not stimulate production of cytokines or PGE2. HA/TCP particles from plasma-spray coatings also failed to release proinflammatory products. These results suggest that the biochemical and crystalline structural properties of particles markedly affects their capacity to modulate M/M function. This in vitro culture system should be useful in characterizing the specific physical and chemical properties of HA or HA/TCP particulates that are responsible for stimulating proinflammatory cell responses.

Biocompatible Materials

Hydroxyapatite/metal composite coatings formed by electrocodeposition.

Early bone infusion by cementless fixation of composite orthopedic and dental implants consisting of metallic substrates and bioceramics is well documented. Calcium phosphate ceramics in general and hydroxyapatite (HA) in particular have been the most popular of the bioceramics used for coating metals. Here, a non-line of sight coating procedure by electrocodeposition is reported for mechanically fixing HA particles in a metal matrix. Analyses of the coating showed excellent adhesion to the substrate and no structural transformation in either crystallinity or stoichiometry. Adhesion and surface coverage of HA depended upon the particle size. As a demonstration of the coating procedure's non-line of sight applicability, it was successfully used to coat titanium rods sintered with small titanium spheres.

Biocompatible Materials