Search PubMed⌕ Search

PubMed · 7154675

An automated microprocessor-controlled data collection device for use with the Technicon AutoAnalyzer system.

Abstract

An automated microprocessor-controlled data collection system for use with a Technicon AutoAnalyzer in a research or clinical laboratory is described. The collection system can digitize an analog output from the AutoAnalyzer, perform mathematical operations on this digital data, detect and record peak-trough data, and perform these data acquisition and mathematical data processing operations in parallel. The data collection system can be interfaced to a variety of host computers for further data analysis. The accuracy of the data collection system was tested and compared to existing procedures using an analysis of bovine serum albumin protein. The correlation coefficient for the comparison of the results was 0.99998. Hence, the automated system is as accurate as previous methods, but is considerably faster, more efficient, and, in comparison to existing devices, less expensive.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T P Moyles, D R Schneider, R F Erlandson. 1982. An automated microprocessor-controlled data collection device for use with the Technicon AutoAnalyzer system.. https://doi.org/10.1016/0160-5402(82)90076-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A user-friendly PC-based data acquisition and analysis system for respirometric investigations.

We have developed an easy-to-use computer-based system for recording, displaying, storing and analyzing signals generated by Clark-type oxygen electrodes. A user-friendly interface of Windows-based program BioMed significantly increases the productivity of investigations. It allows to process, control, present and archive the experimental data in real time. A 12-bit analog-to-digital-converter, analog and digital filters, a possibility to zoom the obtained respiratory curves and calculation of the respiration rates by a linear regression method increase the resolution of the estimated oxygen consumption rates. The new system enables to register even small changes, such as 3-5 ngatoms O/min, in respiration rates of biological objects -- enzymes, mitochondria and permeabilized muscle fibers. The system has been developed and is regularly used for the respirometric investigations at the Laboratory of Biochemistry, Institute for Biomedical Research, Kaunas University of Medicine.

Analog-Digital Conversion↗

Elimination of depth degeneracy in optical frequency-domain imaging through polarization-based optical demodulation.

A novel optical frequency-domain imaging system is demonstrated that employs a passive optical demodulation circuit and a chirped digital acquisition clock derived from a voltage-controlled oscillator. The demodulation circuit allows the separation of signals from positive and negative depths to better than 50 dB, thereby eliminating depth degeneracy and doubling the imaging depth range. Our system design is compatible with dual-balanced and polarization-diverse detection, important techniques in the practical biomedical application of optical frequency-domain imaging.

Analog-Digital Conversion↗