Abstract

We evaluated a new exercise-testing system (Beckman Horizon MMC), incorporating a microprocessor that controls the acquisition of data, corrects for time delays, applies calibration factors, ensures quality control, and presents results in a variety of formats. Precision of measurements of ventilation (VE) and mixed expired gas concentrations was high. In steady-state exercise (n = 100) VO2 was measured with a precision (+/- SD) of 66 ml/min (4.3%), (r = 0.991); there was a small (4.62%) systematic underestimation of VCO2, but precision was comparable with VO2, with SD being 67 ml/min (4.55%) (r = 0.993). Good agreement was obtained between measurements made in progressive incremental exercise in healthy subjects with correlation coefficients of 0.997 for VE, 0.995 for VO2, and 0.994 for VCO2. Agreement in patients with cardiorespiratory disorders (n = 10) was similar, except in three patients in whom a variable pattern of breathing limited strict comparisons. Comparison with a breath-by-breath analysis system (n = 5) showed that rapid changes in VE, VCO2, and VO2 were followed accurately; the half time for a change in VO2 was not systematically different between the two systems (SD, 3.34 s, r = 0.951). The incorporation of microprocessor-controlled calibration procedures, which are simple to carry out frequently, was judged to be an important feature of this system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N L Jones. 1984. Evaluation of a microprocessor-controlled exercise testing system.. https://doi.org/10.1152/jappl.1984.57.5.1312

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Predictors of prognosis in severe chronic heart failure.

A total of 127 patients with chronic heart failure referred to our exercise laboratory were studied retrospectively to identify parameters predictive of prognosis. Patients were followed for a mean of 14.6 months. The group as a whole had severe ventricular dysfunction with a median ejection fraction of 17% and a median peak rate of oxygen consumption of 13.7 ml/kg/min. During the follow-up period 23 patients (18%) died and 18 (14%) underwent cardiac transplantation. The effect of the following variables on outcome (death or transplantation) were examined: age, cause of heart failure, cardiothoracic ratio on chest radiography, left ventricular end-systolic dimension on echocardiography, left ventricular ejection fraction on radionuclide ventriculography, mean dose of diuretic, plasma sodium and urea concentrations, and peak oxygen consumption during exercise. Although all variables except cause of heart failure affected outcome on univariate analysis, multivariate analysis identified three variables that were statistically significant and independent predictors of outcome. In order of importance these were plasma sodium level, left ventricular ejection fraction and peak oxygen consumption. Even in this group of patients with severe heart failure, these variables were predictive of outcome.

Exercise Test