Search PubMed⌕ Search

PubMed · 6687859

A computer program for compression of dynamic studies.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Verdenet, J C Cardot, M Baud, A C Bidet, J Duvernoy, R Bazin, R Bidet. A computer program for compression of dynamic studies.. https://doi.org/10.1016/0010-468x(83)90012-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Improved localization of coronary stents using layer decomposition.

Accurate placement and expansion of coronary stents is hindered by the fact that most stents are only slightly radiopaque and hence difficult to see in typical coronary X-ray images. We propose a new technique for improved image guidance of multiple coronary stent deployment using layer decomposition of coronary X-ray image sequences. We hypothesize that layer decomposition can improve the accuracy of localization of the end of a deployed stent. Layer decomposition is used to obtain good quality images of a stent in vitro. The resultant background-subtracted stent images are embedded into other cine X-ray image sequences to form a database of simulated image sequences. For each simulated sequence, the position of the stent edge is estimated from raw and layer-decomposed images using a small region of the original layer image as a template. Layer decomposition reduced median position errors in 33 of 47 image sequences (70%), including 16 of 18 sequences in which the position errors for raw and layer images differed by 5.0 pixels (0.5 mm) or more. Layer decomposition significantly reduces errors in determination of stent edge location in simulated cine X-ray image sequences.

Cineangiography↗

Central pulmonary artery anatomy in right ventricular outflow tract obstructions.

We reviewed the cine-angiograms of 190 patients with right ventricular outflow tract (RVOT) obstructions for size and anatomy of pulmonary arteries, patent ductus arteriosus (PDA) and major aorto pulmonary collateral arteries (MAPCAs). Patients were grouped into three, Tetralogy of Fallot (TOF) with pulmonary atresia (group 1, N=86), TOF with pulmonary stenosis (group 2, N=97) and 7 cases of pulmonary atresia with intact interventricular septum (group 3). Out of 86 patients in group 1, 49 had PDA alone, 30 had MAPCAs alone, six had both and one had none. In group 2, 31 patients had persistent PDA and one patient had MAPCAS and PDA. A discrete stenosis (DS) of pulmonary artery was seen significantly more in patients with RVOT obstructions associated with PDA compared to patients without PDA (67/84 vs. 5/96). Out of the 84 cases with ducti, 53 had stenosis of the pulmonary artery at the site of ductus insertion. Thus presence of PDA was an important factor in the development of DS. The likely cause of pulmonary artery stenosis in TOF with PDA may be the opposing flows through RVOT and PDA producing a watershed effect at the ductus-pulmonary artery junction. Diffuse hypoplasia of pulmonary arteries (DH) was seen more significantly in RVOT obstructions associated with MAPCAs, compared to other patient groups (19/36 vs. 14/87). These small pulmonary arteries had no discrete stenosis and this diffuse hypoplasia might be the result of inadequate blood flow during intrauterine life [Harikrishnan S, Tharakan J, Titus T, Bhat A, Sivasankaran S, Bimal F, Syam Sunder KR, James, KJ. Central pulmonary artery anatomy in right ventricular outflow tract obstructions. Indian Heart Journal 1997;49:624 (Abstract)[18]].

Cineangiography↗

Accurate measures of left ventricular ejection fraction using electron beam tomography: a comparison with radionuclide angiography, and cine angiography.

BACKGROUND: Quantitative determination of ejection fraction is predicated on precise measurement of end-diastolic and end-systolic volumes of the left ventricle. Contrast enhanced electron beam tomography (EBT), with excellent temporal and spatial resolution, has the potential for highly accurate measures of ejection fraction. METHODS: EBT protocol used a short axis scan of the left ventricle (8-12 levels, apex to base) during infusion of iodinated contrast. To assess the accuracy of the measured left ventricular ejection fraction (LVEF), we compared EBT with first-pass radionuclide angiography (RNA) and cine angiography (CINE). RESULTS: A total of 41 patients (26 men and 15 women) underwent all three tests within 1 week. Resting ejection fraction using each modality was assessed in a linear regression model to assess inter-test correlation with the other two modalities. Correlation between CINE and EBT was high (r = 0.90, intercept 4.67, p < 0.001). Similarly, correlation of CINE and RNA (r = 0.87, intercept -5.48, p < 0.001) and between EBT and RNA (r = 0.87, intercept -4.6, p < 0.001) were high. In a subset of those patients with LVEF < or = 40%, correlation was consistently high between EBT and CINE. However, correlations were poor for the comparisons between RNA and CINE (r = 0.40), and between the RNA and EBT (r = 0.47). The mean differences of measured ejection fractions between each of the imaging modality were small. However, there was only modest agreement between each of the comparisons as measured using 95% confidence interval (CI) on Bland-Altman plots. CONCLUSION: These data indicate that the LVEF results are comparable among EBT, RNA, and CINE and can be used interchangeably to assess ventricular function for LVEF > 40%. For LVEF < or = 40%, we demonstrated some disparate results between cine angiography and RNA and between EBT and RNA, indicating that CINE or EBT may provide more accurate assessment.

Cineangiography↗