Search PubMed⌕ Search

PubMed · 7094444

Computer enhanced digital angiography.

Abstract

A new computer image enhancement technique was employed on cardiac images of 10 dogs and 7 patients to demonstrate the feasibility of an on-line automatic delineation of the left ventricular endocardial silhouette with a peripheral venous injection of contrast material while simultaneously reducing the x-ray dosage. This technique employs a very fast analog-to-digital conversion system capable of digitizing on-line video frames. By storing and continuously updating the first 30 video frames and then subtracting each incoming frame from this memory, most of the background is eliminated leaving only the contrast filled ventricle. Using calibrated densitometric measurements, we found that iodine concentrations in the human left ventricle following venous injection of 40 ml Renografin-76 (25 ml/s), peaked at 4.3 +/- 0.3 mg/ml (mean +/- SD) compared to 14.8 +/- 0.8 mg/ml following direct injection of 40 ml at 13 ml/s (p less than 0.001). The computer enhanced venous-injected images had an optical contrast 14 times greater than that of the unenhanced direct left ventriculogram. This increase in optical contrast provided unambiguous subjective definition of the endocardial borders. This technique is applicable to both central and peripheral contrast injection whereby high quality images can be obtained at approximately 98% reduction in radiation (5 mA, 65-85 kV), allowing performance of serial studies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Vas, G A Diamond, J A Levisman, F H Nakano, B S Neidorf, R M Rose, J S Whiting, J S Forrester. 1982. Computer enhanced digital angiography.. https://doi.org/10.1002/clc.4960050502

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Adequate left ventricular preparation allows for arterial switch despite late referral.

OBJECTIVE: To evaluate the feasibility of the arterial switch for surgical repair of transposition, defined as the combination of concordant atrioventricular and discordant ventriculo-arterial connections, after late referral. METHODS: From March 2000 to August 2001, six children underwent an arterial switch procedure following left ventricular preparation because of late referral. The mean age at referral was 8.3 months, with a range from 3 to 25 months, and mean body weight was 5.3 kg, with a range from 3.7 to 9.3 kg. The mean saturation of oxygen was 57%, with a range from 50 to 72%. Associated defects included a restrictive ventricular septal defect in three patients, aortic coarctation in one, and partially anomalous pulmonary venous connection in one. The mean interval between referral and the arterial switch procedure was 3.7 months, within a range from 1 to 7 months. A mean of 1.5 surgical procedures were undertaken to prepare the left ventricle, the most being 3 procedures, including combinations of creation of an inter-atrial communication in four patients, banding of the pulmonary trunk in five, and creation of a systemic-to-pulmonary arterial shunt in three. We evaluated left ventricle ejection and shortening fractions, left ventricular diastolic diameter and volume, right and left ventricular wall thicknesses, and the ratio of right to left ventricular values by echocardiography at referral, immediately before, and one week after the arterial switch procedure. RESULTS: All children are alive and well, with a mean follow-up of 17 months, ranging from 9 to 26 months. Echocardiography showed a statistically significant decrease of the ratio between right and left ventricular wall thicknesses, from 1.33 +/- 0.26 at referral to 0.79 +/- 0.08 before the switch procedure (p < 0.005). Left ventricular function was adequate after arterial switch, with a mean ejection fraction of 79.3%, ranging from 66 to 87%, and a mean shortening fraction of 41.7%, ranging from 30 to 49%. CONCLUSIONS: Despite late referral, and initially inadequate left ventricular volume and mural thickness, children with transposition can successfully be treated with the arterial switch procedure, provided that the left ventricle is adequately prepared, using echocardiography to monitor left ventricular morphology and function.

Angiocardiography↗

Ventriculography using ECG-gated multiple diastolic injection of contrast material in pediatric angiocardiography.

In pediatric patients, the lower body weight limits the volume of contrast medium. Conventionally, angiocardiography is carried out with a single large bolus injection of contrast material. Angiocardiograms are used in pediatric patients with complex congenital heart diseases. In patients with complex congenital heart disease, especially with MAPCA, the volume of contrast medium used may be excessive. This would allow further injection to provide additional information. To reduce contrast medium used in the angiocardiogram in pediatric patients, we decided to use electrocardiogram (ECG)-gated multiple diastolic injection (EMDI). Three small boluses were injected during the diastolic phase of three consecutive cardiac cycles using a commercially-available power injector. Seventy-eight ventriculograms (47 left ventriculograms and 31 right ventriculograms) using EMDI were carried out on 53 patients with congenital heart disease. Total contrast medium volume with EMDI ventriculograms (mean [+/- SD] per body weight: 0.72 [+/- 0.25] ml/kg) was significantly smaller than with conventional injection (1.01 [+/- 0.36] ml/kg) (p <0.001). The grades of ventriculograms with EMDI tended to be slightly better than those with conventional injection (statistically not significant, p = 0.478). No short-run type premature ventricular contraction (PVC)s or intramural injection occurred in the ventriculograms with EMDI. PVCs tended to be less frequent in the ventriculograms with EMDI than in those with conventional injection (statistically not significant, p = 0.131). EMDI may be worthwhile in reducing ventricular ectopy when checking ventricular function by angiography, since hemodynamic conditions are less affected by small quantities of contrast medium and only during the filling phase of the ventricles. In conclusion, EMDI may be a useful method for reducing complications of ventriculography in pediatric angiocardiography.

Angiocardiography↗

[Percutaneous balloon dilatation of discrete subaortic stenosis].

Discrete subaortic stenosis is an uncommon congenital cardiac disorder in which the left ventricular outflow tract is narrowed. We report about the diagnostic procedures and the successful balloon dilatation of a 49-year old, highly symptomatic male patient suffering from discrete subvalvular aortic stenosis.

Angiocardiography↗