Search PubMedSearch

PubMed · 6930604

Variables associated with electric pulp testing.

Abstract

A modern electronic pulp tester is evaluated in both the laboratory and clinical situations. Different electrode media are tested and compared to results obtained without any electrode media. Contact pads are also evaluated and found to add another variable to electric pulp testing. Several technique variables were introduced and found to have a significant effect on transmission of the stimulus to the tooth.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R L Cooley, S F Robison. 1980. Variables associated with electric pulp testing.. https://doi.org/10.1016/0030-4220(80)90334-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The choice of irrigant during hand instrumentation and ultrasonic irrigation of the root canal: a scanning electron microscope study.

The purpose of this study was to investigate the use of 4 per cent sodium hypochlorite and 15 per cent EDTAC, either alone or in conjunction, as irrigants during hand instrumentation and ultrasonic irrigation of the root canal. Thirty-six extracted human teeth, each with a single, straight root 21-25 mm long were hand-instrumented through a clinical access cavity to file size 40. One millilitre of the test irrigant was used after each instrument size. Canal debridement was completed with an intermittent flush irrigation technique with one or both of the test irrigants activated by ultrasound at a medium effective power output. The specimens were sectioned longitudinally, viewed in a scanning electron microscope and scored for the presence or absence of debris and smear layer at levels less than 1 mm, 5 mm, and 10 mm from the apical seat. Under the conditions of this experiment the most effective regime was irrigation with 1 mL EDTAC after each instrument size, followed by two 30 second exposures to ultrasound+EDTAC then four 30 second exposures to ultrasound + 4 per cent sodium hypochlorite. The specimens in this group were free from retained pulp tissue and superficial smear layer, had the lowest debris scores at the < 1 mm and 5 mm levels, and the lowest total debris score. All of the techniques tested produced smear-free canals at the 10 mm level.

Dental Pulp

Parvalbumin-like immunoreactivity in nerve fibres within human molar tooth pulps.

The root pulp contained two types of parvalbumin-immunoreactive nerve fibres, smooth and varicose. The smooth were relatively thick (mostly 3-5 microns in diameter) and sometimes had large swellings, whereas the varicose consisted of oval varicosities of 1-3 microns in long diameter with very fine strands interconnecting them. Most of the parvalbumin-immunoreactive root fibres were smooth, and the varicose were rare. Upon entering the pulp chamber, both types of fibre splayed out and ran towards the roof of the chamber and the pulp horn. In the subodontoblastic layer of the roof and horn, parvalbumin-immunoreactive fibres showed relatively straight chains of granules; they sent their granular terminals to the odontoblastic layer. Some parvalbumin-immunoreactive granules were observed in the predentine and some even in the dentine. The diameter of axons in the root pulp and the spatial distribution of terminals strongly suggest that the parvalbumin-immunoreactive fibres are mostly myelinated and sensory.

Dental Pulp

Efficacy of laser Doppler flowmetry in determining pulp vitality of human teeth.

The aim of this study was to examine if laser Doppler flowmetry (LDF) could aid in distinguishing teeth with necrotic pulps from vital teeth and if so, which configuration of 5 experimental probes would give the best results. Each probe had 3 fibers arranged in a triangle. One fiber carried the laser light to the pulp tissue and 2 fibers carried the back-scattered light to the detector giving the output signal. The distance between the 3 fibers in the triangular arrangement in each probe was 250, 500, 800, 1000, and 1500 microns. A special rubber-base splint was used to hold the probe in place on the buccal surface of the tested teeth. Eleven anterior teeth with clinically diagnosed necrotic pulp were measured with the LDF method and the results compared to contralateral teeth with vital pulp. For the sake of comparison, 10 pairs of anterior teeth with vital pulps in 10 patients were tested as well. The LDF signals were fed into an analog printer and a lap-top computer where all calculations were done. With the LDF method, the output signals from the teeth with necrotic pulps were significantly lower with all 5 probes than the output signals from the contralateral vital teeth. On average, the signal was 42.7% lower from the teeth with necrotic pulps than from the vital teeth. Four of 11 teeth with necrotic pulp gave a positive response to an electrical pulp tester (EPT). The results suggested that the probe with the smallest separation of fibers was the most sensitive in distinguishing necrotic pulps from vital ones.

Dental Pulp