Search PubMedSearch

PubMed · 673363

[Materials for replacing bone defects and joining bones].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

O N Gudushauri, B L Solomianskiĭ, D A Omiadze. 1978. [Materials for replacing bone defects and joining bones].. https://pubmed.ncbi.nlm.nih.gov/673363/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of surface contamination on adhesive bonding of cast pure titanium and Ti-6Al-4V alloy.

STATEMENT OF PROBLEM: There is little information regarding bond strengths of resin cements to cast titanium surfaces contaminated by investment material. PURPOSE: This study examined the effect of surface contamination on the shear bond strength of resin cements to cast titanium and Ti-6Al-4V alloy. MATERIAL AND METHODS: Two types of disks were cast from commercially pure titanium (CP-Ti) and Ti-6Al-4V alloy ingots using an argon-arc pressure casting unit and a phosphate-bonded Al2 O3 /LiAlSiO6 investment. After casting, disks were subjected to 3 surface treatments: (1) cast surface sandblasted (50 microm-sized Al2 O3 ) for 30 seconds; (2) metal surface sanded with silicon-carbide paper (600 grit) after grinding the contaminated cast surface (approximately 200 microm in thickness); and (3) metal surface sandblasted for 30 seconds after treatment 2. Surface structures were examined after each treatment with SEM and optical microscopy. Each type of disk was then bonded with 2 types of luting materials. Bonded specimens were subjected to thermocycling for up to 50,000 cycles, and shear bond strengths were determined after 0 (baseline) and 50,000 thermocycles. Results were statistically analyzed with 3-way ANOVA (P <.05). RESULTS: Microscopic observation of cast CP-Ti and Ti-6Al-4V exhibited noticeable structures on the cast surfaces apparently contaminated with investment material. However, there were no statistical differences (P >.05) in the bond strengths of both cements between contaminated (treatment 1) and uncontaminated surfaces (treatment 3) for both metals at baseline and after 50,000 thermocycles. The bond strength of specimens sanded with silicon-carbide paper (treatment 2) deteriorated dramatically after 50,000 thermocycles. CONCLUSIONS: Contamination of the cast metal surfaces by elements of the investment during casting did not affect bond strengths of the luting materials to CP-Ti and Ti-6Al-4V.

Alloys

An in vitro model for mineralization of human osteoblast-like cells on implant materials.

An in vitro mineralizing cell-implant system was developed to study osteoblast attachment, secretion of extracellular (ECM) matrix proteins and mineralization. Saos-2 cells were plated on Tivanium (Tiv, Ti-6A1-4V), Zimaloy (Zim, Co-Cr-Mo) and glass disks. The cells were cultured in alpha-MEM medium with 10% fetal bovine serum and 50 microg ml(-1) ascorbic acid. The cultures were analyzed for calcification and for mRNA expression for ECM proteins after 1, 2, 4 and 6 weeks. Calcium content was significantly higher in cells on Tiv, less on Zim and least on glass disks. With the addition of 3 mm beta-glycerophosphate (beta-GP), the cell layer was more calcified on Zim than on Tiv and all substrates had three times more calcium than cultures without beta-GP. All subsequent experiments were performed without beta-GP. Phalloidin immunofluorescence microscopy of the actin-based cytoskeleton at 2 weeks demonstrated nodules composed of multilayered, cobblestone-appearing osteoblasts overlying calcified matrix which was stained with calcein. On Tiv, calcified nodules were connected in a trabecular-like pattern while on Zim, calcification was dispersed throughout the cell layer. Northern blots for alkaline phosphatase, bone sialoprotein, osteocalcin and alpha1(I) procollagen mRNAs were performed at different time points. The amount and pattern of calcification as well as the expression of ECM-mRNAs differed on each implant material. The results indicate that Tiv stimulates the production of more ECM proteins and mineralized matrix than Zim or glass in this osteoblast-like cell/implant culture.

Alloys

Traditional and MLC based dose compensator design for patients with hip prostheses undergoing pelvic radiation therapy.

Perturbations in the dose distribution caused by a hip prosthesis when treating pelvic malignancies can result in unacceptable dose inhomogeneities within the target volume. Our results, obtained by in vivo exit dose measurements with diodes, showed a 55% reduction in the dose at the exit dmax of a lateral 15 MV photon beam after passing through a bilateral cobalt-chrome alloy hip prosthesis. Such an inhomogeneous dose distribution may decrease the curability. Solutions such as treatment techniques to avoid the prosthesis are often not the best choice as the dose to the rectum may be unacceptably high. In this work an alternative method of dose compensator is presented. Two types of dose compensators were designed based on a 3-D treatment planning system and CT images of a pelvic phantom containing a hip prosthesis: one was fabricated from a polyethylene-lead slab in the representation of step fringes and placed on a tray in the path of the beam while the other was produced by the use of several fields shaped with a multileaf collimator. The calculation procedures developed by the authors for generating the compensators are described. Results of film measurements performed in a phantom with and without the compensators in place are discussed.

Alloys