Search PubMed⌕ Search

PubMed · 6597161

[Cementation in fixed dentures].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G A Favero. [Cementation in fixed dentures].. https://pubmed.ncbi.nlm.nih.gov/6597161/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Measurement of the migration of a cemented hip prosthesis in an in vitro test.

OBJECTIVE: To develop a method to measure the migration of a cemented hip prosthesis in an in vitro experimental test. DESIGN: A device to measure prosthesis movement relative to bone was designed and fabricated. It was tested using a Lubinus prosthesis (W. Link, Germany) implanted in a composite femur. BACKGROUND: Clinical studies using radiostereophotogrammetry have shown that those cemented hip prosthesis that migrate rapidly in the first two post-operative years are the ones that require early revision. If migration be used as a basis for a pre-clinical test, then it should be possible to screen-out inferior designs before implantation in animal or clinical trials. METHODS: The micromotion measurement device consisted of a 'target' of three spheres arranged in a cruciform structure. Six linear variable displacement transducers were aligned with the spheres so that motion of the prosthesis relative to the bone could be measured. RESULTS: The displacement and rotation of the prosthesis relative to the composite femur was recorded for two million cycles. Relative rapid initial migration was found, followed by a period of steady-state migration. Distal migration (called 'subsidence' in this paper) of up to 0.1 mm was measured; however the variability in absolute prosthesis migration was very high despite efforts to ensure that all extraneous factors were minimised. In the majority of cases, the prostheses migrated medially, distally and anteriorly. The absolute subsidence, and its variability, were similar to that recorded clinically. CONCLUSIONS: A method has been designed and tested which measures prosthesis migration in an experimental test. It provides a basis for a pre-clinical testing standard. Relevance. Hip prostheses need to be tested experimentally before implantation. However, no reliable test exists for such experimental tests. Rapid migration of a cemented prosthesis relative to bone has been shown in vivo to correlate with early failure, and in this paper a method to make such migration measurements in vitro is described and tested.

Cementation↗

An in vitro study into the effect of the ferrule preparation on the fracture resistance of crowned teeth incorporating prefabricated post and composite core restorations.

AIM: This in vitro study investigated the effect of a ferrule preparation on the fracture resistance of crowned central incisors incorporating a prefabricated post (Parapost) cemented with Panavia-Ex and with a composite core. METHODOLOGY: The test group consisted of 10 post crowned natural central incisor teeth with a 2-mm wide ferrule preparation, whilst the control group of 10 teeth had no ferrule. The specimens were mounted on a Lloyd universal testing machine and a compressive load was applied at an angle of 135 degrees to the palatal surface of the crown until failure occurred. RESULTS: In both groups, failure occurred at higher loads compared with previous studies. The mean failure load was 1218 N for the unferruled group and 1407 N for the ferruled group. Statistical analysis showed no significant difference between the groups. CONCLUSIONS: Under the conditions of this study, when composite cement and core materials are utilized with a Parapost prefabricated system in vitro the additional use of a ferrule preparation has no benefit in terms of resistance to fracture.

Cementation↗

Marginal adaptation of cast partial crowns made of pure titanium and a gold alloy under influence of a manual burnishing technique.

The aim of this study was to determine the marginal adaptation of partial crowns from pure titanium and a gold alloy after two different cementation techniques. Forty freshly extracted human molars were prepared and randomly divided in four groups. Two groups were restored with partial crowns using the gold alloy Degulor M*. In one group, the crowns were fixed on the tooth by using a zinc phosphate cement. In the other group the margins were additionally burnished by using a hand burnisher No. 660. In the other two groups, partial crowns from pure titanium were cemented in the same way. The marginal quality was determined by quantitative margin analysis in the SEM using a replica technique. Partial crowns from a gold alloy showed significantly (P < 0.05) more margin quality A (vertical marginal discrepancy < 50 microm) while partial crowns from pure titanium had significantly (P < 0.05) more margin quality B (vertical marginal discrepancy 50-100 microm) and over-extended margins (quality D). No significant (P < 0.05) difference was found between the conventional cementation technique and the technique with manual burnishing in both material groups.

Cementation↗