Search PubMedSearch

PubMed · 6882161

Uncemented acetabular replacement.

Abstract

An uncemented Polyethylene acetabular component has been developed using a cup of conical outer configuration locked in position with the Freeman osseous peg. This cup is available in four sizes and is normally used with an uncemented femoral component. During the last 3 years 875 implants of this sort have been inserted and the results in these patients who are between 1 and 3 years post-operatively have been compared with the results in 236 replacements of a similar configuration but secured with bone cement in the usual way. The two groups have been demonstrated to be comparable in pre-operative diagnosis, age and sex. The results using the uncemented articulation are broadly the same as those using the cemented joint during the period of study but the acetabular component in 30% of the cemented joints showed a zone of demarcation between cement and bone whereas only one of the uncemented acetabular components showed similar radiological changes. The examination of the radiographs of the uncemented group suggests that the pelvic bone responds favourably to the stresses which are imposed upon it provided that the centre of the joint movement is relocated in the anatomical position, under these circumstances bone will usually build up to support the cup in a dysplastic acetabulum and in the floor of a central protrusion.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P A Ring. 1983. Uncemented acetabular replacement.. https://doi.org/10.1007/bf00379935

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Acetabular fractures: operative management and long term results.

INTRODUCTION: While the undisplaced acetabular fractures have a good prognosis after conservative treatment, the management of the displaced fractures has been a controversial issue over the last decades with variable results in their treatment and prognosis. Anatomical reduction can be only achieved operatively. The long term outcome of 209 patients with displaced acetabular fractures treated by open reduction and internal fixation was presented. MATERIAL AND METHODS: Between 1972 and 1996, 209 patients with a mean age of 38 years (15-62a) were treated for displaced acetabular fractures operatively. 161 patients could be followed up over a period of 2 to 20 years. The function of the hip joint in correlation with radiological results was evaluated according to the scheme of Merle d'Aubinge. RESULTS: Patients with single column fractures showed 90% good or excellent results followed by 55% good or excellent results in patients with transverse fractures. The highest rates of complication (20% osteoarthritis, 6% femoral head necrosis, 9% heterotopic ossification) were observed in both column fractures and in transverse and posterior wall fractures. Deep infection was observed in 6 cases (4%), superficial wound infection in 8 cases (5%). Primary sciatic nerve palsy was seen in 10 cases (6%) and postoperative peroneal nerve palsy in 6 cases (4%), all of which improved during the rehabilitation period. CONCLUSION: Displaced acetabular fractures of the weight bearing part of the dome, i.e. transtectal fractures, should be treated operatively. The operation should preferably be performed within one week after the injury.

Acetabulum

Effect of molecular weight, calcium stearate, and sterilization methods on the wear of ultra high molecular weight polyethylene acetabular cups in a hip joint simulator.

Orthopaedic surgeons must currently choose from several types of ultra high molecular weight polyethylene acetabular cups that differ in their material properties and in the methods used for their sterilization. Information on the wear resistance of these different cups may help in the selection process. This study included two separate tests for wear run on a hip simulator to investigate the effect of molecular weight, calcium stearate, and sterilization methods on the wear resistance of ultra high molecular weight polyethylene acetabular cups. Test 1 revealed nearly identical wear rates for acetabular cups with molecular weights in two distinct ranges, as well as for cups with molecular weights in the same range but with or without calcium stearate added. In Test 2, cups that were sterilized in air with gamma irradiation exhibited lower rates of wear than those sterilized with ethylene oxide, presumably due to the crosslinking induced by the irradiation. In addition, cups that were irradiated while packed in a partial vacuum to minimize oxygen absorbed in the surface layer initially showed lower rates of wear than those irradiated in air, with the wear rates becoming similar as wear penetrated the more oxidized surface layer and the more crosslinked subsurface region. Because these tests were run a few months after the irradiation, the potential effects of long-term oxidation of any residual free radicals in the irradiated materials could not be taken into account. After artificial aging to accelerate oxidative degradation of the materials, the wear rates could be markedly different. Analyses performed after wear indicated that the irradiated (i.e., crosslinked) cups exhibited a smaller proportion of, as well as shorter, fibrils in the wear debris and an increased crystallinity and melting temperature and that gamma irradiation in the low-oxygen environment reduced the level of oxidation and increased the level of crosslinking in the surface region of the cups.

Acetabulum

[The value of CT in classification and decision making in acetabulum fractures. A systematic analysis].

UNLABELLED: The classification of acetabular fractures and especially the diagnosis of additional lesions can be misleading, when the personal experience is limited and the decisions are based only on conventional radiographs. The introduction of Spiral-CT with multiplanar reformations and 3-D views has improved the quality of visualization. Due to their higher costs, the need of these additional diagnostic tools is frequently questioned. This paper discusses the relevance of plain radiographs, 2-D-CTs, 3-D-CTs and Femursubtraction-CTs (FsCT) for the classification of acetabular fractures, based on a controlled study. METHODS: Thirty physicians with different levels of experience in acetabular surgery were divided in three groups of 10 each: group I comprised residents without operative experience in acetabular surgery, group II was physicians with 3-10 years of operative experience, and group III was experts in acetabular surgery. A total of 10 complete radiographic cases of high quality providing all levels of preoperative diagnostics (plain radiographs, 2-D-CT, CT with multiplanar reformation, 3-D-CT, Fs-CT) of different acetabular fracture types were prepared. The task for each candidate was to classify the fracture according to Letournel and to identify all additional injuries within the hip joint (e.g. marginal impaction, head fractures, etc.). The different diagnostic "levels" could be ordered stepwise according to personal need and no time limit was given. The case was finished when the candidate presented his final diagnosis. The use of the different radiographs, the preliminary diagnosis, the changes in diagnosis, and the final decisions were recorded. These findings were correlated with the different levels of experience and against a "consensus classification" which was generated by thorough discussion, and the use of intraoperative information and postoperative radiographs not accessible to the candidates. RESULTS: The "correct" fracture classification based on plain radiographs was: group I, 11%; group II, 32%; group III, 61%. Based on 2-D-CT a "correct" diagnosis was reached by 30% in group I, by 55% in group II, and by 76% in group III. With consideration of the "transient forms" in acetabular fractures based on Letournel and the 3-D-CT used mainly by group I, the rate of "correct" classifications rose to 65% in group I, 64% in group II and 83% in group III. The modifiers were diagnosed "correctly" in group I by 37%, in group II by 56%, and in group III by 73%. The use of the 3-D-CT and especially the Fs-CT by group I resulted in an improvement in the rate of correct classifications to 61%, whereas in group II the Fs-Ct was used only exceptionally. The 2-D-CT was the basis for the diagnosis of the additional lesions in acetabular fractures within all groups resulting in 73% complete diagnoses in group III. This study showed the importance of CT for the exact analysis and classification of acetabular fractures. In particular, the secondary reformations in CT and the 3-D-views dramatically improved the rate of "correct" classifications in the group of surgeons with limited personal experience in acetabular surgery. This allows the less experienced an acceptable level of "correct" diagnoses, so that the treatment options can be weighed correctly. Among the "experts" a rate of divergent classifications of approximately 20% was observed, especially in "transient" forms of acetabular fractures.

Acetabulum