Search PubMed⌕ Search

PubMed · 7355752

Ventricular compliance in ischemic right ventricular dysfunction.

Abstract

Ischemic right ventricular dysfunction was diagnosed in 54 patients with acute myocardial infarction who had a right atrial pressure disproportionately increased in relation to the pulmonary capillary pressure. The right atrial pressure curve in 40 patients (74 percent) was M- or W-shaped, termed a noncompliant pattern, and was similar to the pattern found in constrictive pericarditis. Kussmaul's sign was found in the patients whose respiration was recorded. This pattern, which represents poor right ventricular compliance, was severe in 30 cases (y descent greater than x descent) and slight in 10 cases (y descent = x descent). Its duration was variable, ranging from days to years. Of the 54 patients, 32 (59 percent) had a low output syndrome, diagnosed in the presence of a cardiac index of less than 2.2 liters/min per m2, with signs of poor tissue perfusion. The severe noncompliant pattern was significantly related to the presence of a low output syndrome (p less than 0.01) and mortality from this cause (p less than 0.05). The jugular venous tracing pulse had a pattern similar to that of the right atrial pressure recording and therefore may be valuable in the noninvasive diagnosis of right ventricular dysfunction and in the study of the evolution of the noncompliant pattern and, hence, of ventricular compliance.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

I Coma-Canella, J Lopez-Sendon. 1980. Ventricular compliance in ischemic right ventricular dysfunction.. https://doi.org/10.1016/s0002-9149(80)80004-x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗